SIM800L GPS/GPRS AT Commands
Last updated
Last updated
SIM800 Series_AT Command Manual_V1.09 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 2 2015-08-03 Document Title: SIM800 Series AT Command Manual Version: 1.09 Date: 2015-08-03 Status: Release Document Control ID: SIM800 Series_AT Command Manual_V1.09 General Notes SIMCom offers this information as a service to its customers, to support application and engineering efforts that use the products designed by SIMCom. The information provided is based upon requirements specifically provided to SIMCom by the customers. SIMCom has not undertaken any independent search for additional relevant information, including any information that may be in the customer’s possession. Furthermore, system validation of this product designed by SIMCom within a larger electronic system remains the responsibility of the customer or the customer’s system integrator. All specifications supplied herein are subject to change. Copyright This document contains proprietary technical information which is the property of Shanghai SIMCom Wireless Solutions Ltd, copying of this document and giving it to others and the using or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. All rights reserved in the event of grant of a patent or the registration of a utility model or design. All specification supplied herein are subject to change without notice at any time. Copyright © Shanghai SIMCom Wireless Solutions Ltd. 2015 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 3 2015-08-03 Contents Version History.........................................................................................14 1 Introduction............................................................................................22 1.1 Scope of the document .......................................................................................22 1.2 Related documents..............................................................................................22 1.3 Conventions and abbreviations ..........................................................................22 1.4 AT Command syntax ..........................................................................................22 1.4.1 Basic syntax ...................................................................................................................23 1.4.2 S Parameter syntax.........................................................................................................23 1.4.3 Extended Syntax.............................................................................................................23 1.4.4 Combining AT commands on the same Command line.................................................23 1.4.5 Entering successive AT commands on separate lines.....................................................24 1.5 Supported character sets.....................................................................................24 1.6 Flow control .......................................................................................................24 1.6.1 Software flow control (XON/XOFF flow control).........................................................24 1.6.2 Hardware flow control (RTS/CTS flow control)............................................................25 1.7 Definitions ..........................................................................................................25 1.7.1 Parameter Saving Mode .................................................................................................25 1.7.2 Max Response Time.......................................................................................................26 2 AT Commands According to V.25TER ................................................27 2.1 Overview of AT Commands According to V.25TER .........................................27 2.2 Detailed Description of AT Commands According to V.25TER ........................28 2.2.1 A/ Re-issues the Last Command Given.......................................................................28 2.2.2 ATA Answer an Incoming Call....................................................................................28 2.2.3 ATD Mobile Originated Call to Dial A Number..........................................................29 2.2.4 ATD> Originate Call to Phone Number in Current Memory................................31 2.2.5 ATD> Originate Call to Phone Number in Memory Which Corresponds to Field ...............................................................................................................................32 2.2.6 ATDL Redial Last Telephone Number Used...............................................................34 2.2.7 ATE Set Command Echo Mode ..................................................................................35 2.2.8 ATH Disconnect Existing Connection.........................................................................35 2.2.9 ATI Display Product Identification Information .........................................................35 2.2.10 ATL Set Monitor speaker loudness............................................................................36 2.2.11 ATM Set Monitor Speaker Mode ..............................................................................36 2.2.12 +++ Switch from Data Mode or PPP Online Mode to Command Mode ..................36 2.2.13 ATO Switch from Command Mode to Data Mode....................................................37 2.2.14 ATP Select Pulse Dialling..........................................................................................37 2.2.15 ATQ Set Result Code Presentation Mode..................................................................38 2.2.16 ATS0 Set Number of Rings before Automatically Answering the Call.....................38 2.2.17 ATS3 Set Command Line Termination Character .....................................................39 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 4 2015-08-03 2.2.18 ATS4 Set Response Formatting Character ................................................................39 2.2.19 ATS5 Set Command Line Editing Character.............................................................40 2.2.20 ATS6 Pause Before Blind Dialling............................................................................41 2.2.21 ATS7 Set Number of Seconds to Wait for Connection Completion..........................41 2.2.22 ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in Dial String of D Command .....................................................................................................42 2.2.23 ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier..............42 2.2.24 ATT Select Tone Dialing ...........................................................................................43 2.2.25 ATV TA Response Format .......................................................................................43 2.2.26 ATX Set CONNECT Result Code Format and Monitor Call Progress .....................44 2.2.27 ATZ Reset Default Configuration .............................................................................45 2.2.28 AT&C Set DCD Function Mode ...............................................................................45 2.2.29 AT&D Set DTR Function Mode................................................................................46 2.2.30 AT&F Factory Defined Configuration ......................................................................46 2.2.31 AT&V Display Current Configuration ......................................................................47 2.2.32 AT&W Store Active Profile ......................................................................................47 2.2.33 AT+GCAP Request Complete TA Capabilities List ..................................................49 2.2.34 AT+GMI Request Manufacturer Identification .........................................................49 2.2.35 AT+GMM Request TA Model Identification ............................................................50 2.2.36 AT+GMR Request TA Revision Identification of Software Release.........................50 2.2.37 AT+GOI Request Global Object Identification.........................................................51 2.2.38 AT+GSN Request TA Serial Number Identification (IMEI) .....................................51 2.2.39 AT+ICF Set TE-TA Control Character Framing........................................................52 2.2.40 AT+IFC Set TE-TA Local Data Flow Control ..........................................................53 2.2.41 AT+IPR Set TE-TA Fixed Local Rate .......................................................................54 2.2.42 AT+HVOIC Disconnect Voice Call Only..................................................................55 3 AT Commands According to 3GPP TS 27.007.....................................56 3.1 Overview of AT Command According to 3GPP TS 27.007 ...............................56 3.2 Detailed Descriptions of AT Command According to 3GPP TS 27.007 ............57 3.2.1 AT+CACM Accumulated Call Meter (ACM) Reset or Query....................................57 3.2.2 AT+CAMM Accumulated Call Meter Maximum (ACM max) Set or Query .............58 3.2.3 AT+CAOC Advice of Charge .....................................................................................59 3.2.4 AT+CBST Select Bearer Service Type........................................................................60 3.2.5 AT+CCFC Call Forwarding Number and Conditions Control....................................61 3.2.6 AT+CCWA Call Waiting Control ................................................................................63 3.2.7AT+CEER Extended Error Report ...............................................................................64 3.2.8 AT+CGMI Request Manufacturer Identification ........................................................67 3.2.9 AT+CGMM Request Model Identification..................................................................67 3.2.10 AT+CGMR Request TA Revision Identification of Software Release......................68 3.2.11 AT+CGSN Request Product Serial Number Identification (Identical with +GSN)...68 3.2.12 AT+CSCS Select TE Character Set...........................................................................69 3.2.13 AT+CSTA Select Type of Address ............................................................................70 3.2.14 AT+CHLD Call Hold and Multiparty........................................................................70 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 5 2015-08-03 3.2.15 AT+CIMI Request International Mobile Subscriber Identity....................................71 3.2.16 AT+CLCC List Current Calls of ME.........................................................................72 3.2.17 AT+CLCK Facility Lock...........................................................................................73 3.2.18 AT+CLIP Calling Line Identification Presentation ...................................................75 3.2.19 AT+CLIR Calling Line Identification Restriction.....................................................76 3.2.20 AT+CMEE Report Mobile Equipment Error.............................................................77 3.2.21 AT+COLP Connected Line Identification Presentation ............................................78 3.2.22 AT+COPS Operator Selection...................................................................................80 3.2.23 AT+CPAS Phone Activity Status...............................................................................81 3.2.24 AT+CPBF Find Phonebook Entries...........................................................................82 3.2.25 AT+CPBR Read Current Phonebook Entries ............................................................83 3.2.26 AT+CPBS Select Phonebook Memory Storage.........................................................84 3.2.27 AT+CPBW Write Phonebook Entry..........................................................................85 3.2.28 AT+CPIN Enter PIN..................................................................................................86 3.2.29 AT+CPWD Change Password...................................................................................87 3.2.30 AT+CR Service Reporting Control ...........................................................................88 3.2.31 AT+CRC Set Cellular Result Codes for Incoming Call Indication ...........................89 3.2.32 AT+CREG Network Registration..............................................................................90 3.2.33 AT+CRLP Select Radio Link Protocol Parameters ...................................................92 3.2.34 AT+CRSM Restricted SIM Access ...........................................................................92 3.2.35 AT+CSQ Signal Quality Report ................................................................................93 3.2.36 AT+VTD Tone Duration............................................................................................94 3.2.37 AT+VTS DTMF and Tone Generation......................................................................95 3.2.38 AT+CMUX Multiplexer Control...............................................................................96 3.2.39 AT+CNUM Subscriber Number................................................................................97 3.2.40 AT+CPOL Preferred Operator List............................................................................98 3.2.41 AT+COPN Read Operator Names.............................................................................99 3.2.42 AT+CFUN Set Phone Functionality........................................................................100 3.2.43 AT+CCLK Clock.....................................................................................................101 3.2.44 AT+CSIM Generic SIM Access ..............................................................................101 3.2.45 AT+CALM Alert Sound Mode................................................................................102 3.2.46 AT+CALS Alert Sound Select.................................................................................103 3.2.47 AT+CRSL Ringer Sound Level...............................................................................104 3.2.48 AT+CLVL Loud Speaker Volume Level .................................................................104 3.2.49 AT+CMUT Mute Control........................................................................................105 3.2.50 AT+CPUC Price Per Unit and Currency Table........................................................106 3.2.51 AT+CCWE Call Meter Maximum Event ................................................................107 3.2.52 AT+CBC Battery Charge.........................................................................................108 3.2.53 AT+CUSD Unstructured Supplementary Service Data...........................................108 3.2.54 AT+CSSN Supplementary Services Notification....................................................109 4 AT Commands According to 3GPP TS 27.005...................................112 4.1 Overview of AT Commands According to 3GPP TS 27.005............................112 4.2 Detailed Descriptions of AT Commands According to 3GPP TS 27.005.........112 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 6 2015-08-03 4.2.1 AT+CMGD Delete SMS Message.............................................................................112 4.2.2 AT+CMGF Select SMS Message Format .................................................................113 4.2.3 AT+CMGL List SMS Messages from Preferred Store..............................................114 4.2.4 AT+CMGR Read SMS Message...............................................................................117 4.2.5 AT+CMGS Send SMS Message................................................................................120 4.2.6 AT+CMGW Write SMS Message to Memory ..........................................................121 4.2.7 AT+CMSS Send SMS Message from Storage ..........................................................123 4.2.8 AT+CNMI New SMS Message Indications ..............................................................124 4.2.9 AT+CPMS Preferred SMS Message Storage ............................................................126 4.2.10 AT+CRES Restore SMS Settings............................................................................127 4.2.11 AT+CSAS Save SMS Settings ................................................................................128 4.2.12 AT+CSCA SMS Service Center Address ................................................................129 4.2.13 AT+CSCB Select Cell Broadcast SMS Messages...................................................130 4.2.14 AT+CSDH Show SMS Text Mode Parameters .......................................................131 4.2.15 AT+CSMP Set SMS Text Mode Parameters ...........................................................132 4.2.16 AT+CSMS Select Message Service.........................................................................133 5 AT Commands for SIM Application Toolkit ......................................135 5.1 Overview ..........................................................................................................135 5.2 Detailed Descriptions of Commands................................................................135 5.2.1 AT+STKTRS STK Terminal Response.....................................................................135 5.2.2 AT+STKENVS STK Envelope Command................................................................136 5.2.3 AT+STKCALL STK call setup .................................................................................137 5.2.4 AT+STKSMS STK SMS delivery.............................................................................138 5.2.5 AT+STKSS STK SS setup ........................................................................................138 5.2.6 AT+STKUSSD STK USSD setup.............................................................................139 5.2.7 AT+STKDTMF STK sending DTMF .......................................................................139 5.2.8 +STKPCI STK Proactive Command Indication .......................................................140 5.2.9 AT+STKMENU STK Main menu command ............................................................141 5.2.10 AT+STKPCIS STK URC switch command ............................................................141 6 AT Commands Special for SIMCom ..................................................143 6.1 Overview ..........................................................................................................143 6.2 Detailed Descriptions of Commands................................................................145 6.2.1 AT+SIDET Change the Side Tone Gain Level.......................................................145 6.2.2 AT+CPOWD Power off............................................................................................146 6.2.3 AT+SPIC Times Remained to Input SIM PIN/PUK.................................................146 6.2.4 AT+CMIC Change the Microphone Gain Level.......................................................146 6.2.5 AT+CALA Set Alarm Time......................................................................................148 6.2.6 AT+CALD Delete Alarm..........................................................................................149 6.2.7 AT+CADC Read ADC .............................................................................................149 6.2.8 AT+CSNS Single Numbering Scheme .....................................................................150 6.2.9 AT+CDSCB Reset Cell Broadcast............................................................................151 6.2.10 AT+CMOD Configure Alternating Mode Calls .....................................................151 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 7 2015-08-03 6.2.11 AT+CFGRI Indicate RI When Using URC ............................................................151 6.2.12 AT+CLTS Get Local Timestamp............................................................................152 6.2.13 AT+CLDTMF Local DTMF Tone Generation.......................................................154 6.2.14 AT+CDRIND CS Voice/Data Call Termination Indication ...................................155 6.2.15 AT+CSPN Get Service Provider Name from SIM ..................................................156 6.2.16 AT+CCVM Get and Set the Voice Mail Number on the SIM .................................156 6.2.17 AT+CBAND Get and Set Mobile Operation Band .................................................157 6.2.18 AT+CHF Configure Hands Free Operation.............................................................158 6.2.19 AT+CHFA Swap the Audio Channels .....................................................................159 6.2.20 AT+CSCLK Configure Slow Clock ........................................................................160 6.2.21 AT+CENG Switch on or off Engineering Mode .....................................................161 6.2.22 AT+SCLASS0 Store Class 0 SMS to SIM When Received Class 0 SMS ..............163 6.2.23 AT+CCID Show ICCID ..........................................................................................164 6.2.24 AT+CMTE Set Critical Temperature Operating Mode or Query Temperature......164 6.2.25 AT+CMGDA Delete All SMS................................................................................165 6.2.26 AT+STTONE Play SIM Toolkit Tone....................................................................166 6.2.27 AT+SIMTONE Generate Specifically Tone...........................................................167 6.2.28 AT+CCPD Enable or Disable Alpha String............................................................168 6.2.29 AT+CGID Get SIM Card Group Identifier.............................................................168 6.2.30 AT+MORING Show State of Mobile Originated Call............................................169 6.2.31 AT+CMGHEX Enable or Disable Sending Non-ASCII Character SMS ...............170 6.2.32 AT+CCODE Configure SMS Code Mode..............................................................170 6.2.33 AT+CIURC Enable or Disable Initial URC Presentation .......................................171 6.2.34 AT+CPSPWD Change PS Super Password ............................................................172 6.2.35 AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications.................172 6.2.36 AT+CGMSCLASS Change GPRS Multislot Class ................................................173 6.2.37 AT+CDEVICE View Current Flash Device Type..................................................174 6.2.38 AT+CCALR Call Ready Query ..............................................................................174 6.2.39 AT+GSV Display Product Identification Information.............................................174 6.2.40 AT+SGPIO Control the GPIO.................................................................................175 6.2.41 AT+SPWM Generate the Pulse-Width-Modulation ................................................176 6.2.42 AT+ECHO Echo Cancellation Control ...................................................................176 6.2.43 AT+CAAS Control Auto Audio Switch ..................................................................177 6.2.44 AT+SVR Configure Voice Coding Type for Voice Calls.........................................178 6.2.45 AT+GSMBUSY Reject Incoming Call....................................................................179 6.2.46 AT+CEMNL Set the List of Emergency Number ...................................................180 6.2.47 AT*CELLLOCK Set the List of ARFCN Which Needs to Be Locked...................181 6.2.48 AT+SLEDS Set the Timer Period of Net Light .......................................................182 6.2.49 AT+CBUZZERRING Use the Buzzer Sound as the Incoming Call Ring...............183 6.2.50 AT+CEXTERNTONE Close or Open the Microphone...........................................183 6.2.51 AT+CNETLIGHT Close the Net Light or Open It to Shining ................................184 6.2.52 AT+CWHITELIST Set the White List ....................................................................185 6.2.53 AT+CSDT Switch on or off Detecting SIM Card...................................................186 6.2.54 AT+CSMINS SIM Inserted Status Reporting.........................................................186 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 8 2015-08-03 6.2.55 AT+CSGS Netlight Indication of GPRS Status .....................................................187 6.2.56 AT+CMICBIAS Close or Open the MICBIAS ......................................................188 6.2.57 AT+DTAM Set TTS and RECORD Play Mode in Call .........................................189 6.2.58 AT+SJDR Set Jamming Detection Function ...........................................................189 6.2.59 AT+CPCMCFG Set PCM Parameter ......................................................................191 6.2.60 AT+CPCMSYNC Set PCM Sync Parameter...........................................................192 6.2.61 AT+CANT Antenna Detecting ................................................................................193 6.2.62 AT+CAGCSET Close or Open AGC Function .......................................................194 6.2.63 AT+SD2PCM SD and PCM Switch Function.........................................................194 6.2.64 AT+SKPD Keypad Detecting Function...................................................................195 6.2.65 AT+SIMTONEX Custom Tones ...............................................................................196 6.2.66 AT+CROAMING Roaming State..............................................................................197 6.2.67 AT+CNETSCAN Perform a Net Survey to Show All the Cells’ Information...........197 6.2.68 AT+CMNRP Dual Serial Port Feature....................................................................198 6.2.69 AT+CEGPRS Switch on or off EDGE ...................................................................199 6.2.70 AT+CGPIO Control the GPIO by PIN Index ..........................................................200 6.2.71 AT+CMEDPLAY Play Audio File ..........................................................................201 6.2.72 AT+CMEDIAVOL Control the Volume when Playing Audio File..........................202 6.2.73 AT+SNDLEVEL Set the Sound Level of Special AT Command ............................202 6.2.74 AT+ECHARGE Charge Control.............................................................................203 6.2.75 AT+SIMTIMER Modify the Poll Interval Time Requested by SIM Card .............204 6.2.76 AT+SPE Speech Enhancement Control..................................................................204 6.2.77 AT+CCONCINDEX Report Concatenated SMS Index..........................................205 6.2.78 AT+SDMODE SD Mode Switch Function .............................................................205 6.2.79 AT+SRSPT Control SMS Retransmission..............................................................206 7 AT Commands for GPRS Support ......................................................208 7.1 Overview of AT Commands for GPRS Support...............................................208 7.2 Detailed Descriptions of AT Commands for GPRS Support............................208 7.2.1 AT+CGATT Attach or Detach from GPRS Service ..................................................208 7.2.2 AT+CGDCONT Define PDP Context.......................................................................209 7.2.3 AT+CGQMIN Quality of Service Profile (Minimum Acceptable) ...........................210 7.2.4 AT+CGQREQ Quality of Service Profile (Requested) .............................................211 7.2.5 AT+CGACT PDP Context Activate or Deactivate....................................................213 7.2.6 AT+CGDATA Enter Data State .................................................................................214 7.2.7 AT+CGPADDR Show PDP Address .........................................................................214 7.2.8 AT+CGCLASS GPRS Mobile Station Class.............................................................215 7.2.9 AT+CGEREP Control Unsolicited GPRS Event Reporting......................................216 7.2.10 AT+CGREG Network Registration Status ..............................................................217 7.2.11 AT+CGSMS Select Service for MO SMS Messages ..............................................218 8 AT Commands for TCPIP Application Toolkit ..................................220 8.1 Overview ..........................................................................................................220 8.2 Detailed Descriptions of Commands................................................................221 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 9 2015-08-03 8.2.1 AT+CIPMUX Start Up Multi-IP Connection ............................................................221 8.2.2 AT+CIPSTART Start Up TCP or UDP Connection...................................................221 8.2.3 AT+CIPSEND Send Data Through TCP or UDP Connection...................................223 8.2.4 AT+CIPQSEND Select Data Transmitting Mode .....................................................225 8.2.5 AT+CIPACK Query Previous Connection Data Transmitting State..........................226 8.2.6 AT+CIPCLOSE Close TCP or UDP Connection .....................................................227 8.2.7 AT+CIPSHUT Deactivate GPRS PDP Context ........................................................227 8.2.8 AT+CLPORT Set Local Port.....................................................................................228 8.2.9 AT+CSTT Start Task and Set APN, USER NAME, PASSWORD...........................229 8.2.10 AT+CIICR Bring Up Wireless Connection with GPRS or CSD .............................230 8.2.11 AT+CIFSR Get Local IP Address............................................................................230 8.2.12 AT+CIPSTATUS Query Current Connection Status ...............................................231 8.2.13 AT+CDNSCFG Configure Domain Name Server...................................................232 8.2.14 AT+CDNSGIP Query the IP Address of Given Domain Name...............................233 8.2.15 AT+CIPHEAD Add an IP Head at the Beginning of a Package Received..............234 8.2.16 AT+CIPATS Set Auto Sending Timer .....................................................................234 8.2.17 AT+CIPSPRT Set Prompt of ‘>’ When Module Sends Data...................................235 8.2.18 AT+CIPSERVER Configure Module as Server ......................................................236 8.2.19 AT+CIPCSGP Set CSD or GPRS for Connection Mode ........................................237 8.2.20 AT+CIPSRIP Show Remote IP Address and Port When Received Data ................238 8.2.21 AT+CIPDPDP Set Whether to Check State of GPRS Network Timing ..................239 8.2.22 AT+CIPMODE Select TCPIP Application Mode....................................................239 8.2.23 AT+CIPCCFG Configure Transparent Transfer Mode............................................240 8.2.24 AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data.....241 8.2.25 AT+CIPUDPMODE UDP Extended Mode.............................................................242 8.2.26 AT+CIPRXGET Get Data from Network Manually ...............................................243 8.2.27 AT+CIPSCONT Save TCPIP Application Context .................................................245 8.2.28 AT+CIPRDTIMER Set Remote Delay Timer ........................................................246 8.2.29 AT+CIPSGTXT Select GPRS PDP context ...........................................................247 8.2.30 AT+CIPTKA Set TCP Keepalive Parameters.........................................................248 9 AT Commands for IP Application.......................................................249 9.1 Overview ..........................................................................................................249 9.2 Detailed Descriptions of Commands................................................................249 9.2.1 AT+SAPBR Bearer Settings for Applications Based on IP.......................................249 10 AT Commands for PING Support .....................................................251 10.1 Overview ........................................................................................................251 10.2 Detailed Descriptions of Commands..............................................................251 10.2.1 AT+CIPPING PING Request..................................................................................251 10.2.2 AT+CIPCTL Set the Mode When Receiving an IP Packet .....................................252 10.2.3 AT+CIPFLT Set the Rules of IP Filter ....................................................................253 10.2.4 AT+CIPBEIPING Set the Module to be PING or Not............................................254 11 AT Commands for HTTP Application ..............................................256 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 10 2015-08-03 11.1 Overview ........................................................................................................256 11.2 Detailed Descriptions of Commands..............................................................256 11.2.1 AT+HTTPINIT Initialize HTTP Service .................................................................256 11.2.2 AT+HTTPTERM Terminate HTTP Service ............................................................257 11.2.3 AT+HTTPPARA Set HTTP Parameters Value ........................................................257 11.2.4 AT+HTTPDATA Input HTTP Data .........................................................................259 11.2.5 AT+HTTPACTION HTTP Method Action .............................................................259 11.2.6 AT+HTTPREAD Read the HTTP Server Response................................................261 11.2.7 AT+HTTPSCONT Save HTTP Application Context ..............................................262 11.2.8 AT+HTTPSTATUS Read HTTP Status ...................................................................263 11.2.9 AT+HTTPHEAD Read the HTTP Header Information of Server Response...........264 12 AT Commands for FTP Application .................................................265 12.1 Overview ........................................................................................................265 12.2 Detailed Descriptions of Commands..............................................................266 12.2.1 AT+FTPPORT Set FTP Control Port ......................................................................266 12.2.2 AT+FTPMODE Set Active or Passive FTP Mode ..................................................266 12.2.3 AT+FTPTYPE Set the Type of Data to Be Transferred...........................................267 12.2.4 AT+FTPPUTOPT Set FTP Put Type .......................................................................268 12.2.5 AT+FTPCID Set FTP Bearer Profile Identifier.......................................................268 12.2.6 AT+FTPREST Set Resume Broken Download .......................................................269 12.2.7 AT+FTPSERV Set FTP Server Address ..................................................................269 12.2.8 AT+FTPUN Set FTP User Name ............................................................................270 12.2.9 AT+FTPPW Set FTP Password...............................................................................271 12.2.10 AT+FTPGETNAME Set Download File Name ....................................................272 12.2.11 AT+FTPGETPATH Set Download File Path.........................................................272 12.2.12 AT+FTPPUTNAME Set Upload File Name .........................................................273 12.2.13 AT+FTPPUTPATH Set Upload File Path..............................................................273 12.2.14 AT+FTPGET Download File ................................................................................274 12.2.15 AT+FTPPUT Set Upload File ...............................................................................275 12.2.16 AT+FTPSCONT Save FTP Application Context ..................................................276 12.2.17 AT+FTPDELE Delete Specified File in FTP Server.............................................277 12.2.18 AT+FTPSIZE Get the Size of Specified File in FTP Server .................................278 12.2.19 AT+FTPSTATE Get the FTP State ........................................................................279 12.2.20 AT+FTPEXTPUT Extend Upload File.....................................................................279 12.2.21 AT+FTPMKD Make Directory on the Remote Machine ......................................280 12.2.22 AT+FTPRMD Remove Directory on the Remote Machine ..................................281 12.2.23 AT+FTPLIST List Contents of Directory on the Remote Machine.......................281 12.2.24 AT+FTPGETTOFS Download File and Save in File System ...............................282 12.2.25 AT+FTPPUTFRMFS Upload File from File System. ...........................................283 12.2.26 AT+FTPEXTGET Extend Download File ............................................................285 12.2.27 AT+FTPFILEPUT Load File in RAM from File System then Upolad with FTPPUT ................................................................................................................................286 12.2.28 AT+FTPQUIT Quit Current FTP Session .............................................................287 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 11 2015-08-03 13 AT Commands for GSM Location Application ................................288 13.1 Overview ........................................................................................................288 13.2 Detailed Descriptions of Commands..............................................................288 13.2.1 AT+CIPGSMLOC GSM Location and Time ............................................................288 14 AT Commands for Email Application...............................................290 14.1 Overview ........................................................................................................290 14.2 Detailed Descriptions of Commands..............................................................291 14.2.1 AT+EMAILCID Set Email Bearer Profile Identifier..............................................291 14.2.2 AT+EMAILTO Set Timeout Value of SMTP/POP3 Server Response ..................291 14.2.3 AT+SMTPSRV Set SMTP Server Address and Port..............................................292 14.2.4 AT+SMTPAUTH Set User Name and Password for SMTP Authentication..........293 14.2.5 AT+SMTPFROM Set Sender Address and Name ..................................................294 14.2.6 AT+SMTPRCPT Set the Email Recipient(TO/CC/BCC) Address and Name........295 14.2.7 AT+SMTPSUB Set the Email Subject....................................................................296 14.2.8 AT+SMTPBODY Set the Email Body ...................................................................296 14.2.9 AT+SMTPFILE Set the Email Attachment ............................................................297 14.2.10 AT+SMTPSEND Send the Email.........................................................................298 14.2.11 AT+SMTPFT Transfer the Email Attachment ......................................................299 14.2.12 AT+SMTPCS Set the Email Charset ....................................................................300 14.2.13 AT+POP3SRV Set POP3 Server and Account .....................................................301 14.2.14 AT+POP3IN Log in POP3 Server ........................................................................302 14.2.15 AT+POP3NUM Get Email Number and Total Size..............................................302 14.2.16 AT+POP3LIST Get the Specific Email Size ........................................................303 14.2.17 AT+POP3UIDL Get the Specific Email Unique-id ..............................................304 14.2.18 AT+POP3CMD Get Multi-line Response.............................................................305 14.2.19 AT+POP3READ Read Multi-line Response ........................................................307 14.2.20 AT+POP3DEL Mark the Specific Email to Delete...............................................308 14.2.21 AT+POP3RSET Unmark the Emails that Be Marked as Deleted.........................309 14.2.22 AT+POP3OUT Log Out POP3 Server..................................................................310 15 AT Commands for MMS Application...............................................311 15.1 Overview ........................................................................................................311 15.2 Detailed Descriptions of Commands..............................................................312 15.2.1 AT+CMMSCURL Set the URL of the MMS Center..............................................312 15.2.2 AT+CMMSPROTO Set the Protocol Parameter and MMS Proxy .........................312 15.2.3 AT+CMMSCID Set the Network Parameters for MMS.........................................313 15.2.4 AT+CMMSSENDCFG Set the Parameters for Sending MMS ..............................314 15.2.5 AT+CMMSEDIT Enter or Exit Edit Mode.............................................................315 15.2.6 AT+CMMSDOWN Download the File Data or Title from UART.........................316 15.2.7 AT+CMMSDELFILE Delete the File of the Edited MMS by File Index...............317 15.2.8 AT+CMMSSEND Start MMS Sending..................................................................318 15.2.9 AT+CMMSRECP Add Recipients..........................................................................319 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 12 2015-08-03 15.2.10 AT+CMMSCC Add Copy Recipients...................................................................319 15.2.11 AT+CMMSBCC Add Secret Recipients...............................................................320 15.2.12 AT+CMMSDELRECP Delete Recipients ............................................................321 15.2.13 AT+CMMSDELCC Delete Copy Recipients .......................................................321 15.2.14 AT+CMMSDELBCC Delete Secret Recipients ...................................................322 15.2.15 AT+CMMSRECV Receive MMS ........................................................................323 15.2.16 AT+CMMSVIEW Get the MMS into Buffer and Show the Information.............324 15.2.17 AT+CMMSREAD Read the Given File of the MMS in the Buffer......................325 15.2.18 AT+CMMSRDPUSH Read the Information of the MMS PUSH Message..........325 15.2.19 AT+CMMSUA Set User Agent ............................................................................327 15.2.20 AT+CMMSPROFILE Set User Agent Profile ......................................................328 15.2.21 AT+CMMSTIMEOUT Set MMS Timeout...........................................................328 15.2.22 AT+CMMSSTATUS Get MMS Status ................................................................329 15.2.23 AT+CMMSINIT Initialize MMS Function...........................................................330 15.2.24 AT+CMMSTERM Exit MMS Function ...............................................................330 15.2.25 AT+CMMSSCONT Save MMS Context..............................................................331 16 AT Commands for DDET Application..............................................333 16.1 Overview ........................................................................................................333 16.2 Detailed Descriptions of Commands..............................................................333 16.2.1 AT+DDET DTMF Detection Control.....................................................................333 17 AT Commands for RECORD Application........................................335 17.1 Overview ........................................................................................................335 17.2 Detailed Descriptions of Commands..............................................................335 17.2.1 AT+CREC Record Operation..................................................................................335 17.2.2 AT+CRECORD Record and Send Data to UART...................................................338 18 AT Commands for TTS Application .................................................340 18.1 Overview ........................................................................................................340 18.2 Detailed Descriptions of Commands..............................................................340 18.2.1 AT+CTTS TTS Operation.......................................................................................340 18.2.2 AT+CTTSPARAM Set Parameters of the TTS Playing..........................................341 18.2.3 AT+CTTSRING Enable/Disable TTS Play During Incoming Call Ring................342 19 Supported Unsolicited Result Codes .................................................343 19.1 Summary of CME ERROR Codes .................................................................343 19.2 Summary of CMS ERROR Codes .................................................................346 19.3 Summary of Unsolicited Result Codes ..........................................................350 20 AT Commands Examples ..................................................................355 20.1 Profile Commands..........................................................................................355 20.2 SIM Commands..............................................................................................356 20.3 General Commands ........................................................................................358 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 13 2015-08-03 20.4 Call Control Commands.................................................................................359 20.5 SIM Toolkit Commands .................................................................................361 20.6 Audio Commands ...........................................................................................361 20.7 SMS Commands.............................................................................................361 20.8 GPRS Commands...........................................................................................362 20.9 TCPIP Commands ..........................................................................................364 20.10 IP Commands ...............................................................................................365 20.11 PING Commands..........................................................................................365 20.12 HTTP and FTP Commands ..........................................................................366 20.13 GSM Location Commands...........................................................................366 20.14 EMAIL Commands ......................................................................................367 20.15 MMS Commands .........................................................................................367 20.16 DDET Commands ........................................................................................368 20.17 RECORD Commands...................................................................................370 20.18 TTS Commands............................................................................................371 21 ATC Differences among SIM800 Series...........................................373 21.1 AT+SIDET......................................................................................................373 21.2 AT+CMIC.......................................................................................................373 21.3 AT+CBAND ...................................................................................................374 21.4 AT+CHFA.......................................................................................................374 21.5 AT+SGPIO......................................................................................................375 21.6 AT+SJDR........................................................................................................375 21.7 AT+CREC.......................................................................................................376 21.8 AT+CTTSPARAM .........................................................................................376 21.9 AT+CADC ......................................................................................................376 21.10 AT+CSCLK ..................................................................................................376 21.11 AT+CMMSDOWN.......................................................................................377 21.12 AT+CFGRI ...................................................................................................377 21.13 Only Part of Projects Support Following AT Commands ............................378 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 14 2015-08-03 Version History Version Date Chapter What is new V1.00 New version All Modify GSM 07.05 to 3GPP TS 27.005,modify GSM 07.07 to 3GPP TS 27.007 1.1 Scope of the document Add SIM800 2.2.8 ATH Delete ATH parameter [n] 2.2.12 +++ Change "0.5 second" to "1 second" 2.2.13 ATO Change "NO CARRIER" to "ERROR" 2.2.26 ATX Change default value from 0 to 4 2.2.32 AT&W Add AT+CFGRI,AT+CSGS 2.2.41.1 Auto-bauding Disable DTR auto-bauding 3.2.14 AT+CHLD Delete parameter of CHLD 3.2.18 AT+CLIP Change URC parameter 3.2.51 AT+CRSL Delete reference Note 3.2.7 AT+CEER Change description of 34 (emergency call not possible) 4.2.10 AT+CRES Delete description of CSCB 4.2.11 AT+CSAS Delete description of CSCB 6.2.4 AT+CMIC Add reference Note 6.2.11 AT+CFGRI Add default value 6.2.16 AT+CCVM Modify Test Command response information and parameter description 6.2.18 AT+CHF Add URC 6.2.26 AT+STTONE Change supported range;delete reference note 6.2.27 AT+SIMTONE Modify last parameter of Test Command to 10-500000 6.2.48 AT+SLEDS Modify default value 6.2.55 AT+CSGS Add ATC 6.2.56 AT+CMICBIAS Add ATC 8.2.2 AT+CIPSTART Modify parameter 8.2.15 AT+CIPHEAD Modify parameter 8.2.20 AT+CIPSRIP Modify parameter 8.2.23 AT+CIPCCFG Modify write cmd parameters V1.01 2013-07-23 8.2.26 AT+CIPRXGET Add "single IP & multi IP connection" information Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 15 2015-08-03 9.2.1 AT+SAPBR Modify parameter 12.2.23 AT+FTPLIST Change "Execution Command" to "Write Command" 14.2.8 AT+SMTPBODY Change "Execution Command" to "Write Command" 14.2.10 AT+SMTPSEND Modify parameter 14.2.11 AT+SMTPFT Change "Execution Command" to "Write Command" 15.2.15 AT+CMMSRECV Change reference note 15.2.21 AT+CMMSTIMEOUT Change "milliseconds" to "seconds" 15.2.25 AT+CMMSSCONT Modify parameter of Execution Command 17.2.1 AT+CREC Add note 18.2.2 AT+CTTSPARAM Modify parameter;add note 20.8 GPRS Commands Modify the CGQREQ example 20.17 RECORD Commands Add example 3.2.17 AT+CLCK Add Max Response Time 3.2.22 AT+COPS Add Max Response Time 3.2.29 AT+CPWD Add Max Response Time 3.2.28 AT+CPIN Add Max Response Time 3.2.41 AT+VTS Add Max Response Time 3.2.44 AT+CPOL Add Max Response Time 3.2.45 AT+COPN Add Max Response Time 3.2.54 AT+CPUC Add Max Response Time 6.2.7 AT+CADC Add Max Response Time 6.2.23 AT+CCID Add Max Response Time 7.2.1 AT+CGATT Add Max Response Time 7.2.5 AT+CGACT Add Max Response Time 3.2.24 AT+CPBF Modify description of max response time 3.2.25 AT+CPBR Modify description of max response time 4.2.1 CMGD Modify description of max response time 4.2.3 CMGL Modify description of max response time 6.2.25 CMGDA Modify description of max response time 15.2.8 AT+CMMSSEND Modify description of max response time 15.2.15 AT+CMMSRECV Modify description of max response time 2.2.16 ATS0 Add parameter saving mode 2.2.20 ATS6 Add parameter saving mode 2.2.21 ATS7 Add parameter saving mode Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 16 2015-08-03 2.2.22 ATS8 Add parameter saving mode 2.2.26 ATX Add parameter saving mode 3.2.4 AT+CBST Add parameter saving mode 3.2.16 AT+CLCC Add parameter saving mode 3.2.12 AT+CSCS Add parameter saving mode 3.2.51 AT+CRSL Add parameter saving mode 3.2.52 AT+CLVL Add parameter saving mode 6.2.33 AT+CIURC Add parameter saving mode 6.2.53 AT_CSDT Add parameter saving mode 6.2.54 AT+CSMINS Add parameter saving mode 3.2.32 AT+CREG Modify parameter save mode 6.2.44 AT+SVR Modify parameter save mode 7.2.10 AT+CGREG Modify parameter save mode 3.2.24 AT+CPBS Delete parameter save mode 3.2.25 AT+CPBW Delete parameter save mode 2.2.28 AT&C Modify the format 3.2.5 AT+CCFC Change error word: to 3.2.33 AT+CRLP Add Save mode and reference 3.2.36 AT+FCLASS Modify information about +FCLASS 3.2.47 AT+CCLK Add note 4.2.5 AT+CMGS Add Note 6.2.18 AT+CHF Modify parameter range and note 6.2.19 AT+CHFA Add patameters of write command and test command,modify note 6.2.20 AT+CSCLK Add new parameter and note 6.2.24 AT+CMTE Increase the temperature range 6.2.28 AT+CCPD Set default value 6.2.33 AT+CIURC Set default value 6.2.41 AT+SPWM Modify parameter direction and note 6.2.51 AT+CNETLIGHT Add test and read command 6.2.53 AT+CSDT Modify note 6.2.55 AT+CSGS Modify parameter default value 6.2.56 AT+CMICBIAS Add default value and modify parameter description 6.2.57 AT+DTAM Add AT command 6.2.58 AT+SJDR Add AT command 6.2.59 AT+CPCMCFG Add AT command V1.02 2013-10-23 6.2.60 AT+CPCMSYNC Add AT command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 17 2015-08-03 6.2.61 AT+CANT Add AT command 6.2.62 AT+CAGCSET Add AT command 7.2.9 AT+CGEREP Modify parameter description and add URC example 8.2.7 AT+CIPSHUT Add Max Response Time 8.2.10 AT+CIICR Add Max Response Time 8.2.21 AT+CIPDPDP Modify parameter’s scope 8.2.26 AT+CIPRXGET Modify parameter options 16.2.1 AT+DDET Add parameter and URC description in write command,add note 17.2.1 AT+CREC Modify note 17.2.2 AT+CRECORD Add AT command 18.2.2 AT+CTTSPARAM Modify note and parameter default value 20.16 AT+DDET Modify AT+DDET example 21.5 AT+CTTSPARAM Add differences of some AT commands 21.6 AT+CHFA Add differences of some AT commands AT+CEXTHS,AT+CEXBUT Delete All Add or modify Parameter Saving Mode and Max Response Time 1.1 Scope of the document Add SIM800G 2.2.28 AT&C Modify parameter format 2.2.32 AT&W Modify parameter stored by &W 2.2.41 AT+IPR Add parameter description 3.2.6 AT+CCWA Modify decription 3.2.24 AT+CPBS Add “FD” phonebook 3.2.46 AT+CALS Add parameter for playing/stopping tone 5.2.1 AT+STKTRS Modify the length of parameter 6.2.1 AT+SIDET Extend parameter 6.2.4 AT+CMIC Extend parameter , add default value description in note 6.2.5 AT+CALA Modify indicate expired alarm 6.2.13 AT+CLDTMF Extend parameter and add parameter , add the funcion that local DTMF tone can be played in call. 6.2.56 AT+CMICBIAS Add note description 6.2.58 AT+SJDR Modify format error 6.2.63 AT+SD2PCM Add AT command V1.03 2014-03-28 6.2.64 AT+SKPD Add AT command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 18 2015-08-03 6.2.65 AT+SIMTONEX Add AT command 6.2.66 AT+CROAMING Add AT command 6.2.67 AT+CNETSCAN Add AT command 8.2.23 AT+CIPCCFG Modify wait time’s interval 12.2.24 AT+FTPGETTOFS Add AT command 16.2.1 AT+DDET Modify description about parameter, add parameter 17.2.1 AT+CREC Modify and AT+CREC=8 description,add read length limit and AMR support description in note 18.2.3 AT+CTTSRING Add command AT+CTTSRING 20.6 Audio command Add AT+CLDTMF example 20.11 PING Commands Add other device ping to the modem 21.6 AT+CHFA Modify description 21.7 AT+CMIC Add difference desription 21.8 AT+SIDET Add difference desription AT+FCLASS AT+FMI AT+FMM AT+FMR Delete 1.1 Scope of the document Add SIM800W16, SIM840W16, SIM800-WB64, SIM808 2.2.27 ATZ Modify note 2.2.30 AT&F Modify note 2.2.32 AT&W Modify note 3.2.46 AT+CALS Modify descripton 4.2.8 AT+CNMI Add the " [alpha>], " string 6.2.1 AT+SIDET Modify note 6.2.4 AT+CMIC Modify note 6.2.8 AT+CSNS Modify parameter save mode 6.2.13 AT+CLDTMF Modify note 6.2.17 AT+CBAND Modify note 6.2.18 AT+CHF Modify note 6.2.19 AT+CHFA Modify note 6.2.40 AT+SGPIO Modify note 6.2.41 AT+SPWM Extend the scope of parameter to "0-100000" 6.2.58 AT+SJDR Modify note V1.04 2014-06-10 6.2.59 AT+CPCMCFG Modify note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 19 2015-08-03 6.2.60 AT+CPCMSYNC Modify note 6.2.62 AT+CANT Modify note 6.2.63 AT+SD2PCM Modify note 6.2.64 AT+SKPD Modify note 6.2.66 AT+CROAMING Modify AT+CROAMING command’s format 6.2.67 AT+CNETSCAN Modify AT+CNETSCAN command’s function and note 6.2.68 AT+CMNRP Add AT command 8.2.2 AT+CIPSTART Modify max response time 8.2.30 AT+CIPTKA Add AT command 10.2.4 AT+CIPBEIPING Add AT command 12.2.2 AT+FTPMODE Modify test and write command 12.2.14 AT+FTPGET Modify note, Add "Manual quit" to 12.2.23 AT+FTPLIST Modify note 12.2.24 AT+FTPGETTOFS Add read command 12.2.25 AT+FTPPUTFRMFS Add AT command 12.2.26 AT+FTPEXTGET Add AT command 12.2.27 AT+FTPFILEPUT Add AT command 12.2.28 AT+FTPQUIT Add AT command 13.2.1 AT+CIPGSMLOC Modify max response time 16.2.1 AT+DDET Modify response value of test command 17.2.1 AT+CREC Modify parameter description and note 18 Modify note 19.3 URC Add URC of AT+CGREG,AT+CALA,AT+CIURC,AT+CNMI 20.2 SIM commands Modify response of AT+CPBS=? 21 Modify ATC difference 21.4 AT+CHFA Add PCM channel in SIM800 and SIM800-WB64 All Change SIM800-WB64 to SIM800M64 6.2.21 AT+CENG Add format description of part parameters 6.2.40 AT+SGPIO Extend the scope of parameter to "1-7" 6.2.69 AT+CEGPRS Add AT command 12.2.24 AT+FTPGETTOFS Modify description of 14.2.14 AT+POP3IN Add description of value 69 14.2.22 AT+POP3OUT Add description of value 69 V1.05 2014-07-31 21.2 AT+CMIC Modify Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 20 2015-08-03 21.5 AT+SGPIO Modify difference 21.9 AT+CADC Add difference 21.10 AT+CSCLK Add difference 21.13 Add GPIO difference 6.2.52 AT+CWHITELIST Extend the scope of parameter to "0-3" 6.2.70 AT+CGPIO Add AT command 6.2.71 AT+CMEDPLAY Add AT command 6.2.72 AT+CMEDIAVOL Add AT command 8.2.14 AT+CDNSGIP Add error code 12.2 Modify max response time 17.2.1 AT+CREC Modify note 1.06 2014-10-28 19.3 Modify note 1.1 Scope of the document Add SIM800C 2.2.16 ATS0 Modify note 6.2.20 AT+CSCLK Modify note 6.2.73 AT+SNDLEVEL Add AT command 1.07 2014-12-19 21 Add differences of SIM800C 6.2.55 AT+CSGS Extend the scope of parameter to "0-2" 6.2.74 AT+ECHARGE Add AT command 6.2.75 AT+SIMTIMER Add AT command 6.2.76 AT+SPE Add AT command 17.2.1 AT+CREC Modify note 19.1 Change CME error codes from 810
824 to 600614 1.08 2015-05-12 21.13 Add AT+ECHARGE,AT+SIMTIMER,AT+SPE 1.1 Scope of the document Add SIM800A, SIM800F, SIM800C-DS 6.2.21 AT+CENG Extend the scope of parameter to "0-4" and modify note 6.2.65 AT+SIMTONEX Modify note 6.2.70 AT+CGPIO Modify response value of test command 6.2.71 AT+CMEDPLAY Modify note 6.2.77 AT+CCONCINDEX Add AT command 6.2.78 AT+SDMODE Add AT command 6.2.79 AT+SRSPT Add AT command 11.2.9 AT+HTTPHEAD Add AT command 15.2.6 AT+CMMSDOWN Modify parameter 17.2.1 AT+CREC Modify note 1.09 2015-08-03 19.3 Delete URC of "AT+CENG" when =3 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 21 2015-08-03 20.2 SIM commands Add examples of "AT+CENG" 21.11 AT+CMMSDOWN Add difference of "AT+CMMSDOWN" 21.12 AT+CFGRI Add difference of "AT+CFGRI" 21 Add differences of SIM800A,SIM800F and SIM800C-DS Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 22 2015-08-03 1 Introduction 1.1 Scope of the document This document presents the AT Command Set for SIMCom SIM800 Series, including SIM800V, SIM840V, SIM800W, SIM840W, SIM800W16, SIM840W16, SIM800L, SIM800H, SIM800, SIM800M64, SIM800G, SIM808, SIM800C, SIM800A, SIM800F and SIM800C-DS. 1.2 Related documents You can visit the SIMCom Website using the following link: http://www.sim.com 1.3 Conventions and abbreviations In this document, the GSM engines are referred to as following term: ME (Mobile Equipment); MS (Mobile Station); TA (Terminal Adapter); DCE (Data Communication Equipment) or facsimile DCE (FAX modem, FAX board); In application, controlling device controls the GSM engine by sending AT Command via its serial interface. The controlling device at the other end of the serial line is referred to as following term: TE (Terminal Equipment); DTE (Data Terminal Equipment) or plainly "the application" which is running on an embedded system; 1.4 AT Command syntax The "AT" or "at" or “aT” or “At”prefix must be set at the beginning of each Command line. To terminate a Command line enter . Commands are usually followed by a response that includes. "" Throughout this document, only the responses are presented, are omitted intentionally. The AT Command set implemented by SIM800 Series is a combination of 3GPP TS 27.005, 3GPP TS 27.007 and ITU-T recommendation V.25ter and the AT commands developed by SIMCom. Note: A HEX string such as "00 49 49 49 49 FF FF FF FF" will be sent out through serial port at the baud rate of 115200 immediately after SIM800 Series is powered on. The string Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 23 2015-08-03 shall be ignored since it is used for synchronization with PC tool. Only enter AT Command through serial port after SIM800 Series is powered on and Unsolicited Result Code "RDY" is received from serial port. If auto-bauding is enabled, the Unsolicited Result Codes "RDY" and so on are not indicated when you start up the ME, and the "AT" prefix, or "at" prefix must be set at the beginning of each command line. All these AT commands can be split into three categories syntactically: "basic", "S parameter", and "extended". These are as follows: 1.4.1 Basic syntax These AT commands have the format of "AT", or "AT&", where ""is the Command, and ""is/are the argument(s) for that Command. An example of this is "ATE", which tells the DCE whether received characters should be echoed back to the DTE according to the value of "". "" is optional and a default will be used if missing. 1.4.2 S Parameter syntax These AT commands have the format of "ATS=", where "" is the index of the S register to set, and ""is the value to assign to it. "" is optional; if it is missing, then a default value is assigned. 1.4.3 Extended Syntax These commands can operate in several modes, as in the following table: Table 1: Types of AT commands and responses Test Command AT+=? The mobile equipment returns the list of parameters and value ranges set with the corresponding Write Command or by internal processes. Read Command AT+? This command returns the currently set value of the parameter or parameters. Write Command AT+=<…> This command sets the user-definable parameter values. Execution Command AT+ The execution command reads non-variable parameters affected by internal processes in the GSM engine. 1.4.4 Combining AT commands on the same Command line You can enter several AT commands on the same line. In this case, you do not need to type the "AT" or "at" prefix before every command. Instead, you only need type "AT" or "at" the Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 24 2015-08-03 beginning of the command line. Please note to use a semicolon as the command delimiter after an extended command; in basic syntax or S parameter syntax, the semicolon need not enter, for example: ATE1Q0S0=1S3=13V1X4;+IFC=0,0;+IPR=115200;&W. The Command line buffer can accept a maximum of 556 characters (counted from the first command without “AT” or “at” prefix). If the characters entered exceeded this number then none of the Command will executed and TA will return "ERROR". 1.4.5 Entering successive AT commands on separate lines When you need to enter a series of AT commands on separate lines, please Note that you need to wait the final response (for example OK, CME error, CMS error) of last AT Command you entered before you enter the next AT Command. 1.5 Supported character sets The SIM800 Series AT Command interface defaults to the IRA character set. The SIM800 Series supports the following character sets: GSM format UCS2 HEX IRA PCCP PCDN 8859-1 The character set can be set and interrogated using the "AT+CSCS" Command (3GPP TS 27.007). The character set is defined in GSM specification 3GPP TS 27.005. The character set affects transmission and reception of SMS and SMS Cell Broadcast messages, the entry and display of phone book entries text field and SIM Application Toolkit alpha strings. 1.6 Flow control Flow control is very important for correct communication between the GSM engine and DTE. For in the case such as a data or fax call, the sending device is transferring data faster than the receiving side is ready to accept. When the receiving buffer reaches its capacity, the receiving device should be capable to cause the sending device to pause until it catches up. There are basically two approaches to achieve data flow control: software flow control and hardware flow control. SIM800 Series support both two kinds of flow control. In Multiplex mode, it is recommended to use the hardware flow control. 1.6.1 Software flow control (XON/XOFF flow control) Software flow control sends different characters to stop (XOFF, decimal 19) and resume (XON, decimal 17) data flow. It is quite useful in some applications that only use three wires on the Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 25 2015-08-03 serial interface. The default flow control approach of SIM800 Series is hardware flow control (RTS/CTS flow control), to enable software flow control in the DTE interface and within GSM engine, type the following AT Command: AT+IFC=1, 1 This setting is stored volatile, for use after restart, AT+IFC=1, 1 should be stored to the user profile with AT&W. NOTE: The AT commands listed in the table of AT&W chapter should be stored to user profile with AT&W for use after restart. Most other AT commands in V.25, 3GPP TS 27.005, 3GPP TS 27.007,GPRS will store parameters automatically and can be used after module restart. Ensure that any communications software package (e.g. Hyper terminal) uses software flow control. NOTE: Software Flow control should not be used for data calls where binary data will be transmitted or received (e.g. TCP/IP) as the DTE interface may interpret binary data as flow control characters. 1.6.2 Hardware flow control (RTS/CTS flow control) Hardware flow control achieves the data flow control by controlling the RTS/CTS line. When the data transfer should be suspended, the CTS line is set inactive until the transfer from the receiving buffer has completed. When the receiving buffer is ok to receive more data, CTS goes active once again. To achieve hardware flow control, ensure that the RTS/CTS lines are present on your application platform. 1.7 Definitions 1.7.1 Parameter Saving Mode For the purposes of the present document, the following syntactical definitions apply: NO_SAVE: The parameter of the current AT command will be lost if module is rebooted or current AT command doesn't have parameter. AUTO_SAVE: The parameter of the current AT command will be kept in NVRAM automatically, and it won't be lost if module is rebooted. AT&W_SAVE: The parameter of the current AT command will be kept in NVRAM by sending the command of “AT&W.” Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 26 2015-08-03 1.7.2 Max Response Time Max response time is estimated maximum time to get response, the unit is seconds. "-" means this AT command doesn’t care the response time. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 27 2015-08-03 2 AT Commands According to V.25TER These AT Commands are designed according to the ITU-T (International Telecommunication Union, Telecommunication sector) V.25ter document. 2.1 Overview of AT Commands According to V.25TER Command Description A/ Re-issues the last command given ATA Answer an incoming call ATD Mobile originated call to dial a number ATD> Originate call to phone number in current memory ATD> Originate call to phone number in memory which corresponds to field ATDL Redial last telephone number used ATE Set command echo mode ATH Disconnect existing connection ATI Display product identification information ATL Set monitor speaker loudness ATM Set monitor speaker mode +++ Switch from data mode or ppp online mode to command mode ATO Switch from command mode to data mode ATP Select pulse dialling ATQ Set result code presentation mode ATS0 Set number of rings before automatically answering the call ATS3 Set command line termination character ATS4 Set response formatting character ATS5 Set command line editing character ATS6 Pause before blind dialling ATS7 Set number of seconds to wait for connection completion ATS8 Set number of seconds to wait for comma dial modifier encountered in dial string of D command ATS10 Set disconnect delay after indicating the absence of data carrier ATT Select tone dialing ATV TA response format ATX Set connect result code format and monitor call progress ATZ Reset default configuration AT&C Set DCD function mode AT&D Set DTR function mode Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 28 2015-08-03 AT&F Factory defined configuration AT&V Display current configuration AT&W Store active profile AT+GCAP Request complete TA capabilities list AT+GMI Request manufacturer identification AT+GMM Request TA model identification AT+GMR Request TA revision identification of software release AT+GOI Request global object identification AT+GSN Request TA serial number identification (IMEI) AT+ICF Set TE-TA control character framing AT+IFC Set TE-TA local data flow control AT+IPR Set TE-TA fixed local rate AT+HVOIC Disconnect voice call only 2.2 Detailed Description of AT Commands According to V.25TER 2.2.1 A/ Re-issues the Last Command Given A/ Re-issues the Last Command Given Execution Command A/ Response Re-issues the previous Command Reference V.25ter Note 2.2.2 ATA Answer an Incoming Call ATA Answer an Incoming Call Execution Command ATA Response TA sends off-hook to the remote station. Note1: Any additional commands on the same Command line are ignored. Note2: This Command may be aborted generally by receiving a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. Response in case of data call, if successfully connected CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to Command mode after call release OK Response in case of voice call, if successfully connected Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 29 2015-08-03 OK Response if no connection NO CARRIER Parameter Saving Mode NO_SAVE Max Response Time 20s(voice call) Timeout set with ATS7 (data call) Reference V.25ter Note See also ATX 2.2.3 ATD Mobile Originated Call to Dial A Number ATD Mobile Originated Call to Dial A Number Execution Command ATD[<mgsm ][;] Response This Command can be used to set up outgoing voice, data or fax calls. It also serves to control supplementary services. Note: This Command may be aborted generally by receiving an ATH Command or a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. If error is related to ME functionality +CME ERROR: If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE If busy and (parameter setting ATX3 or ATX4) BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to Command mode after call release OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 30 2015-08-03 If connection successful and voice call OK Parameters String of dialing digits and optionally V.25ter modifiers dialing digits: 0-9, * , #, +, A, B, C Following V.25ter modifiers are ignored: ,(comma), T, P, !, W, @ Emergency call: Standardized emergency number 112 (no SIM needed) String of GSM modifiers: I Actives CLIR (Disables presentation of own number to called party) i Deactivates CLIR (Enable presentation of own number to called party) G Activates Closed User Group invocation for this call only g Deactivates Closed User Group invocation for this call only <;> Only required to set up voice call , return to Command state Parameter Saving Mode NO_SAVE Max Response Time 20s(voice call) Timeout set with ATS7 (data call) Reference V.25ter Note Parameter "I" and "i" only if no *# code is within the dial string is default for last number that can be dialed by ATDL *# codes sent with ATD are treated as voice calls. Therefore, the Command must be terminated with a semicolon ";" See ATX Command for setting result code and call monitoring parameters. Responses returned after dialing with ATD For voice call two different responses mode can be determined. TA returns "OK" immediately either after dialing was completed or after the call is established. The setting is controlled by AT+COLP. Factory default is AT+COLP=0, this cause the TA returns "OK" immediately after dialing was completed, otherwise TA will returns "OK", "BUSY", "NO DIAL TONE", "NO CARRIER". Using ATD during an active voice call: When a user originates a second voice call while there is already an active voice call, the first call will be automatically put on hold. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 31 2015-08-03 The current states of all calls can be easily checked at any time by using the AT+CLCC Command. 2.2.4 ATD> Originate Call to Phone Number in Current Memory ATD> Originate Call to Phone Number in Current Memory Response This Command can be used to dial a phone number from current phonebook memory. Note: This Command may be aborted generally by receiving an ATH Command or a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. If error is related to ME functionality +CME ERROR: If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE If busy and (parameter setting ATX3 or ATX4) BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to Command mode after call release OK If successfully connected and voice call OK Execution Command ATD>[ ][][;] Parameters Integer type memory location should be in the range of locations available in the memory used String of GSM modifiers: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 32 2015-08-03 I Override the CLIR supplementary service subscription default value for this call Invocation (restrict CLI presentation) i Override the CLIR supplementary service subscription default value for this call Suppression (allow CLI presentation) G Control the CUG supplementary service information for this call CUG Not supported g Control the CUG supplementary service information for this call CUG Not supported <;> Only required to set up voice call , return to Command state Parameter Saving Mode NO_SAVE Max Response Time
Reference V.25ter Note Parameter "I" and "i" only if no *# code is within the dial string *# codes sent with ATD are treated as voice calls. Therefore, the Command must be terminated with a semicolon ";" See ATX Command for setting result code and call monitoring parameters. 2.2.5 ATD> Originate Call to Phone Number in Memory Which Corresponds to Field ATD> Originate Call to Phone Number in Memory Which Corresponds to Field Execution Command ATD>[<clir][][;] Response This Command make the TA attempts to set up an outgoing call to stored number. All available memories are searched for the entry . Note: This Command may be aborted generally by receiving an ATH Command or a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. If error is related to ME functionality +CME ERROR: If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 33 2015-08-03 If busy and (parameter setting ATX3 or ATX4) BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to Command mode after call release OK If successfully connected and voice call OK Parameters String type (string should be included in quotation marks) value ("x"), which should equal to an alphanumeric field in at least one phone book entry in the searched memories. formatted as current TE character set specified by +CSCS. String of GSM modifiers: I Actives CLIR (Disables presentation of own number to called party) i Deactivates CLIR (Enable presentation of own number to called party) G Activates Closed User Group invocation for this call only g Deactivates Closed User Group invocation for this call only <;> Only required to set up voice call, return to Command state Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note Parameter "I" and "i" only if no "*#" code is within the dial string *# codes sent with ATD are treated as voice calls. Therefore, the Command must be terminated with a semicolon ";" See ATX Command for setting result code and call monitoring parameters. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 34 2015-08-03 2.2.6 ATDL Redial Last Telephone Number Used ATDL Redial Last Telephone Number Used Execution Command ATDL Response This Command redials the last voice and data call number used. Note: This Command may be aborted generally by receiving an ATH Command or a character during execution. The aborting is not possible during some states of connection establishment such as handshaking. If error is related to ME functionality +CME ERROR: If no dial tone and (parameter setting ATX2 or ATX4) NO DIALTONE If busy and (parameter setting ATX3 or ATX4) BUSY If a connection cannot be established NO CARRIER If the remote station does not answer NO ANSWER If connection successful and non-voice call. CONNECT TA switches to data mode. Note: output only if ATX parameter setting with the >0 When TA returns to Command mode after call release OK If successfully connected and voice call OK Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note See ATX Command for setting result code and call monitoring parameters. Return the numbers and symbols which ATD supports if there is no last dialing context. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 35 2015-08-03 2.2.7 ATE Set Command Echo Mode ATE Set Command Echo Mode Response This setting determines whether or not the TA echoes characters received from TE during Command state. OK Execution Command ATE Parameters 0 Echo mode off 1 Echo mode on Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note 2.2.8 ATH Disconnect Existing Connection ATH Disconnect Existing Connection Execution Command ATH Response Disconnect existing call by local TE from Command line and terminate call OK Note: OK is issued after circuit 109(DCD) is turned off, if it was previously on. Parameter Saving Mode NO_SAVE Max Response Time 20s Reference V.25ter Note 2.2.9 ATI Display Product Identification Information ATI Display Product Identification Information Execution Command ATI Response TA issues product information text Example: SIM800 R11.08 OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 36 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 2.2.10 ATL Set Monitor speaker loudness ATL Set Monitor speaker loudness Response OK Execution Command ATL Parameters 0..9 Volume Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note No effect in GSM 2.2.11 ATM Set Monitor Speaker Mode ATM Set Monitor Speaker Mode Response OK Execution Command ATM Parameters 0..9 Mode Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note No effect in GSM 2.2.12 +++ Switch from Data Mode or PPP Online Mode to Command Mode +++ Switch from Data Mode or PPP Online Mode to Command Mode Execution Command +++ Response The +++ character sequence causes the TA to cancel the data flow over the AT interface and switch to Command mode. This allows you to enter AT Command while maintaining the data connection to the remote server. OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 37 2015-08-03 To prevent the +++ escape sequence from being misinterpreted as data, it should comply to following sequence: No characters entered for T1 time (1 second) "+++" characters entered with no characters in between (1 second) No characters entered for T1 timer (1 second) Switch to Command mode, otherwise go to step 1. Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note To return from Command mode back to data mode: Enter ATO. 2.2.13 ATO Switch from Command Mode to Data Mode ATO Switch from Command Mode to Data Mode Response TA resumes the connection and switches back from Command mode to data mode. CONNECT If connection is not successfully resumed ERROR else TA returns to data mode from command mode CONNECT Note: only if parameter setting ATX>0 Execution Command ATO[n] Parameter 0 Switch from command mode to data mode. Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 2.2.14 ATP Select Pulse Dialling ATP Select Pulse Dialling Execution Command ATP Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 38 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note No effect in GSM 2.2.15 ATQ Set Result Code Presentation Mode ATQ Set Result Code Presentation Mode Response This parameter setting determines whether or not the TA transmits any result code to the TE. Information text transmitted in response is not affected by this setting. If =0: OK If =1: (none) Execution Command ATQ Parameters 0 TA transmits result code 1 Result codes are suppressed and not transmitted Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note 2.2.16 ATS0 Set Number of Rings before Automatically Answering the Call ATS0 Set Number of Rings before Automatically Answering the Call Response OK Read Command ATS0? Parameters See Write Command Response This parameter setting determines the number of rings before auto-answer. OK ERROR Write Command ATS0= Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 39 2015-08-03 0 Automatic answering is disable. 1-255 Number of rings the modem will wait for before answering the phone if a ring is detected. Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note If is set too high, the calling party may hang up before the call can be answered automatically. If using cmux port, ATH and AT+CHUP can hang up the call (automatically answering) only in the CMUX channel 0. If using dual-physical serial port, ATH and AT+CHUP can hang up the call (automatically answering) only in UART1. 2.2.17 ATS3 Set Command Line Termination Character ATS3 Set Command Line Termination Character Response OK Read Command ATS3? Parameters See Write Command Response This parameter setting determines the character recognized by TA to terminate an incoming Command line. The TA also returns this character in output. OK ERROR Write Command ATS3= Parameters 13 Command line termination character Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note Default 13 = CR. It only supports default value. 2.2.18 ATS4 Set Response Formatting Character ATS4 Set Response Formatting Character Read Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 40 2015-08-03 OK ATS4? Parameters See Write Command Response This parameter setting determines the character generated by the TA for result code and information text. OK ERROR Write Command ATS4= Parameters 10 Response formatting character Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note Default 10 = LF. It only supports default value. 2.2.19 ATS5 Set Command Line Editing Character ATS5 Set Command Line Editing Character Response OK Read Command ATS5? Parameters See Write Command Response This parameter setting determines the character recognized by TA as a request to delete from the Command line the immediately preceding character. OK ERROR Write Command ATS5= Parameters 0-8-127 Response formatting character Parameter Saving Mode AT&W_SAVE Max Response - Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 41 2015-08-03 Time Reference V.25ter Note Default 8 = Backspace. 2.2.20 ATS6 Pause Before Blind Dialling ATS6 Pause Before Blind Dialling Read Command ATS6? Response OK Response OK ERROR Write Command ATS6= Parameters 0..999 Time Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note No effect in GSM 2.2.21 ATS7 Set Number of Seconds to Wait for Connection Completion ATS7 Set Number of Seconds to Wait for Connection Completion Response OK Read Command ATS7? Parameters See Write Command Response This parameter setting determines the amount of time to wait for the connection completion in case of answering or originating a call. OK ERROR Write Command ATS7= Parameters 1-60-255 Number of seconds to wait for connection completion Parameter Saving Mode AT&W_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 42 2015-08-03 Max Response TimeReference V.25ter Note If called party has specified a high value for ATS0=, call setup may fail. The correlation between ATS7 and ATS0 is important Example: Call may fail if ATS7=30 and ATS0=20. ATS7 is only applicable to data call. 2.2.22 ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in Dial String of D Command ATS8 Set Number of Seconds to Wait for Comma Dial Modifier Encountered in Dial String of D Command Response OK Read Command ATS8? Parameters See Write Command Response OK ERROR Write Command ATS8= Parameters 0-255 The value of this register determines how long the modem should pause when it sees a comma in the dialing string. Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note No effect in GSM 2.2.23 ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier ATS10 Set Disconnect Delay after Indicating the Absence of Data Carrier Response OK Read Command ATS10? Parameters See Write Command Write Command ATS10= Response This parameter setting determines the amount of time that the TA will Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 43 2015-08-03 remain connected in absence of data carrier. If the data carrier is once more detected before disconnecting, the TA remains connected. OK ERROR Parameters 1-15-254 Number of tenths seconds of delay Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note 2.2.24 ATT Select Tone Dialing ATT Select Tone Dialing Execution Command ATT Response OK Parameter Saving Mode AUTO_SAVE Max Response TimeReference V.25ter Note 2.2.25 ATV TA Response Format ATV TA Response Format Response This parameter setting determines the contents of the header and trailer transmitted with result codes and information responses. When =0 0 When =1 OK Execution Command ATV Parameters 0 Information response: Short result code format: 1 Information response: Long result code format: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 44 2015-08-03 The result codes, their numeric equivalents and brief descriptions of the use of each are listed in the following table. Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note ATV1 ATV0 Description OK 0 Acknowledges execution of a Command CONNECT 1 A connection has been established; the DCE is moving from Command state to online data state RING 2 The DCE has detected an incoming call signal from network NO CARRIER 3 The connection has been terminated or the attempt to establish a connection failed ERROR 4 Command not recognized, Command line maximum length exceeded, parameter value invalid, or other problem with processing the Command line NO DIALTONE 6 No dial tone detected BUSY 7 Engaged (busy) signal detected NO ANSWER 8 "@" (Wait for Quiet Answer) dial modifier was used, but remote ringing followed by five seconds of silence was not detected before expiration of the connection timer (S7) PROCEEDING 9 An AT command is being processed CONNECT Manufacturerspecific Same as CONNECT, but includes manufacturer-specific text that may specify DTE speed, line speed, error control, data compression, or other status 2.2.26 ATX Set CONNECT Result Code Format and Monitor Call Progress ATX Set CONNECT Result Code Format and Monitor Call Progress Response This parameter setting determines whether or not the TA detected the presence of dial tone and busy signal and whether or not TA transmits particular result codes. OK ERROR Execution Command ATX Parameters 0 CONNECT result code only returned, dial tone and busy Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 45 2015-08-03 detection are both disabled. 1 CONNECT result code only returned, dial tone and busy detection are both disabled. 2 CONNECT result code returned, dial tone detection is enabled, busy detection is disabled. 3 CONNECT result code returned, dial tone detection is disabled, busy detection is enabled. 4 CONNECT result code returned, dial tone and busy detection are both enabled. Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note 2.2.27 ATZ Reset Default Configuration ATZ Reset Default Configuration Response TA sets all current parameters to the user defined profile. OK ERROR Execution Command ATZ[] Parameters 0 Restore profile 0 Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note Parameter impacted by Z command: refer to AT&W NOTE: Parameters related to uart operation, like csclk, ipr, icf, ifc and cmnrp, will not be reset to default configuration. 2.2.28 AT&C Set DCD Function Mode AT&C Set DCD Function Mode Execution Command AT&C Response This parameter determines how the state of circuit 109 (DCD) relates to the detection of received line signal from the distant end. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 46 2015-08-03 OK ERROR Parameters 0 DCD line is always ON 1 DCD line is ON only in the presence of data carrier Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note 2.2.29 AT&D Set DTR Function Mode AT&D Set DTR Function Mode Response This parameter determines how the TA responds when circuit 108/2 (DTR) is changed from the ON to the OFF condition during data mode. OK ERROR Execution Command AT&D[] Parameters 0 TA ignores status on DTR. 1 ON->OFF on DTR: Change to Command mode with remaining the connected call. 2 ON->OFF on DTR: Disconnect call, change to Command mode. During state DTR = OFF is auto-answer off. Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note 2.2.30 AT&F Factory Defined Configuration AT&F Factory Defined Configuration Response TA sets all current parameters to the manufacturer defined profile. OK Execution Command AT&F[] Parameters 0 Set all TA parameters to manufacturer defaults. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 47 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note Parameter impacted by &F command: refer to AT&W NOTE: Parameters related to uart operation, like csclk, ipr, icf, ifc and cmnrp, will not be reset to default configuration. 2.2.31 AT&V Display Current Configuration AT&V Display Current Configuration Response TA returns the current parameter setting. OK ERROR Execution Command AT&V[] Parameters 0 Responses in numeric format Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 2.2.32 AT&W Store Active Profile AT&W Store Active Profile Response TA stores the current parameter setting in the user defined profile. OK ERROR Execution Command AT&W[] Parameters 0 Store the current configuration in profile 0 Parameter Saving Mode NO_SAVE Max Response TimeSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 48 2015-08-03 Reference V.25ter Note The user defined profile is stored in non volatile memory. Parameter stored by &W Command Parameter name Displayedby &V ATS0 Y ATS3 Y ATS4 Y ATS5 Y ATS6 Y ATS7 Y ATS8 Y ATS10 Y AT+CBST ,, Y AT+CRLP ,,, Y ATV Y ATE Y ATQ Y ATX Y AT&C Y AT&D Y AT+CLTS Y AT+CREG Y AT+CGREG Y AT+CMEE Y AT+CSCLK Y AT+CIURC Y AT+CFGRI Y AT+CMTE Y AT+CANT ,, Y AT+STKPCIS Y AT+CMGF Y AT+CNMI ,,,, Y AT+CSCS Y AT+VTD Y AT+CALS Y AT+CHF Y AT+CAAS Y AT+CBUZZERRING Y Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 49 2015-08-03 AT+DDET Y AT+MORING Y AT+SVR <voice_rate_coding> Y AT+CCPD Y AT+CSGS Y AT+CNETLIGHT Y AT+SLEDS ,<timer_on>,<timer_off> Y AT+CSDT Y AT+CSMINS Y AT+EXUNSOL Y AT+IPR Y AT+IFC <TA_by_TE>, <TE_by_TA> Y AT+ICF , Y AT+SD2PCM Y AT+CMNRP Y AT+ECHARGE Y AT+SIMTIMER Y AT+CSNS Y AT+FSHEX Y 2.2.33 AT+GCAP Request Complete TA Capabilities List AT+GCAP Request Complete TA Capabilities List Response TA reports a list of additional capabilities. +GCAP: list of supported s OK Execution Command AT+GCAP Parameters +CGSM GSM function is supported Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note2.2.34 AT+GMI Request Manufacturer Identification AT+GMI Request Manufacturer Identification Test Command AT+GMI=? Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 50 2015-08-03 Parameters Execution Command AT+GMI TA reports one or more lines of information text which permit the user to identify the manufacturer. SIMCOM_Ltd OK Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 2.2.35 AT+GMM Request TA Model Identification AT+GMM Request TA Model Identification Test Command AT+GMM=? Response OK TA reports one or more lines of information text which permit the user to identify the specific model of device. OK Execution Command AT+GMM Parameters Product model identification text Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 2.2.36 AT+GMR Request TA Revision Identification of Software Release AT+GMR Request TA Revision Identification of Software Release Test Command AT+GMR=? Response OK Execution Command TA reports one or more lines of information text which permit the user to identify the revision of software release. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 51 2015-08-03 Revision: OK AT+GMR Parameters Revision of software release Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 2.2.37 AT+GOI Request Global Object Identification AT+GOI Request Global Object Identification Test Command AT+GOI=? Response OK Response TA reports one or more lines of information text which permit the user to identify the device, based on the ISO system for registering unique object identifiers. OK Execution Command AT+GOI Parameters Identifier of device type see X.208, 209 for the format of Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 2.2.38 AT+GSN Request TA Serial Number Identification (IMEI) AT+GSN Request TA Serial Number Identification(IMEI) Test Command AT+GSN=? Response OK Execution Command Response TA reports the IMEI (international mobile equipment identifier) number in Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 52 2015-08-03 information text which permit the user to identify the individual ME device. OK AT+GSN Parameters IMEI of the telephone(International Mobile station Equipment Identity) Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note The serial number (IMEI) is varied by individual ME device. 2.2.39 AT+ICF Set TE-TA Control Character Framing AT+ICF Set TE-TA Control Character Framing Response +ICF: (list of supported s),(list of supported s) OK Test Command AT+ICF=? Parameters See Write Command Response +ICF: , OK Read Command AT+ICF? Parameters See Write Command Response This parameter setting determines the serial interface character framing format and parity received by TA from TE. OK Write Command AT+ICF=[,] Parameters 1 8 data 0 parity 2 stop 2 8 data 1 parity 1 stop 3 8 data 0 parity 1 stop 4 7 data 0 parity 2 stop 5 7 data 1 parity 1 stop 6 7 data 0 parity 1 stop 0 odd 1 even Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 53 2015-08-03 3 space (0) Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note The Command is applied for Command state; In parameter, "0 parity" means no parity; The field is ignored if the field specifies no parity and string "+ICF: ,255" will be response to AT+ICF? Command. 2.2.40 AT+IFC Set TE-TA Local Data Flow Control AT+IFC Set TE-TA Local Data Flow Control Response +IFC: (list of supported <dce_by_dte>s),(list of supported <dte_by_dce>s) OK Test Command AT+IFC=? Parameters See Write Command Response +IFC: <dce_by_dte>,<dte_by_dce> OK Read Command AT+IFC? Parameters See Write Command Response This parameter setting determines the data flow control on the serial interface for data mode. OK Write Command AT+IFC=<dce_b y_dte>[,<dte_by _dce>] Parameters <dce_by_dte> Specifies the method will be used by TE at receive of data from TA 0 No flow control 1 Software flow control 2 Hardware flow control <dte_by_dce> Specifies the method will be used by TA at receive of data from TE 0 No flow control 1 Software flow control 2 Hardware flow control Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 54 2015-08-03 Parameter Saving Mode AT&W_SAVE Max Response TimeReference V.25ter Note 2.2.41 AT+IPR Set TE-TA Fixed Local Rate AT+IPR Set TE-TA Fixed Local Rate Response +IPR: (list of supported auto detectable s),(list of supported fixed-only s) OK Test Command AT+IPR=? Parameters See Write Command Response +IPR: OK Read Command AT+IPR? Parameters See Write Command Response This parameter setting determines the data rate of the TA on the serial interface. The rate of Command takes effect following the issuance of any result code associated with the current Command line. OK Write Command AT+IPR= Parameters Baud rate per second 0 (Auto-bauding) 1200 2400 4800 9600 19200 38400 57600 115200 230400 460800 Parameter Saving Mode AT&W_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 55 2015-08-03 Max Response TimeReference V.25ter Note Factory setting is AT+IPR=0(auto-bauding). 2.2.41.1 Auto-bauding Synchronization between DTE and DCE ensure that DTE and DCE are correctly synchronized and the baud rate used by the DTE is detected by the DCE (= ME).To allow the baud rate to be synchronized, simply issue an "AT" string. This is necessary when you start up the module while auto-bauding is enabled. It is recommended to wait 3 to 5 seconds before sending the first AT character. Otherwise undefined characters might be returned. If you want to use auto-bauding and auto-answer at the same time, you can easily enable the DTE-DCE synchronization, when you activate auto-bauding first and then configure the auto-answer mode. Restrictions on auto-bauding operation The serial interface has to be operated at 8 data bits, no parity and 1 stop bit (factory setting). Only the strings "AT" or "at" can be detected when auto-bauding is enabled. AT+IPR=0 setting to auto-bauding will take effect after module resets. Unsolicited Result Codes that may be issued before the ME detects the new baud rate (by receiving the first AT Command string) will be sent at the previously detected baud rate.The Unsolicited Result Codes "RDY" and so on are not indicated when you start up the ME while auto-bauding is enabled. It is not recommended to switch to auto-bauding from a baud rate that cannot be detected by the auto-bauding mechanism (e.g. 300 baud). Responses to +IPR=0 and any commands on the same line might be corrupted. Auto-bauding and baud rate after restart The most recently detected baud rate can not be stored when module is powered down. 2.2.42 AT+HVOIC Disconnect Voice Call Only AT+HVOIC Disconnect Voice Call Only Execution Command AT+HVOIC Response Disconnect existing voice call by local TE from Command line and terminate call with existing PPP or CSD connection on. OK Parameter Saving Mode NO_SAVE Max Response Time 20s Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 56 2015-08-03 Reference V.25ter Note 3 AT Commands According to 3GPP TS 27.007 3.1 Overview of AT Command According to 3GPP TS 27.007 Command Description AT+CACM Accumulated call meter(ACM) reset or query AT+CAMM Accumulated call meter maximum(ACM max) set or query AT+CAOC Advice of charge AT+CBST Select bearer service type AT+CCFC Call forwarding number and conditions control AT+CCWA Call waiting control AT+CEER Extended error report AT+CGMI Request manufacturer identification AT+CGMM Request model identification AT+CGMR Request TA revision identification of software release AT+CGSN Request product serial number identification (identical with +GSN) AT+CSCS Select TE character set AT+CSTA Select type of address AT+CHLD Call hold and multiparty AT+CIMI Request international mobile subscriber identity AT+CLCC List current calls of ME AT+CLCK Facility lock AT+CLIP Calling line identification presentation AT+CLIR Calling line identification restriction AT+CMEE Report mobile equipment error AT+COLP Connected line identification presentation AT+COPS Operator selection AT+CPAS Phone activity status AT+CPBF Find phonebook entries AT+CPBR Read current phonebook entries AT+CPBS Select phonebook memory storage AT+CPBW Write phonebook entry AT+CPIN Enter PIN AT+CPWD Change password AT+CR Service reporting control AT+CRC Set cellular result codes for incoming call indication Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 57 2015-08-03 AT+CREG Network registration AT+CRLP Select radio link protocol parameters AT+CRSM Restricted SIM access AT+CSQ Signal quality report AT+VTD Tone duration AT+VTS DTMF and tone generation AT+CMUX Multiplexer control AT+CNUM Subscriber number AT+CPOL Preferred operator list AT+COPN Read operator names AT+CFUN Set phone functionality AT+CCLK Clock AT+CSIM Generic SIM access AT+CALM Alert sound mode AT+CALS Alert sound select AT+CRSL Ringer sound level AT+CLVL Loud speaker volume level AT+CMUT Mute control AT+CPUC Price per unit and currency table AT+CCWE Call meter maximum event AT+CBC Battery charge AT+CUSD Unstructured supplementary service data AT+CSSN Supplementary services notification 3.2 Detailed Descriptions of AT Command According to 3GPP TS 27.007 3.2.1 AT+CACM Accumulated Call Meter (ACM) Reset or Query AT+CACM Accumulated Call Meter(ACM) Reset or Query Test Command AT+CACM=? Response OK Response TA returns the current value of ACM. +CACM: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CACM? Parameters String type (string should be included in quotation marks); Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 58 2015-08-03 three bytes of the current ACM value in hexa-decimal format (e.g. "00001E" indicates decimal value 30) 000000 – FFFFFF Response TA resets the Advice of Charge related accumulated call meter (ACM) value in SIM file EF (ACM). ACM contains the total number of home units for both the current and preceding calls. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CACM= Parameters String type (string should be included in quotation marks): SIM PIN2 Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.2 AT+CAMM Accumulated Call Meter Maximum (ACM max) Set or Query AT+CAMM Accumulated Call Meter Maximum(ACM max) Set or Query Test Command AT+CAMM=? Response OK Response TA returns the current value of ACM max. +CAMM: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CAMM? Parameters See Write Command Write Command AT+CAMM=[,<passwd] Response TA sets the Advice of Charge related accumulated call meter maximum value in SIM file EF (ACM max). ACM max contains the maximum number of home units allowed to be consumed by the subscriber. OK ERROR If error is related to ME functionality: +CME ERROR: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 59 2015-08-03 Parameters String type (string should be included in quotation marks); three bytes of the max. ACM value in hex-decimal format (e.g. "00001E" indicates decimal value 30) 000000 disable ACMmax feature 000001-FFFFFF String type (string should be included in quotation marks) SIM PIN2 Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.3 AT+CAOC Advice of Charge AT+CAOC Advice of Charge Response +CAOC: (list of supported s)OK Test Command AT+CAOC=? Parameters See Write Command Response +CAOC: OK Read Command AT+CAOC? Parameters See Write Command Write Command AT+CAOC= Response TA sets the Advice of Charge supplementary service function mode. If =0, TA returns the current call meter value +CAOC: OK If =1, TA deactivates the unsolicited reporting of CCM value OK If =2, TA activates the unsolicited reporting of CCM value OK ERROR If error is related to ME functionality: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 60 2015-08-03 +CME ERROR: Parameters 0 Query CCM value 1 Deactivate the unsolicited reporting of CCM value 2 Activate the unsolicited reporting of CCM value String type (string should be included in quotation marks); three bytes of the current CCM value in hex-decimal format (e.g. "00001E" indicates decimal value 30); bytes are similarly coded as ACMmax value in the SIM 000000-FFFFFF Execution Command AT+CAOC Response +CAOC: OK Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.4 AT+CBST Select Bearer Service Type AT+CBST Select Bearer Service Type Response +CBST: (list of supported s),(list of supported s),(list of supported s) OK Test Command AT+CBST=? Parameters See Write Command Response +CBST: ,, OK Read Command AT+CBST? Parameters See Write Command Response TA selects the bearer service with data rate , and the connection element to be used when data calls are originated. OK ERROR Write Command AT+CBST=[,[,<ce]] Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 61 2015-08-03 0 Auto-bauding (automatic selection of the speed; this setting is possible in case of 3.1kHz modern and non-transparent service) 4 2400 bps (V.22bis) 5 2400 bps (V.26ter) 6 4800 bps (V.32) 7 9600 bps (V.32) 12 9600 bps (V.34) 14 14400 bps (V.34) 68 2400 bps (V.110 or X.31 flag stuffing) 70 4800 bps (V.110 or X.31 flag stuffing) 71 9600 bps (V.110 or X.31 flag stuffing) 75 14400 bps (V.110 or X.31 flag stuffing) 0 Data circuit asynchronous (UDI or 3.1 kHz modem) 4 Data circuit asynchronous (RDI) 0 Transparent 1 Non-transparent 2 Both, transparent prefered 3 Both, non-transparent prefered Parameter Saving Mode AT&W_SAVE Max Response TimeReference 3GPP TS 27.007 [14] Note GSM 02.02[1]: lists the allowed combinations of the sub parameters. 3.2.5 AT+CCFC Call Forwarding Number and Conditions Control AT+CCFC Call Forwarding Number and Conditions Control Response +CCFC: (list of supported s) OK Test Command AT+CCFC=? Parameters See Write Command Write Command AT+CCFC=,[,< number>[,<type[,[,[,[ ,time]]]]]] Response TA controls the call forwarding supplementary service. Registration, erasure, activation, deactivation, and status query are supported. Only , and should be entered with mode (0-2,4) If ≠2 and Command successful OK If =2 and Command successful (only in connection with 0 –3) For registered call forwarding numbers: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 62 2015-08-03 when =2 and command successful: +CCFC: ,[,,[,,[,]]] [+CCFC: ,[,,[,,[,]]][ …] OK If no call forwarding numbers are registered (and therefore all classes are inactive): +CCFC: , OK where =0 and =7 If error is related to ME functionality: +CME ERROR: Parameters 0 Unconditional 1 Mobile busy 2 No reply 3 Not reachable 4 All call forwarding 5 All conditional call forwarding 0 Disable 1 Enable 2 Query status 3 Registration 4 Erasure String type (Phone number of forwarding address in format specified by ) Type of address String type (subaddress of format specified by ) Type of sub-address in integer 1 Voice (telephony) 2 Data (refers to all bearer services; with =2 this may refer only to some bearer service if TA does not support values 16, 32, 64 and 128) 4 Fax (facsimile services) 7 All classes 1..30 When "no reply" is enabled or queried, this gives the time in seconds to wait before call is forwarded, default value is 20.Supported only if it is multiples of 5.0 Not active Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 63 2015-08-03 1 Active Parameter Saving Mode NO_SAVE Max Response Time 15s Reference 3GPP TS 27.007 Note 3.2.6 AT+CCWA Call Waiting Control AT+CCWA Call Waiting Control Response +CCWA: (list of supported s) OK Test Command AT+CCWA=? Parameters See Write Command Response +CCWA: OK Read Command AT+CCWA? Parameters See Write Command Response TA controls the Call Waiting supplementary service. Activation, deactivation and status query are supported. If ≠2 and Command successful OK If =2 and Command successful +CCWA: ,[+CCWA:,[...]]OK ERROR If error is related to ME functionality: +CME ERROR: Note: =0 should be returned only if service is not active for any i.e. +CCWA: 0, 7 will be returned in this case. When mode=2, all active call waiting classes will be reported. In this mode the Command is aborted by pressing any key. Write Command AT+CCWA=[, [,]] Parameters 0 Disable presentation of an unsolicited result code Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 64 2015-08-03 1 Enable presentation of an unsolicited result code When parameter not given, network is not interrogated 0 Disable 1 Enable 2 Query status Is a sum of integers each representing a class of information 1 Voice (telephony) 2 Data (refers to all bearer services; with =2 this may refer only to some bearer service if TA does not support values 16, 32, 64 and 128 4 Fax (facsimile services) 7 Default(1+2+4) 0 Not active 1 Active Unsolicited result code RING +CCWA: ,,[,] Parameters String type (string should be included in quotation marks) phone number of calling address in format specified by Type of address octet in integer format; 129 Unknown type 161 National number type 145 International number type 177 Network specific number Optional string type (string should be included in quotation marks) alphanumeric representation of corresponding to the entry found in phone book. Parameter Saving Mode NO_SAVE Max Response Time 15s Reference 3GPP TS 27.007 Note 3.2.7AT+CEER Extended Error Report AT+CEER Extended Error Report Test Command AT+CEER=? Response +CEER: (list of supported s) OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 65 2015-08-03 Parameters See Write Command Response +CEER: OK Read Command AT+CEER? Parameters See Write Command Response OK Write Command AT+CEER= Parameter 0 The reason for last call release as text code 1 The reason for last call release as number code Response TA returns an extended report of the reason for the last call release. +CEER: OK Parameters If AT+CEER=0, return
a string that represents the Cause If AT+CEER=1, return Cause: number representing the Cause Execution Command AT+CEER Parameters (number) (string) 0 (No cause) 1 (unassigned (unallocated) number) 3 (no route to destination) 6 (channel unacceptable) 8 (operator determined barring) 16 (normal call clearing) 17 (user busy) 18 (no user responding) 19 (user alerting, no answer) 21 (call rejected) 22 (number changed) 26 (non-selected user clearing) 27 (destination out of order) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 66 2015-08-03 28 (invalid number format (incomplete number)) 29 (facility rejected) 30 (response to STATUS ENQUIRY) 31 (normal, unspecified) 34 (emergency call not possible) 38 (network out of order) 41 (temporary failure) 42 (switching equipment congestion) 43 (access information discarded) 44 (requested circuit/channel not available) 47 (resource unavailable, unspecified) 49 (quality of service unavailable) 50 (Requested facility not subscribed) 55 (Incoming calls barred within the CUG) 57 (bearer capability not authorized) 58 (bearer capability not presently available) 63 (service or option not available, unspecified)68 (ACM equal to or greater than ACMmax) 65 (bearer service not implemented) 69 (Requested facility not implemented) 70 (only restricted digital information bearer capability is available) 79 (service or option not implemented,unspecified) 81 (invalid transaction identifier value) 87 (user not member of CUG) 88 (incompatible destination) 91 (invalid transit network selection) 95 (semantically incorrect message) 96 (invalid mandatory information) 97 (message type non-existent or not implemented) 98 (message type not compatible with protocol state) 99 (information element non-existent or not implemented) 100 (conditional IE error) 101 (message not compatible with protocol state) 102 (recovery on timer expiry) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 67 2015-08-03 111 (protocol error, unspecified) 127 (interworking, unspecified) Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.8 AT+CGMI Request Manufacturer Identification AT+CGMI Request Manufacturer Identification Test Command AT+CGMI=? Response OK Response TA returns manufacturer identification text. OK Execution Command AT+CGMI Parameters The ID of manufacturer Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.9 AT+CGMM Request Model Identification AT+CGMM Request Model Identification Test Command AT+CGMM=? Response OK Response TA returns product model identification text. OK Execution Command AT+CGMM Parameters Product model identification text Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 68 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.10 AT+CGMR Request TA Revision Identification of Software Release AT+CGMR Request TA Revision Identification of Software Release Test Command AT+CGMR=? Response OK Response TA returns product software version identification text. Revision: OK Execution Command AT+CGMR Parameters Product software version identification text Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.11 AT+CGSN Request Product Serial Number Identification (Identical with +GSN) AT+CGSN Request Product Serial Number Identification (Identical with +GSN) Test Command AT+CGSN=? Response OK Response see +GSN OK Execution Command AT+CGSN Parameters International mobile equipment identity (IMEI) Parameter Saving Mode NO_SAVE Max Response - Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 69 2015-08-03 Time Reference 3GPP TS 27.007 [13] Note 3.2.12 AT+CSCS Select TE Character Set AT+CSCS Select TE Character Set Response +CSCS: (list of supported s) OK Test Command AT+CSCS=? Parameters "GSM" GSM 7 bit default alphabet (3GPP TS 23.038); "UCS2" 16-bit universal multiple-octet coded character set (ISO/IEC10646); UCS2 character strings are converted to hexadecimal numbers from 0000 to FFFF; e.g. "004100620063" equals three 16-bit characters with decimal values 65, 98 and 99 "IRA" International reference alphabet (ITU-T T.50) "HEX" Character strings consist only of hexadecimal bers from 00 to FF; "PCCP" PC character set Code "PCDN" PC Danish/Norwegian character set "8859-1" ISO 8859 Latin 1 character set Response +CSCS: OK Read Command AT+CSCS? Parameters See Test Command Response Sets which character set are used by the TE. The TA can then convert character strings correctly between the TE and ME character sets. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CSCS= Parameters See Test Command Parameter Saving Mode AT&W_SAVE Max Response TimeSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 70 2015-08-03 Reference 3GPP TS 27.007 [13] Note 3.2.13 AT+CSTA Select Type of Address AT+CSTA Select Type of Address Response +CSTA: (list of supported s) OK Test Command AT+CSTA=? Parameters See Write Command Response +CSTA: OK Read Command AT+CSTA? Parameter Current address type setting. Response OK If is not in the parameter range: ERROR Write Command AT+CSTA=<typeParameters Type of address octet in integer format; 129 Unknown type 161 National number type 145 International number type 177 Network specific number Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note The ATD Command overrides this setting when a number is dialed. 3.2.14 AT+CHLD Call Hold and Multiparty AT+CHLD Call Hold and Multiparty Test Command AT+CHLD=? Response +CHLD: (list of supported s) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 71 2015-08-03 OK Parameters See Write Command Response TA controls the supplementary services Call Hold, Multiparty and Explicit Call Transfer. Calls can be put on hold, recovered, released, added to conversation, and transferred. Note These supplementary services are only applicable to tele service 11 (Speech: Telephony). OK If error is related to ME functionality: +CME ERROR: Write Command AT+CHLD= Parameters 0 Releases all held calls or sets User Determined User Busy (UDUB) for a waiting call 1 Releases all active calls (if any exist) and accepts the other (held or waiting) call. 1x Releases a specific call x 2 Place all active calls on hold (if any) and accept the other (held or waiting) call. 2x Places all active calls on hold except call X with which communication shall be supported. 3 Adds a held call to the conversation. 4 Connects the two calls and disconnects the subscriber from both calls(ECT) Parameter Saving Mode NO_SAVE Max Response Time 20s Reference Note 3.2.15 AT+CIMI Request International Mobile Subscriber Identity AT+CIMI Request International Mobile Subscriber Identity Test Command AT+CIMI=? Response OK Execution Command AT+CIMI Response TA returns for identifying the individual SIM which is attached to ME. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 72 2015-08-03 OK If error is related to ME functionality: +CME ERROR: Parameters International Mobile Subscriber Identity (string without double quotes) Parameter Saving Mode NO_SAVE Max Response Time 20s Reference 3GPP TS 27.007 [13] Note 3.2.16 AT+CLCC List Current Calls of ME AT+CLCC List Current Calls of ME Response +CLCC: (0,1) OK Test Command AT+CLCC=? Parameters See Write Command Response +CLCC: OK Read Command AT+CLCC? Parameters See Write Command Response OK Write Command AT+CLCC= Parameters 0 Don’t report a list of current calls of ME automatically when the current call status changes. 1 Report a list of current calls of ME automatically when the current call status changes. Execution Command AT+CLCC Response TA returns a list of current calls of ME. Note: If Command succeeds but no calls are available, no information response is sent to TE. [+CLCC: ,,,,[,,<type,] [+CLCC: ,,,, Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 73 2015-08-03 [,,,][...]]] OK If error is related to ME functionality: +CME ERROR: Parameters 1..7 Call identification number This number can be used in +CHLD command operations0 Mobile originated (MO) call 1 Mobile terminated (MT) call State of the call: 0 Active 1 Held 2 Dialing (MO call) 3 Alerting (MO call) 4 Incoming (MT call) 5 Waiting (MT call) 6 Disconnect Bearer/tele service: 0 Voice 1 Data 2 Fax 0 Call is not one of multiparty (conference) call parties 1 Call is one of multiparty (conference) call parties String type (string should be included in quotation marks) phone number in format specified by . Type of address String type (string should be included in quotation marks) alphanumeric representation of corresponding to the entry found in phone book. Parameter Saving Mode AUTO_SAVE Max Response Time - Reference 3GPP TS 27.007 [13][14] Note 3.2.17 AT+CLCK Facility Lock AT+CLCK Facility Lock Test Command AT+CLCK=? Response +CLCK: (list of supported s) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 74 2015-08-03 OK Parameters See Write Command Response This Command is used to lock, unlock or interrogate a ME or a network facility . Password is normally needed to do such actions. When querying the status of a network service (=2) the response line for ‘not active’ case (=0) should be returned only if service is not active for any . If ≠2 and Command is successful OK If =2 and Command is successful +CLCK: [,[+CLCK: ,[…]] OK If error is related to ME functionality: +CME ERROR: Write Command AT+CLCK= ,[,[,]] Parameters "AO" BAOC (Barr All Outgoing Calls) "OI" BOIC (Barr Outgoing International Calls) "OX" BOIC-exHC (Barr Outgoing International Calls except to Home Country) "AI" BAIC (Barr All Incoming Calls) "IR" BIC-Roam (Barr Incoming Calls when Roaming outside the home country) "FD" SIM card or active application in the UICC (GSM or USIM) fixed dialling memory feature (if PIN2 authentication has not been done during the current session, PIN2 is required as ) "SC" SIM (lock SIM/UICC card) (SIM/UICC asks password in MT power-up and when this lock command issued) Correspond to PIN1 code. "PN" Network Personalization, Correspond to NCK code "PU" Network subset Personalization Correspond to NSCK code "PP" Service Provider Personalization Correspond to SPCK code 0 unlock 1 lock 2 query status String type (Shall be the same as password specified for the Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 75 2015-08-03 facility from the MT user interface or with command Change Password +CPWD) 1 Voice (telephony) 2 Data refers to all bearer services; with =2 this may refer only to some bearer service if TA does not support values 16, 32, 64 and 128) 4 Fax (facsimile services) 7 All classes 0 Not active 1 Active Parameter Saving Mode NO_SAVE Max Response Time 15s Reference 3GPP TS 27.007 [14] Note CME errors if SIM not inserted or PIN is not entered. 3.2.18 AT+CLIP Calling Line Identification Presentation AT+CLIP Calling Line Identification Presentation Response +CLIP: (list of supported s) OK Test Command AT+CLIP=? Parameters See Write Command Response +CLIP: , OK If error is related to ME functionality: +CME ERROR: Read Command AT+CLIP? Parameters See Write Command Response TA enables or disables the presentation of the CLI at the TE. It has no effect on the execution of the supplementary service CLIP in the network. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CLIP= Parameters 0 Disable +CLIP notification. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 76 2015-08-03 1 Enable +CLIP notification. 0 CLIP not provisioned 1 CLIP provisioned 2 Unknown (e.g. no network, etc.) Unsolicited Result Code When the presentation of the CLI at the TE is enabled (and calling subscriber allows), an unsolicited result code is returned after every RING (or +CRING: ) at a mobile terminating call. +CLIP: ,[,,,,] Parameters String type (string should be included in quotation marks) phone number of calling address in format specified by . Type of address octet in integer format; 129 Unknown type 161 National number type 145 International number type 177 Network specific number String type (subaddress of format specified by ) Integer type (type of subaddress) String type (string should be included in quotation marks) alphanumeric representation of corresponding to the entry found in phone book. 0 CLI valid 1 CLI has been withheld by the originator. 2 CLI is not available due to interworking problems or limitations of originating network. Parameter Saving Mode NO_SAVE Max Response Time 15s Reference Note 3.2.19 AT+CLIR Calling Line Identification Restriction AT+CLIR Calling Line Identification Restriction Response +CLIR: (list of supported s) OK Test Command AT+CLIR=? Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 77 2015-08-03 See Write Command Response +CLIR: , OK If error is related to ME functionality: +CME ERROR: Read Command AT+CLIR? Parameters See Write Command Response TA restricts or enables the presentation of the CLI to the called party when originating a call. The Command overrides the CLIR subscription (default is restricted or allowed) when temporary mode is provisioned as a default adjustment for all following outgoing calls. This adjustment can be revoked by using the opposite Command. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CLIR= Parameters (parameter sets the adjustment for outgoing calls): 0 Presentation indicator is used according to the subscription of the CLIR service. 1 CLIR invocation 2 CLIR suppression (parameter shows the subscriber CLIR service status in the network): 0 CLIR not provisioned 1 CLIR provisioned in permanent mode 2 Unknown (e.g. no network, etc.) 3 CLIR temporary mode presentation restricted 4 CLIR temporary mode presentation allowedParameter Saving Mode NO_SAVE Max Response Time 15s Reference Note 3.2.20 AT+CMEE Report Mobile Equipment Error AT+CMEE Report Mobile Equipment Error Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 78 2015-08-03 Response +CMEE: (list of supported s) OK Test Command AT+CMEE=? Parameters See Write Command Response +CMEE: OK Read Command AT+CMEE? Parameters See Write Command Response TA disables or enables the use of result code +CME ERROR: as an indication of an error relating to the functionality of the ME. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CMEE=[ ] Parameters 0 Disable +CME ERROR: result code and use ERROR instead. 1 Enable +CME ERROR: result code and use numeric 2 Enable +CME ERROR: result code and use verbose values Parameter Saving Mode AT&W_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.21 AT+COLP Connected Line Identification Presentation AT+COLP Connected Line Identification Presentation Response +COLP: (list of supported s) OK Test Command AT+COLP=? Parameters See Write Command Read Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 79 2015-08-03 +COLP: , OK If error is related to ME functionality: +CME ERROR: AT+COLP? Parameters See Write Command Response TA enables or disables the presentation of the COL (Connected Line) at the TE for a mobile originated call. It has no effect on the execution of the supplementary service COLR in the network. Intermediate result code is returned from TA to TE before any +CR or V.25ter responses. OK If error is related to ME functionality: +CME ERROR: Parameters (parameter sets/shows the result code presentation status in the TA): 0 Disable +COLP notification 1 Enable +COLP notification (parameter shows the subscriber COLP service status in the network): 0 COLP not provisioned 1 COLP provisioned 2 Unknown (e.g. no network, etc.) Intermediate result code When enabled (and called subscriber allows), an intermediate result code is returned before any +CR or V.25ter responses: +COLP: ,[,, ,] Write Command AT+COLP= Parameters String type (string should be included in quotation marks) phone number of format specified by Type of address octet in integer format; 129 Unknown type 161 National number type 145 International number type 177 Network specific number String type (string should be included in quotation marks) sub address of format specified by Type of sub address octet in integer format (refer GSM 04.08 [8] sub clause 10.5.4.8) String type (string should be included in quotation marks) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 80 2015-08-03 alphanumeric representation of corresponding to the entry found in phone book. Parameter Saving Mode NO_SAVE Max Response TimeReference Note 3.2.22 AT+COPS Operator Selection AT+COPS Operator Selection Response TA returns a list of quadruplets, each representing an operator present in the network. Any of the formats may be unavailable and should then be an empty field. The list of operators shall be in order: home network, networks referenced in SIM, and other networks. +COPS: (list of supported,long alphanumeric,short alphanumeric,numeric )s[,,(list of supported s), (list of supported s)] OK If error is related to ME functionality: +CME ERROR: Test Command AT+COPS=? Parameters See Write Command Response TA returns the current mode and the currently selected operator. If no operator is selected, and are omitted. +COPS: [,, ] OK If error is related to ME functionality: +CME ERROR: Read Command AT+COPS? Parameters See Write Command Write Command AT+COPS=,[[,< oper>]] Response TA forces an attempt to select and register the GSM network operator. If the selected operator is not available, no other operator shall be selected (except =4). The selected operator name format shall apply to further read commands (+COPS?).Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 81 2015-08-03 OK If error is related to ME functionality: +CME ERROR: Parameters 0 Unknown 1 Operator available 2 Operator current 3 Operator forbidden Refer to [27.007] operator in format as per 0 Automatic mode; field is ignored 1 Manual ( field shall be present, and optionally) 2 manual deregister from network 3 set only (for read Command +COPS?) - not shown in Read Command response 4 Manual/automatic ( field shall be present); if manual selection fails, automatic mode (=0) is entered 0 Long format alphanumeric 1 Short format alphanumeric 2 Numeric ; GSM Location Area Identification number Parameter Saving Mode AUTO_SAVE Max Response Time Test command: 45 seconds Write command: 120 seconds Reference 3GPP TS 27.007 [14] Note 3.2.23 AT+CPAS Phone Activity Status AT+CPAS Phone Activity Status Response +CPAS: (list of supported s) OK Test Command AT+CPAS=? Parameters See Execution Command Execution Command AT+CPAS Response TA returns the activity status of ME. +CPAS: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 82 2015-08-03 OK If error is related to ME functionality: +CME ERROR: Parameters 0 Ready (MT allows commands from TA/TE) 2 Unknown (MT is not guaranteed to respond to tructions) 3 Ringing (MT is ready for commands from TA/TE, but the ringer is active) 4 Call in progress (MT is ready for commands from TA/TE, a call is in progress) Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.24 AT+CPBF Find Phonebook Entries AT+CPBF Find Phonebook Entries Response +CPBF: maximum length of field ,maximum length of field OK If error is related to ME functionality: +CME ERROR: Test Command AT+CPBF=? Parameters See Write Command Response TA returns phone book entries(from the current phone book memory storage selected with +CPBS) which contains alphanumeric string . [+CPBF:,,,] [[…]+CBPF:,,,] OK Write Command AT+CPBF=[] Parameters String type(string should be included in quotation marks) field of maximum length in current TE character set specified by Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 83 2015-08-03 +CSCS. Integer type values in the range of location numbers of phone book memory Integer type values in the range of location numbers of phone book memory String type (string should be included in quotation marks) phone number of format Type of address octet in integer format ; 129 Unknown type 145 International number type String type (string should be included in quotation marks) field of maximum length in current TE character set specified by +CSCS. Integer type value indicating the maximum length of field Integer type value indicating the maximum length of field Parameter Saving Mode NO_SAVE Max Response Time 30 seconds (complete reading of a 250 records full phonebook) 3 seconds(string present in a 250 records full phonebook) 1 second(string not present) We use the China Mobile sim cards for testing, which produced by Axalto at 2010 for Shanghai. Use other sim cards may have different results. Reference 3GPP TS 27.007 [13] Note 3.2.25 AT+CPBR Read Current Phonebook Entries AT+CPBR Read Current Phonebook Entries Response TA returns location range supported by the current storage as a compound value and the maximum lengths of and fields. +CPBR: (list of supported s), , OK Test Command AT+CPBR=? Parameters Location number Max. length of phone number Max. length of text for number Write Command AT+CPBR=<inde Response TA returns phone book entries in location number range ... Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 84 2015-08-03 from the current phone book memory storage selected with +CPBS. If is left out, only location is returned. +CPBR:,,, [[…]+CPBR: , , , ] OK x1>[,] Parameters Read as of this location number Read to this location number Phone number Type of number Text for phone number in current TE character set specified by +CSCS. Parameter Saving Mode NO_SAVE Max Response Time 3 seconds (single reading) 30 seconds (complete reading of a 250 records full phonebook. We use the China Mobile sim cards for testing, which produced by Axalto at 2010 for Shanghai. Use other sim cards may have different results. Reference 3GPP TS 27.007 [13] Note 3.2.26 AT+CPBS Select Phonebook Memory Storage AT+CPBS Select Phonebook Memory Storage Response +CPBS: (list of supported s) OK Test Command AT+CPBS=? Parameters See Write Command Response +CPBS: ,, OK Read Command AT+CPBS? Parameters See Write Command Write Command AT+CPBS= Response TA selects current phone book memory storage, which is used by other phone book commands. OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 85 2015-08-03 Parameters "ON" SIM (or MT) own numbers (MSISDNs) list (reading of this storage may be available through +CNUM also). When storing information in the SIM/UICC, if a SIM card is present or if a UICC with an active GSM application is present, the information in EFMSISDN under DFTelecom is selected. "SM" SIM/UICC phonebook. If a SIM card is present or if a UICC with an active GSM application is present, the EFADN under DFTelecom is selected. "ME" ME phonebook "FD" SIM fix dialing-phone book. If a SIM card is present or if a UICC with an active GSM application is present, the information in EFFDN under DFTelecom is selected Integer type value indicating the total number of used locations in selected memory Integer type value indicating the total number of locations in selected memory Parameter Saving Mode NO_SAVE Max Response Time 3 seconds Reference 3GPP TS 27.007 [13] Note 3.2.27 AT+CPBW Write Phonebook Entry AT+CPBW Write Phonebook Entry Response TA returns location range supported by the current storage, the maximum length of field, supported number formats of the storage, and the maximum length of field. +CPBW: (list of supported s), , (list of supported s), OK Test Command AT+CPBW=? Parameters See Write Command Write Command AT+CPBW=<inde Response TA writes phone book entry in location number in the current Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 86 2015-08-03 phone book memory storage selected with +CPBS. Entry fields written are phone number (in the format ) and text associated with the number. If those fields are omitted, phone book entry is deleted. If is left out, but is given, entry is written to the first free location in the phone book. OK x>[,,[,[]]] Parameters Max length of phone number Max length of text for number Location number Phone number Type of number; 129 National number type 145 International number type String type (string should be included in quotation marks): text for phone number in current TE character set specified by +CSCS. Note: The following characters in must be entered via the escape sequence: GSM char. Seq. Seq.(hex) Note \ \5C 5C 35 43 (backslash) " \22 5C 32 32 (string delimiter) BSP \08 5C 30 38 (backspace) NULL \00 5C 30 30 (GSM null) ‘0’ (GSM null) may cause problems for application layer software when reading string lengths. Parameter Saving Mode NO_SAVE Max Response Time 3 seconds Reference 3GPP TS 27.007 [13] Note 3.2.28 AT+CPIN Enter PIN AT+CPIN Enter PIN Test Command AT+CPIN=? Response OK Read Command AT+CPIN? Response TA returns an alphanumeric string indicating whether some password is required or not. +CPIN: OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 87 2015-08-03 Parameters READY MT is not pending for any password SIM PIN MT is waiting SIM PIN to be given SIM PUK MT is waiting for SIM PUK to be given PH_SIM PIN ME is waiting for phone to SIM card (antitheft) PH_SIM PUK ME is waiting for SIM PUK (antitheft) SIM PIN2 PIN2, e.g. for editing the FDN book possible only if preceding Command was acknowledged with +CME ERROR:17 SIM PUK2 Possible only if preceding Command was acknowledged with error +CME ERROR: 18. Response TA stores a password which is necessary before it can be operated (SIM PIN, SIM PUK, PH-SIM PIN, etc.). If the PIN required is SIM PUK or SIM PUK2, the second pin is required. This second pin, , is used to replace the old pin in the SIM. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CPIN=[ ,] Parameters String type; password String type; If the PIN required is SIM PUK or SIMPUK2: new password Parameter Saving Mode NO_SAVE Max Response Time 5s Reference 3GPP TS 27.007 [13] Note 3.2.29 AT+CPWD Change Password AT+CPWD Change Password Response TA returns a list of pairs which present the available facilities and the maximum length of their password. +CPWD: (list of supported s, list of supported s) OK Test Command AT+CPWD=? Parameters See Write Command Integer max. length of password Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 88 2015-08-03 Response TA sets a new password for the facility lock function. OK Write Command AT+CPWD=<fac,, Parameters"AO" BAOC (Barr All Outgoing Calls) "OI" BOIC (Barr Outgoing International Calls) "OX" BOIC-exHC (Barr Outgoing International Calls except to Home Country) "AI" BAIC (Barr All Incoming Calls) "IR" BIC-Roam (Barr Incoming Calls when Roaming outside the home country) "AB" All Barring services "P2" SIM PIN2 "SC" SIM (lock SIM/UICC card) (SIM/UICC asks password in MT power-up and when this lock command issued) Correspond to PIN1 code. String type (string should be included in quotation marks): password specified for the facility from the user interface or with command. If an old password has not yet been set, is not to enter. String type (string should be included in quotation marks): new password Parameter Saving Mode NO_SAVE Max Response Time 15s Reference 3GPP TS 27.007 [13] Note 3.2.30 AT+CR Service Reporting Control AT+CR Service Reporting Control Response +CR: (list of supported s) OK Test Command AT+CR=? Parameters See Write Command Read Command AT+CR? Response +CR: OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 89 2015-08-03 Parameters See Write Command Response TA controls whether or not intermediate result code +CR: is returned from the TA to the TE at a call set up. OK Parameters 0 Disable 1 Enable Intermediate result code If enabled, an intermediate result code is transmitted at the point during connect negotiation at which the TA has determined which speed and quality of service will be used, before any error control or data compression reports are transmitted, and before any final result code (e.g. CONNECT) is transmitted. +CR: Write Command AT+CR=[<mode] Parameters ASYNC Asynchronous transparent SYNC Synchronous transparent REL ASYNC Asynchronous non-transparent REL SYNC Synchronous non-transparent GPRS For GPRS Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.31 AT+CRC Set Cellular Result Codes for Incoming Call Indication AT+CRC Set Cellular Result Codes for Incoming Call Indication Response +CRC: (list of supported s) OK Test Command AT+CRC=? Parameters See Write Command Read Command AT+CRC? Response +CRC: OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 90 2015-08-03 Parameters See Write Command Response TA controls whether or not the extended format of incoming call indication is used. OK Parameters 0 Disable extended format 1 Enable extended format Omitted Use previous value Unsolicited Result Code When enabled, an incoming call is indicated to the TE with unsolicited result code +CRING: instead of the normal RING. Write Command AT+CRC=[] Parameters ASYNC Asynchronous transparent SYNC Synchronous transparent REL ASYNC Asynchronous non-transparent REL SYNC Synchronous non-transparent FAX Facsimile VOICE Voice Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.32 AT+CREG Network Registration AT+CREG Network Registration Response +CREG: (list of supported s) OK Test Command AT+CREG=? Parameters See Write Command Read Command AT+CREG? Response TA returns the status of result code presentation and an integer which shows whether the network has currently indicated the registration of the ME. Location information elements and are returned only when =2 and ME is registered in the network. +CREG: ,[,,] Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 91 2015-08-03 OK If error is related to ME functionality: +CME ERROR: Response TA controls the presentation of an unsolicited result code +CREG: when =1 and there is a change in the ME network registration status. OK Parameters 0 Disable network registration unsolicited result code 1 Enable network registration unsolicited result code +CREG: 2 Enable network registration unsolicited result code with location information +CREG: [,,] 0 Not registered, MT is not currently searching a new operator to register to 1 Registered, home network 2 Not registered, but MT is currently searching a new operator to register to 3 Registration denied 4 Unknown 5 Registered, roaming String type (string should be included in quotation marks); two byte location area code in hexadecimal format String type (string should be included in quotation marks); two byte cell ID in hexadecimal format Unsolicited Result Code If =1 and there is a change in the MT network registration status +CREG: If =2 and there is a change in the MT network registration status or a change of the network cell: +CREG: [,,] Write Command AT+CREG=[ ] Parameters See Write Command Parameter Saving Mode AT&W_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 92 2015-08-03 3.2.33 AT+CRLP Select Radio Link Protocol Parameters AT+CRLP Select Radio Link Protocol Parameters Response TA returns values supported. RLP versions 0 and 1 share the same parameter set. +CRLP: (list of supported s),(list of supported s),(list of supported s),(list of supported s),(list of supported s) OK Test Command AT+CRLP=? Parameters See Write Command Response TA returns current settings for RLP version. RLP versions 0 and 1 share the same parameter set. +CRLP: ,,,, OK Read Command AT+CRLP? Parameters See Write Command Response TA sets radio link protocol (RLP) parameters used when non-transparent data calls are setup. OK Write Command AT+CRLP=<iws[,[,[ ,[,]]]] Parameters 0-61 Interworking window size (IWF to MS) 0-61 Mobile window size(MS to IWF) 44-255 Acknowledgment timer T1 in 10 ms units 1-255 Retransmission attempts N2 7 Re-sequencing period in integer format, in units of 10 ms. Parameter Saving Mode AT&W_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Simcom redefine param`s value range 3.2.34 AT+CRSM Restricted SIM Access AT+CRSM Restricted SIM Access Test Command AT+CRSM=? Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 93 2015-08-03 Response +CRSM: , [,] OK ERROR If error is related to ME functionality: +CME ERROR: Write Command AT+CRSM=[,<fileId[,,,<P 3>[,]]] Parameters176 READ BINARY 178 READ RECORD 192 GET RESPONSE 214 UPDATE BINARY 220 UPDATE RECORD 242 STATUS All other values are reserved; refer GSM 11.11. Integer type; this is the identifier for an elementary data file on SIM. Mandatory for every Command except STATUS ,, Integer type, range 0 – 255 Parameters to be passed on by the ME to the SIM; refer GSM 11.11. Information which shall be written to the SIM (hex-decimal character format) , Integer type, range 0 - 255 Status information from the SIM about the execution of the actual Command. These parameters are delivered to the TE in both cases, on successful or failed execution of the Command; refer GSM 11.11. Response of a successful completion of the Command previously issued (hexadecimal character format) Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 GSM 11.11 Note 3.2.35 AT+CSQ Signal Quality Report AT+CSQ Signal Quality Report Test Command AT+CSQ=? Response +CSQ: (list of supported s),(list of supported s) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 94 2015-08-03 OK Response +CSQ: , OK If error is related to ME functionality: +CME ERROR: Execution Command returns received signal strength indication and channel bit error rate from the ME. Test Command returns values supported by the TA. Execution Command AT+CSQ Parameters 0 -115 dBm or less 1 -111 dBm 2...30 -110... -54 dBm 31 -52 dBm or greater 99 not known or not detectable (in percent): 0...7 As RXQUAL values in the table in GSM 05.08 [20] subclause 7.2.4 99 Not known or not detectable Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.36 AT+VTD Tone Duration AT+VTD Tone Duration Response +VTD: (list of supported s) OK Test Command AT+VTD=? Parameters See Write Command Response +VTD: OK Read Command AT+VTD? Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 95 2015-08-03 See Write Command Response This command refers to an integer that defines the length of tones emitted as a result of the +VTS command. This does not affect the D command. OK Write Command AT+VTD= Parameters 1-255 Duration of the tone in 1/10 seconds Parameter Saving Mode AT&W_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.37 AT+VTS DTMF and Tone Generation AT+VTS DTMF and Tone Generation Response +VTS: (list of supported s),(list of supported s) OK Test Command AT+VTS=? Parameters See Write Command Write Command Generate tone Duration is set by +VTD AT+VTS= Response This Command allows the transmission of DTMF tones and arbitrary tones in voice mode. These tones may be used (for example) when announcing the start of a recording period. Note: D is used only for dialing. OK If error is related to ME functionality: +CME ERROR: Note: The Command is writing only. Parameters Which has a max length of 20 characters, must be entered between double quotes ("") and consists of combinations of the following separated by commas. But a single character does not require quotes.A single ASCII characters in the set 0-9, #,*, A-D. This is interpreted as a sequence of DTMF tones whose duration is set by the +VTD Command.{, } This is interpreted as a DTMF tone Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 96 2015-08-03 whose duration is determined by . Duration of the tone in 1/10 seconds range :1-255 Parameter Saving Mode NO_SAVE Max Response Time Number of DTMF characters*duration. Reference 3GPP TS 27.007 [13] Note 3.2.38 AT+CMUX Multiplexer Control AT+CMUX Multiplexer Control Response +CMUX: (0) OK Test Command AT+CMUX=? Parameters See Write Command Response: +CMUX:[[,[,<port_speed>[,[,[,[,<T2[,[,]]]]]]]]] OK ERROR Read Command AT+CMUX? Parameters Multiplexer transparency mechanism 0 Basic option The way in which the multiplexer control channel is set up 0 UIH frames used only <port_speed> Transmission rate 1 9600 bits/t 2 19200 bits/t 3 38400 bits/t 4 57600 bits/t 5 115200 bit/s 6 230400 bits/t 7 460800 bits/t Proprietary values, available if MUX NEW PORT SPEED FTR is activated Maximum frame size 1-255 Default: 127 Acknowledgement timer in units of ten milliseconds 1-255 Default:10 (100 ms) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 97 2015-08-03 Maximum number of re-transmissions 0-100 Default:3 Max Response Timer for the multiplexer control channel in units of ten milliseconds 2-255 Default:30 Wake up Max Response Timers in seconds 1-255 Default:10 Window size, for Advanced operation with Error Recovery options 1-7 Default:2 Response If error is related to ME functionality: +CME ERROR: Write Command AT+CMUX= Parameters Multiplexer transparency mechanism 0 Basic option Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note The multiplexing transmission rate is according to the current serial baud rate. It is recommended to enable multiplexing protocol under 115200 bit/s baud rate Multiplexer control channels are listed as follows: Channel Number Type DLCI None Multiplexer Control 0 1 3GPP TS 27.007 and 005 1 2 3GPP TS 27.007 and 005 2 3 3GPP TS 27.007 and 005 3 4 3GPP TS 27.007 and 005 4 3.2.39 AT+CNUM Subscriber Number AT+CNUM Subscriber Number Test Command AT+CNUM=? Response OK Execution Command AT+CNUM Response +CNUM: [],,[,,] [+CNUM:[],,[,,] [...]] Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 98 2015-08-03 OK If error is related to ME functionality: +CME ERROR: Parameters Optional alphanumeric string associated with ; used character set should be the one selected with Command Select TE Character Set +CSCS String type (string should be included in quotation marks) phone number of format specified by Type of address octet in integer format (refer GSM04.08[8] subclause 10.5.4.7) As defined by the +CBST Command (service related to the phone number:) 0 Asynchronous modem 1 Synchronous modem 2 PAD Access (asynchronous) 3 Packet Access (synchronous) 4 Voice 5 Fax Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.40 AT+CPOL Preferred Operator List AT+CPOL Preferred Operator List Response +CPOL: (list of supported s),(list of supported s) OK Test Command AT+CPOL=? Parameters See Write Command Read Command AT+CPOL? Response +CPOL: ,, [+CPOL: ,,[…]] OK If error is related to ME functionality: +CME ERROR: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 99 2015-08-03 Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CPOL=[,,] Parameters Integer type: order number of operator in SIM preferred operator list Indicates whether alphanumeric or numeric format used (see +COPS Command) 0 Long format alphanumeric 1 Short format alphanumeric 2 Numeric String type(string should be included in quotation marks) Parameter Saving Mode AUTO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.41 AT+COPN Read Operator Names AT+COPN Read Operator Names Test Command AT+COPN=? Response OK Response +COPN: , [+COPN: , […]] OK If error is related to ME functionality: +CME ERROR: Execution Command AT+COPN Parameters String type (string should be included in quotation marks): operator in numeric format (see +COPS) String type (string should be included in quotation marks): operator in long alphanumeric format (see +COPS) Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 100 2015-08-03 Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.42 AT+CFUN Set Phone Functionality AT+CFUN Set Phone Functionality Response +CFUN: (list of supported s),(list of supported s) OK If error is related to ME functionality: +CME ERROR: Test Command AT+CFUN=? Parameters See Write Command Response +CFUN: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CFUN? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CFUN=<fun[,] Parameters 0 Minimum functionality 1 Full functionality (Default) 4 Disable phone both transmit and receive RF circuits. 1 Reset the MT before setting it to power level. Parameter Saving Mode AUTO_SAVE Max Response Time 10s Reference 3GPP TS 27.007 [13] Note Minimum functionality mode (AT+CFUN=0)and RF disabled functionality mode (AT+CFUN=4) cannot be switched to each other. The power level will be written to flash except minimum functionality. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 101 2015-08-03 AT+CFUN=1,1 can be used to reset module purposely at minimum/full functionality mode. Response string "OK" will be returned after module resets if baud rate is set to fixed baud rate. 3.2.43 AT+CCLK Clock AT+CCLK Clock Test Command AT+CCLK=? Response OK Response +CCLK: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CCLK? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CCLK= Parameters String type(string should be included in quotation marks) value; format is "yy/MM/dd,hh:mm:ss±zz", where characters indicate year (two last digits),month, day, hour, minutes, seconds and time zone (indicates the difference, expressed in quarters of an hour, between the local time and GMT; range -47...+48). E.g. 6th of May 2010, 00:01:52 GMT+2 hours equals to "10/05/06,00:01:52+08". Parameter Saving Mode AUTO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note Only time zone is auto saved. 3.2.44 AT+CSIM Generic SIM Access AT+CSIM Generic SIM Access Test Command AT+CSIM=? Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 102 2015-08-03 Response +CSIM: , OK If error is related to ME functionality: +CME ERROR: Write Command AT+CSIM=, Parameters Integer type: length of characters sent to the TE in or (i.e. twice the number of octets in the raw data). String type (string should be included in quotation marks): hex format: GSM 11.11 SIM Command sent from the ME to the SIM. String type(string should be included in quotation marks): hex format: GSM 11.11 response from SIM to . Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.45 AT+CALM Alert Sound Mode AT+CALM Alert Sound Mode Response +CALM: (list of supported s) OK If error is related to ME functionality: +CME ERROR: Test Command AT+CALM=? Parameters See Write Command Response +CALM: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CALM? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 103 2015-08-03 Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CALM= Parameters 0 Normal mode 1 Silent mode (all sounds from ME are prevented) Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note If CALM is set to silent mode before, when user sets CALM to normal mode during an incoming call, the module maintains silent this time. But next time the normal mode works. 3.2.46 AT+CALS Alert Sound Select AT+CALS Alert Sound Select Response +CALS: (list of supported s),(list of supported s) OK If error is related to ME functionality: +CME ERROR: Test Command AT+CALS=? Parameters See Write Command Response +CALS: , OK If error is related to ME functionality: +CME ERROR: Read Command AT+CALS? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CALS=[, ] Parameters 0-19 Alert sound type 0 stop playing ring tone 1 start to play ring tone Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 104 2015-08-03 Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 3.2.47 AT+CRSL Ringer Sound Level AT+CRSL Ringer Sound Level Response +CRSL: (list of supported s) OK If error is related to ME functionality: +CME ERROR: Test Command AT+CRSL=? Parameter See Write Command Response +CRSL: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CRSL? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CRSL= Parameters integer type value (0-100) with manufacturer specific range Parameter Saving Mode AUTO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.48 AT+CLVL Loud Speaker Volume Level AT+CLVL Loud Speaker Volume Level Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 105 2015-08-03 Response +CLVL: (list of supported s) OK If error is related to ME functionality: +CME ERROR: Test Command AT+CLVL=? Parameters See Write Command Response +CLVL: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CLVL? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CLVL= Parameters 0-100 Integer type value with manufacturer specific range (smallest value represents the lowest sound level). Parameter Saving Mode AUTO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3.2.49 AT+CMUT Mute Control AT+CMUT Mute Control Response +CMUT: (list of supported s) OK Test Command AT+CMUT=? Parameters See Write Command Read Command AT+CMUT? Response +CMUT: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 106 2015-08-03 OK If error is related to ME functionality: +CME ERROR: Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CMUT= Parameters 0 Mute off 1 Mute on Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note Only during a call this command can be set successfully. 3.2.50 AT+CPUC Price Per Unit and Currency Table AT+CPUC Price Per Unit and Currency Table Test Command AT+CPUC=? Response OK Response +CPUC: , OK If error is related to ME functionality: +CME ERROR: Read Command AT+CPUC? Parameters See Write Command Response OK +CME ERROR: Write Command AT+CPUC=,[,< passwd>] Parameters String type (string should be included in quotation marks); three-character currency code (e.g. "GBP", "DEM");character set as specified by "AT+CSCS" command String type (string should be included in quotation marks); price Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 107 2015-08-03 per unit; dot is used as a decimal separator(e.g. "2.66") String type (string should be included in quotation marks); SIM PIN2 Parameter Saving Mode NO_SAVE Max Response Time 5s Reference 3GPP TS 27.007 [13] Note 3.2.51 AT+CCWE Call Meter Maximum Event AT+CCWE Call Meter Maximum Event Response +CCWE: (list of supported s) OK If error is related to ME functionality: +CME ERROR: Test Command AT+CCWE=? Parameters See Write Command Response +CCWE: OK If error is related to ME functionality: +CME ERROR: Read Command AT+CCWE? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Parameters 0 Disable call meter warning event 1 Enable call meter warning event Write Command AT+CCWE= Unsolicited result codes supported: +CCWV Shortly before the ACM (Accumulated Call Meter) maximum value is reached, an unsolicited result code +CCWV will be sent, if enabled by this command. The warning is issued approximately when 5 seconds call time remains. It is also issued when starting a call if less than 5 s call time remains. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 108 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note 3GPP TS 27.007 specifies 30 seconds, so SIMCom deviates from the specification. 3.2.52 AT+CBC Battery Charge AT+CBC Battery Charge Response +CBC: (list of supported s),(list of supported s),() OK Test Command AT+CBC=? Parameters See Execution Command Response +CBC: , , OK If error is related to ME functionality: +CME ERROR: Execution Command AT+CBC Parameters Charge status 0 ME is not charging 1 ME is charging 2 Charging has finished Battery connection level 1...100 battery has 1-100 percent of capacity remaining vent Battery voltage(mV) Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.007 [13] Note This command depends on hardware and only be used when battery is charging. 3.2.53 AT+CUSD Unstructured Supplementary Service Data AT+CUSD Unstructured Supplementary Service Data Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 109 2015-08-03 Response +CUSD: (list of supported s) OK Test Command AT+CUSD=? Parameters See Write Command Response +CUSD: OK Read Command AT+CUSD? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CUSD=[, [,]] Parameters A numeric parameter which indicates control of the unstructured supplementary service data 0 disable the result code presentation in the TE 1 enable the result code presentation in the TE 2 cancel session (not applicable to read Command response) String type (string should be included in quotation marks) USSD-string Cell Broadcast Data Coding Scheme in integer format (default 0) Parameter Saving Mode NO_SAVE Max Response TimeReference GSM 03.38 [25] Note When ussd is not suport or return error,TE will print +CUSD:4. 3.2.54 AT+CSSN Supplementary Services Notification AT+CSSN Supplementary Services Notification Response +CSSN: (list of supported s),(list of supported s) OK Test Command AT+CSSN=? Parameters See Write Command Read Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 110 2015-08-03 +CSSN: , OK AT+CSSN? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CSSN=[, ] Parameters A numeric parameter which indicates whether to show the +CSSI:[,] result code presentation status after a mobile originated call setup 0 disable 1 enable A numeric parameter which indicates whether to show the +CSSU: result code presentation status during a mobile terminated call setup or during a call, or when a forward check supplementary service notification is received. 0 disable 1 enable 0 Unconditional call forwarding is active 1 Some of the conditional call forwarding are active 2 Call has been forwarded 3 Call is waiting 4 This is a CUG call (also present) 5 Outgoing calls are barred 6 Incoming calls are barred 7 CLIR suppression rejected Closed user group index 0 This is a forwarded call 1 This is a CUG call (also present) (MT call setup) 2 Call has been put on hold (during a voice call) 3 Call has been retrieved (during a voice call) 4 Multiparty call entered (during a voice call) 5 Call on hold has been released (this is not a SS notification) (during a voice call) 6 Forward check SS message received (can be received whenever) 7 Call is being connected (alerting) with the remote party in alerting state in explicit call transfer operation (during a voice call) 8 Call has been connected with the other remote party in explicit call transfer operation (also number and subaddress parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 111 2015-08-03 may be present) (during a voice call or MT call setup) 9 This is a deflected call (MT call setup) Parameter Saving Mode NO_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 112 2015-08-03 4 AT Commands According to 3GPP TS 27.005 The 3GPP TS 27.005 commands are for performing SMS and CBS related operations. SIM800 Series supports both Text and PDU modes. 4.1 Overview of AT Commands According to 3GPP TS 27.005 Command Description AT+CMGD Delete SMS message AT+CMGF Select SMS message format AT+CMGL List SMS messages from preferred store AT+CMGR Read SMS message AT+CMGS Send SMS message AT+CMGW Write SMS message to memory AT+CMSS Send SMS message from storage AT+CNMI New SMS message indications AT+CPMS Preferred SMS message storage AT+CRES Restore SMS settings AT+CSAS Save SMS settings AT+CSCA SMS service center address AT+CSCB Select cell broadcast SMS messages AT+CSDH Show SMS text mode parameters AT+CSMP Set SMS text mode parameters AT+CSMS Select message service 4.2 Detailed Descriptions of AT Commands According to 3GPP TS 27.005 4.2.1 AT+CMGD Delete SMS Message AT+CMGD Delete SMS Message Response +CMGD: (list of supported s),(list of supported s) OK Test Command AT+CMGD=? Parameters See Write Command Write Command AT+CMGD=[,] Response TA deletes message from preferred message storage location . OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 113 2015-08-03 ERROR If error is related to ME functionality: +CMS ERROR: Parameters Integer type; value in the range of location numbers supported by the associated memory 0 Delete the message specified in 1 Delete all read messages from preferred message storage, leaving unread messages and stored mobile originated messages (whether sent or not) untouched 2 Delete all read messages from preferred message storage and sent mobile originated messages, leaving unread messages and unsent mobile originated messages untouched 3 Delete all read messages from preferred message storage, sent and unsent mobile originated messages leaving unread messages untouched 4 Delete all messages from preferred message storage including unread messages Parameter Saving Mode NO_SAVE Max Response Time 5s(delete 1 message) 25s(delete 50 messages) 25s(delete 150 messages) Reference 3GPP TS 27.005 Note 4.2.2 AT+CMGF Select SMS Message Format AT+CMGF Select SMS Message Format Response +CMGF: (list of supported s)OK Test Command AT+CMGF=? Parameter See Write Command Response +CMGF: OK Read Command AT+CMGF? Parameter See Write Command Write Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 114 2015-08-03 TA sets parameter to denote which input and output format of messages to use. OK AT+CMGF=[] Parameter 0 PDU mode 1 Text mode Parameter Saving Mode AT&W_SAVE Max Response TimeReference 3GPP TS 27.005 Note 4.2.3 AT+CMGL List SMS Messages from Preferred Store AT+CMGL List SMS Messages from Preferred Store Response +CMGL: (list of supported s) OK Test Command AT+CMGL=? Parameter See Write Command ParametersIf text mode: "REC UNREAD" Received unread messages "REC READ" Received read messages "STO UNSENT" Stored unsent messages "STO SENT" Stored sent messages "ALL" All messages 0 Normal 1 Not change status of the specified SMS recordIf PDU mode: 0 Received unread messages 1 Received read messages 2 Stored unsent messages 3 Stored sent messages 4 All messages 0 Normal 1 Not change status of the specified SMS record Write Command AT+CMGL=[,] Response TA returns messages with status value from message storage to the TE. If status of the message is 'received unread', status in the storage changes to 'received read'. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 115 2015-08-03If text mode (+CMGF=1) and Command successful: for SMS-SUBMITs and/or SMS-DELIVERs: +CMGL: ,,<oa/da>[,][,] [,<tooa/toda>,] [+CMGL: ,,<da/oa> [,][,][,<tooa/toda>,][...]] for SMS-STATUS-REPORTs: +CMGL: ,,,[,][,],,, [+CMGL: ,,, [,][,],,,[...]] for SMS-COMMANDs: +CMGL: ,,,[ +CMGL: ,,,[...]] for CBM storage: +CMGL:,,,,, +CMGL: ,,,,, [...]] OKIf PDU mode (+CMGF=0) and Command successful: +CMGL:,[,], +CMGL: ,[,alpha], [...]] OK 3)If error is related to ME functionality: +CMS ERROR: Parameters String type(string should be included in quotation marks) alphanumeric representation of or corresponding to the entry found in MT phonebook; implementation of this feature is manufacturer specific; used character set should be the one selected with Command Select TE Character Set +CSCS (see definition of this Command in 3GPP TS 27.007) GSM 03.40 TP-Destination-Address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (refer Command+CSCS in 3GPP TS 27.007); type of address given by In the case of SMS: GSM 03.40 TP-User-Data in text mode responses; format:if indicates that GSM 03.38 default alphabet is used and Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 116 2015-08-03 indicates that GSM 03.40 TPUser-Data-Header-Indication is not set:if TE character set other than "HEX" (refer Command Select TE Character Set +CSCS in 3GPP TS 27.007):ME/TA converts GSM alphabet into current TE character set according to rules of Annex Aif TE character set is "HEX": ME/TA converts each 7-bit character of GSM alphabet into two IRA character long hexadecimal number (e.g. character P (GSM 23) is presented as 17 (IRA 49 and 55))if indicates that 8-bit or UCS2 data coding scheme is used, or indicates that GSM 03.40 TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA character long hexadecimal number (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)) In the case of CBS: GSM 03.41 CBM Content of Message in text mode responses; format:if indicates that GSM 03.38 default alphabet is used:if TE character set other than "HEX" (refer Command +CSCS in 3GPP TS 27.007): ME/TA converts GSM alphabet into current TE character set according to rules of Annex Aif TE character set is "HEX": ME/TA converts each 7-bit character of GSM alphabet into two IRA character long hexadecimal numberif indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each 8-bit octet into two IRA character long hexadecimal number Integer type value indicating in the text mode (+CMGF=1) the length of the message body (or ) in characters; or in PDU mode (+CMGF=0), the length of the actual TP data unit in octets (i.e. the RP layer SMSC address octets are not counted in the length) Integer type; value in the range of location numbers supported by the associated memory GSM 03.40 TP-Originating-Address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (refer Command +CSCS in 3GPP TS 27.007); type of address given by In the case of SMS: GSM 04.11 SC address followed by GSM 03.40 TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal number (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)). In the case of CBS: GSM 03.41 TPDU in hexadecimal format. GSM 03.40 TP-Service-Center-Time-Stamp in time-string format (refer) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 117 2015-08-03 GSM 04.11 TP-Destination-Address Type-of-Address octet in integer format (when first character of is + (IRA 43) default is 145, otherwise default is 129) GSM 04.11 TP-Originating-Address Type-of-Address octet in integer format (default refer)If text mode: the same as AT+CMGL="REC UNREAD", received unread messagesIf PDU mode: the same as AT+CMGL=0, received unread messages See more messages please refer to Write Command. Execution Command AT+CMGL Parameters See Write Command Parameter Saving Mode NO_SAVE Max Response Time 20s(list 50 messages) 20s(list 150 messages) Reference 3GPP TS 27.005 Note 4.2.4 AT+CMGR Read SMS Message AT+CMGR Read SMS Message Test Command AT+CMGR=? Response OK Parameters Integer type; value in the range of location numbers supported by the associated memory 0 Normal 1 Not change status of the specified SMS record Write Command AT+CMGR=[,] Response TA returns SMS message with location value from message storage to the TE. If status of the message is 'received unread', status in the storage changes to 'received read'.If text mode (+CMGF=1) and Command successful: for SMS-DELIVER: +CMGR: ,[,],[,,,, ,,,] for SMS-SUBMIT: +CMGR: ,[,][,,,,[,] ,,,] for SMS-STATUS-REPORTs: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 118 2015-08-03 +CMGR: ,,[,][,],,, for SMS-COMMANDs: +CMGR: ,,[,[,][,][,] ,] for CBM storage: +CMGR: ,,,,,If PDU mode (+CMGF=0) and Command successful: +CMGR: [,], OKIf error is related to ME functionality: +CMS ERROR: Parameters String type (string should be included in quotation marks) alphanumeric representation of or corresponding to the entry found in MT phonebook; implementation of this feature is manufacturer specific GSM 03.40 TP-Destination-Address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (specified by +CSCS in 3GPP TS 27.007); type of address given by In the case of SMS: GSM 03.40 TP-User-Data in text mode responses; format:if indicates that GSM 03.38 default alphabet is used and indicates that GSM 03.40 TPUser-Data-Header-Indication is not set:if TE character set other than "HEX" (refer Command Select TE Character Set +CSCS in 3GPP TS 27.007):ME/TA converts GSM alphabet into current TE character set according to rules of Annex Aif TE character set is "HEX": ME/TA converts each 7-bit character of GSM alphabet into two IRA character long hexadecimal number (e.g. character P (GSM 23) is presented as 17 (IRA 49 and 55))if indicates that 8-bit or UCS2 data coding scheme is used, or indicates that GSM 03.40 TP-User-Data-Header-Indication is set: ME/TA converts each 8-bit octet into two IRA character long hexadecimal number (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)) In the case of CBS: GSM 03.41 CBM Content of Message in text mode responses; format:if indicates that GSM 03.38 default alphabet is used:if TE character set other than "HEX" (refer Command +CSCS in 3GPP TS 27.007): ME/TA converts GSM alphabet into Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 119 2015-08-03 current TE character set according to rules of Annex Aif TE character set is "HEX": ME/TA converts each 7-bit character of GSM alphabet into two IRA character long hexadecimal numberif indicates that 8-bit or UCS2 data coding scheme is used: ME/TA converts each 8-bit octet into two IRA character long hexadecimal number Depending on the Command or result code: GSM 03.38 SMS Data Coding Scheme (default 0), or Cell Broadcast Data Coding Scheme in integer format Depending on the Command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format integer type value indicating in the text mode (+CMGF=1) the length of the message body (or ) in characters; or in PDU mode (+CMGF=0), the length of the actual TP data unit in octets (i.e. the RP layer SMSC address octets are not counted in the length) GSM 03.41 CBM Message Identifier in integer format GSM 03.40 TP-Originating-Address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted characters of the currently selected TE character set (specified by +CSCS in 3GPP TS 27.007); type of address given by In the case of SMS: GSM 04.11 SC address followed by GSM 03.40 TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal number (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)). In the case of CBS: GSM 03.41 TPDU in hexadecimal format. GSM 03.40 TP-Protocol-Identifier in integer format (default 0) GSM 04.11 RP SC address Address-Value field in string format; BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (specified by +CSCS in 3GPP TS 27.007); type of address given by GSM 03.40 TP-Service-Centre-Time-Stamp in time-string format (refer) 0 "REC UNREAD" Received unread messages 1 "REC READ" Received read messages 2 "STO UNSENT" Stored unsent messages 3 "STO SENT" Stored sent messages 4 "ALL" All messages GSM 04.11 TP-Destination-Address Type-of-Address octet in integer format (when first character of is + (IRA 43) default is 145, otherwise default is 129) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 120 2015-08-03 GSM 04.11 TP-Originating-Address Type-of-Address octet in integer format (default refer) GSM 04.11 RP SC address Type-of-Address octet in integer format (default refer ) Depending on SMS-SUBMIT setting: GSM 03.40 TP-Validity-Period either in integer format (default 167) or in time-string format (refer) Parameter Saving Mode NO_SAVE Max Response Time 5s Reference 3GPP TS 27.005 Note 4.2.5 AT+CMGS Send SMS Message AT+CMGS Send SMS Message Test Command AT+CMGS=? Response OK Parameters GSM 03.40 TP-Destination-Address Address-Value field in string format(string should be included in quotation marks); BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (specified by +CSCS in 3GPP TS 27.007); type of address given by GSM 04.11 TP-Destination-Address Type-of-Address octet in integer format (when first character of is + (IRA 43) default is 145, otherwise default is 129) Integer type value (not exceed 160 bytes) indicating in the text mode (+CMGF=1) the length of the message body (or ) in characters; or in PDU mode (+CMGF=0), the length of the actual TP data unit in octets (i.e. the RP layer SMSC address octets are not counted in the length) Write CommandIf text mode (+CMGF=1): +CMGS=[, ] text is entered <ctrl-Z/ESC> ESC quits without sendingIf PDU mode (+CMGF=0): +CMGS=<lengthPDU is given <ctrl-Z/ESC> Response TA sends message from a TE to the network (SMS-SUBMIT). Message reference value is returned to the TE on successful message delivery. Optionally (when +CSMS value is 1 and network supports) is returned. Values can be used to identify message upon unsolicited delivery status report result code.If text mode(+CMGF=1) and sending successful: +CMGS: OKIf PDU mode(+CMGF=0) and sending successful: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 121 2015-08-03 +CMGS: OK 3)If error is related to ME functionality: +CMS ERROR: Parameter GSM 03.40 TP-Message-Reference in integer format Parameter Saving Mode NO_SAVE Max Response Time 60s Reference 3GPP TS 27.005 Note In text mode, the maximum length of an SMS depends on the used coding scheme: It is 1024 characters if the 7 bit GSM coding scheme is used. Reject incoming call when sending messages. 4.2.6 AT+CMGW Write SMS Message to Memory AT+CMGW Write SMS Message to Memory Test Command AT+CMGW=? Response OK Response TA transmits SMS message (either SMS-DELIVER or SMS-SUBMIT) from TE to memory storage . Memory location of the stored message is returned. By default message status will be set to 'stored unsent', but parameter allows also other status values to be given. If writing is successful: +CMGW: OK If error is related to ME functionality: +CMS ERROR: Write CommandIf text mode (+CMGF=1): AT+CMGW=<o a/da>[,<tooa/tod a>][,] text is entered <ctrl-Z/ESC> quits without sendingIf PDU mode (+CMGF=0): AT+CMGW=[,] PDU is given <ctrl-Z/ESC> Parameters GSM 03.40 TP-Originating-Address Address-Value field in string format(string should be included in quotation marks); BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (specified by +CSCS in 3GPP TS 27.007);type of address given by GSM 03.40 TP-Destination-Address Address-Value field in string format(string should be included in quotation marks); BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (specified by +CSCS in 3GPP TS Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 122 2015-08-03 27.007); type of address given by GSM 04.11 TP-Originating-Address Type-of-Address octet in integer format (default refer ) GSM 04.11 TP-Destination-Address Type-of-Address octet in integer format (when first character of is + (IRA 43) default is 145, otherwise default is 129) 129 Unknown type(IDSN format number) 161 National number type(IDSN format) 145 International number type(ISDN format) 177 Network specific number(ISDN format) Integer type value (not exceed 160 bytes) indicating in the text mode (+CMGF=1) the length of the message body (or ) in characters; or in PDU mode (+CMGF=0), the length of the actual TP data unit in octets (i.e. the RP layer SMSC address octets are not counted in the length) in the text mode (+CMGF=1): "STO UNSENT" Stored unsent messages "STO SENT" Stored sent messages in PDU mode (+CMGF=0): 0 Received unread messages 1 Received read messages 2 Stored unsent messages 3 Stored sent messages In the case of SMS: GSM 04.11 SC address followed by GSM 03.40 TPDU in hexadecimal format: ME/TA converts each octet of TP data unit into two IRA character long hexadecimal number (e.g. octet with integer value 42 is presented to TE as two characters 2A (IRA 50 and 65)). In the case of CBS: GSM 03.41 TPDU in hexadecimal format. Index of message in selected storage Execution Command AT+CMGW Response TA transmits SMS message (either SMS-DELIVER or SMS-SUBMIT) from TE to memory storage . Memory location of the stored message is returned. By default message status will be set to 'stored unsent', but parameter allows also other status values to be given. If writing is successful: +CMGW: OK If error is related to ME functionality: +CMS ERROR: Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 123 2015-08-03 Max Response Time 5s Reference 3GPP TS 27.005 Note 4.2.7 AT+CMSS Send SMS Message from Storage AT+CMSS Send SMS Message from Storage Test Command AT+CMSS=? Response OK Response TA sends message with location value from message storage to the network (SMS-SUBMIT). If new recipient address is given, it shall be used instead of the one stored with the message. Reference value is returned to the TE on successful message delivery. Values can be used to identify message upon unsolicited delivery status report result code.If text mode(+CMGF=1) and sending successful: +CMSS: OKIf PDU mode(+CMGF=0) and sending successful: +CMSS: OK 3)If error is related to ME functionality: +CMS ERROR: Write Command AT+CMSS=[,,<toda] Parameters Integer type; value in the range of location numbers supported by the associated memory GSM 03.40 TP-Destination-Address Address-Value field in string format(string should be included in quotation marks); BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (specified by +CSCS in 3GPP TS 27.007); type of address given by GSM 04.11 TP-Destination-Address Type-of-Address octet in integer format (when first character of is + (IRA 43) default is 145, otherwise default is 129) GSM 03.40 TP-Message-Reference in integer format Parameter Saving Mode NO_SAVE Max Response Time 60s Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 124 2015-08-03 3GPP TS 27.005 4.2.8 AT+CNMI New SMS Message Indications AT+CNMI New SMS Message Indications Response +CNMI: (list of supported s),(list of supported s),(list of supported s),(list of supported s),(list of supported s) OK Test Command AT+CNMI=? Parameters See Write Command Response +CNMI: ,,,, OK Read Command AT+CNMI? Parameters See Write Command Response TA selects the procedure for how the receiving of new messages from the network is indicated to the TE when TE is active, e.g. DTR signal is ON. If TE is inactive (e.g. DTR signal is OFF), message receiving should be done as specified in GSM 03.38. OK ERROR Write Command AT+CNMI=[,[,<bm [,[,]]] ] Parameters 0 Buffer unsolicited result codes in the TA. If TA result code buffer is full, indications can be buffered in some other place or the oldest indications may be discarded and replaced with the new received indications. 1 Discard indication and reject new received message unsolicited result codes when TA-TE link is reserved (e.g. in on-line data mode). Otherwise forward them directly to the TE. 2 Buffer unsolicited result codes in the TA when TA-TE link is reserved (e.g. in on-line data mode) and flush them to the TE after reservation. Otherwise forward them directly to the TE. 3 Forward unsolicited result codes directly to the TE. TA-TE link specific inband technique used to embed result codes and data when TA is in on-line data mode. (the rules for storing received SMs depend on its data coding scheme (refer GSM 03.38 [2]), preferred memory storage (+CPMS) setting and this value): 0 No SMS-DELIVER indications are routed to the TE. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 125 2015-08-03 1 If SMS-DELIVER is stored into ME/TA, indication of the memory location is routed to the TE using unsolicited result code: +CMTI: , 2 SMS-DELIVERs (except class 2) are routed directly to the TE using unsolicited result code: +CMT: [], (PDU mode enabled) or +CMT: ,[], [,,,,,,,] (text mode enabled; about parameters in italics, refer Command Show Text Mode Parameters +CSDH). Class 2 messages result in indication as defined in =1. 3 Class 3 SMS-DELIVERs are routed directly to TE using unsolicited result codes defined in =2. Messages of other classes result in indication as defined in =1. (the rules for storing received CBMs depend on its data coding scheme (refer GSM 03.38 [2]), the setting of Select CBM Types (+CSCB) and this value): 0 No CBM indications are routed to the TE. 2 New CBMs are routed directly to the TE using unsolicited result code: +CBM: (PDU mode enabled) or +CBM: ,,,, (text mode enabled). 0 No SMS-STATUS-REPORTs are routed to the TE. 1 SMS-STATUS-REPORTs are routed to the TE using unsolicited result code: +CDS: (PDU mode enabled) or +CDS: ,[,][,],,, (text mode enabled) 0 TA buffer of unsolicited result codes defined within this Command is flushed to the TE when 1...3 is entered (OK response shall be given before flushing the codes). 1 TA buffer of unsolicited result codes defined within this command is cleared when 1…3 is entered Unsolicited result codeIndicates that new message has been received If =1: +CMTI: , If =2 (PDU mode enabled): +CMT: [], If =2 (text mode enabled): +CMT: , [, , , , , , , ]Indicates that new cell broadcast message has been received If =2 (PDU mode enabled): Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 126 2015-08-03 +CBM: If =2 (text mode enabled): +CBM: , , , ,Indicates that new SMS status report has been received If =1 (PDU mode enabled): +CDS: If =1 (text mode enabled): +CDS: , [, ][, ], ,, Parameter Saving Mode AT&W_SAVE Max Response TimeReference 3GPP TS 27.005 Note 4.2.9 AT+CPMS Preferred SMS Message Storage AT+CPMS Preferred SMS Message Storage Response +CPMS: (list of supported s),(list of supported s),(list of supported s) OK Test Command AT+CPMS=? Parameters See Write Command Response +CPMS: ,,,,,, ,, OK ERROR Read Command AT+CPMS? Parameters See Write Command Response TA selects memory storages , and to be used for reading, writing, etc. +CPMS: ,,,,, OK ERROR Write Command AT+CPMS=[,[,< mem3>]] Parameters Messages to be read and deleted from this memory storage Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 127 2015-08-03 "SM" SIM message storage "ME" Phone message storage "SM_P" SM message storage preferred "ME_P" ME message storage preferred "MT" SM or ME message storage ( SM preferred) Messages will be written and sent to this memory storage "SM" SIM message storage "ME" Phone message storage "SM_P" SM message storage preferred "ME_P" ME message storage preferred "MT" SM or ME message storage ( SM preferred) Received messages will be placed in this memory storage if routing to PC is not set ("+CNMI") "SM" SIM message storage "ME" Phone message storage "SM_P" SM message storage preferred "ME_P" ME message storage preferred "MT" SM or ME message storage ( SM preferred) Integer type; Number of messages currently in Integer type; Number of messages storable in Parameter Saving Mode NO_SAVE Max Response TimeReference 3GPP TS 27.005 Note 4.2.10 AT+CRES Restore SMS Settings AT+CRES Restore SMS Settings Response +CRES: (list of supported s)OK Test Command AT+CRES=? Parameter See Write Command Write Command AT+CRES= Response Execution command restores message service settings from non-volatile memory to active memory. A TA can contain several profiles of settings. Settings specified in commands Service Centre Address +CSCA and Set Message Parameters +CSMP are restored. Certain settings may not be supported by the storage (e.g. (U)SIM SMS parameters) and therefore can not be restored. OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 128 2015-08-03 ERROR Parameter 0 Restore SM service settings from profile 0 1 Restore SM service settings from profile 1 2 Restore SM service settings from profile 2 3 Restore SM service settings from profile 3 Execution Command AT+CRES Response Same as AT+CRES=0. OK If error is related to ME functionality: +CMS ERROR Parameter Saving Mode NO_SAVE Max Response Time 5s Reference 3GPP TS 27.005 Note 4.2.11 AT+CSAS Save SMS Settings AT+CSAS Save SMS Settings Response +CSAS: (list of supported s) OK Test Command AT+CSAS=? Parameter See Write Command Response Execution command saves active message service settings to a non-volatile memory. Settings specified in commands Service Centre Address +CSCA and Set Message Parameters +CSMP are saved. Certain settings may not be supported by the storage (e.g. (U)SIM SMS parameters) and therefore can not be saved. OK ERROR Write Command AT+CSAS= Parameter 0 Save SM service setting in profile 0 1 Save SM service setting in profile 1 2 Save SM service setting in profile 2 3 Save SM service setting in profile 3 Execution Command AT+CSAS Response Same as AT+CSAS=0 OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 129 2015-08-03 If error is related to ME functionality: +CMS ERROR Parameter Saving Mode NO_SAVE Max Response Time 5s Reference 3GPP TS 27.005 Note 4.2.12 AT+CSCA SMS Service Center Address AT+CSCA SMS Service Center Address Test Command AT+CSCA=? Response OK Response +CSCA: ,[,] OK Read Command AT+CSCA? Parameters See Write Command Response TA updates the SMSC address, through which mobile originated SMS are transmitted. In text mode, setting is used by send and writes commands. In PDU mode, setting is used by the same commands, but only when the length of the SMSC address coded into parameter equals zero.Note: The Command writes the parameters in NON-VOLATILE memory. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CSCA=<sca[,] Parameters GSM 04.11 RP SC address Address-Value field in string format(string should be included in quotation marks); BCD numbers (or GSM default alphabet characters) are converted to characters of the currently selected TE character set (specified by +CSCS in 3GPP TS 27.007); type of address given by Service center address format GSM 04.11 RP SC address Type-of-Address octet in integer format (default refer ) String type(string should be included in quotation marks) Service center address alpha data Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 130 2015-08-03 Mode Max Response Time 5s Reference 3GPP TS 27.005 Note 4.2.13 AT+CSCB Select Cell Broadcast SMS Messages AT+CSCB Select Cell Broadcast SMS Messages Response +CSCB: (list of supported s) OK Test Command AT+CSCB=? Parameter See Write Command Response +CSCB: ,, OK Read Command AT+CSCB? Parameters See Write Command Response TA selects which types of CBMs are to be received by the ME.Note: The Command writes the parameters in NON-VOLATILE memory. OK If error is related to ME functionality: +CMS ERROR: Write Command AT+CSCB=[,[,]] Parameters 0 Message types specified in and are accepted 1 Message types specified in and are not accepted. String type (string should be included in quotation marks); all different possible combinations of CBM message identifiers (refer ) (default is empty string); e.g. "0,1,5,320,922". Total 15 different values can be supported. values cannot be written consecutively, such as "100-200" String type(string should be included in quotation marks); all different possible combinations of CBM data coding schemes (refer ) (default is empty string); e.g. "0,5". Total 5 different values can be supported. values cannot be written consecutively, such as "0-5". Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 131 2015-08-03 Mode Max Response TimeReference 3GPP TS 27.005 Note AT+CSCB=0 will reset and and select no and no . AT+CSCB=1 means all are accepted but this command has no effect on the list of the accepted. "0-255" means all are accepted. AT+CSCB=0, will add the values in the current list handled by module. AT+CSCB=0, will add the values in the current list handled by module. If AT+CSCB=0, is received while the list of is full, OK is returned and new value is not added. 4.2.14 AT+CSDH Show SMS Text Mode Parameters AT+CSDH Show SMS Text Mode Parameters Response +CSDH: (list of supported s) OK Test Command AT+CSDH=? Parameter See Write Command Response +CSDH: OK Read Command AT+CSDH? Parameter See Write Command Response TA determines whether detailed header information is shown in text mode result codes. OK Write Command AT+CSDH=[] Parameter 0 Do not show header values defined in commands +CSCA and +CSMP (, , , , and ) nor , or in +CMT, +CMGL, +CMGR result codes for SMS-DELIVERs and SMS-SUBMITs in text mode 1 Show the values in result codes Parameter Saving Mode NO_SAVE Max Response - Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 132 2015-08-03 Time Reference 3GPP TS 27.005 Note 4.2.15 AT+CSMP Set SMS Text Mode Parameters AT+CSMP Set SMS Text Mode Parameters Response +CSMP: (list of supported s),(list of supported s),(list of supported s),(list of supported s) OK Test Command AT+CSMP=? Parameters See Write Command Response +CSMP: ,,, OK Read Command AT+CSMP? Parameters See Write Command Response TA selects values for additional parameters needed when SM is sent to the network or placed in a storage when text mode is selected (+CMGF=1). It is possible to set the validity period starting from when the SM is received by the SMSC ( is in range 0... 255) or define the absolute time of the validity period termination ( is a string). Note: The Command writes the parameters in NON-VOLATILE memory. OK Write Command AT+CSMP=[<fo[,,,< dcs>]] Parameters Depending on the command or result code: first octet of GSM 03.40 SMS-DELIVER, SMS-SUBMIT (default 17), SMS-STATUS-REPORT, or SMS-COMMAND (default 2) in integer format. SMS status report is supported under text mode if is set to 49. Depending on SMS-SUBMIT setting: GSM 03.40 TP-Validity-Period either in integer format (default 167) or in time-string format (refer) GSM 03.40 TP-Protocol-Identifier in integer format (default 0). GSM 03.38 SMS Data Coding Scheme in Integer format. Parameter Saving Mode NO_SAVE Max Response TimeSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 133 2015-08-03 Reference 3GPP TS 27.005 Note 4.2.16 AT+CSMS Select Message Service AT+CSMS Select Message Service Response +CSMS: (list of supported s) OK Test Command AT+CSMS=? Parameter See Write Command Response +CSMS: ,,, OK Read Command AT+CSMS? Parameters See Write Command Response +CSMS: ,, OK If error is related to ME functionality: +CME ERROR: Write Command AT+CSMS= Parameters 0 GSM 03.40 and 03.41 (the syntax of SMS AT commands is compatible with 3GPP TS 27.005 Phase 2 version 4.7.0; Phase 2+ features which do not require new Command syntax may be supported (e.g. correct routing of messages with new Phase 2+ data coding schemes)) 1 GSM 03.40 and 03.41 (the syntax of SMS AT commands is compatible with 3GPP TS 27.005 Phase 2+ version; the requirement of setting 1 is mentioned under corresponding command descriptions) Mobile Terminated Messages: 0 Type not supported 1 Type supported Mobile Originated Messages: 0 Type not supported 1 Type supported Broadcast Type Messages: 0 Type not supported 1 Type supported Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 134 2015-08-03 Max Response TimeReference 3GPP TS 27.005 Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 135 2015-08-03 5 AT Commands for SIM Application Toolkit 5.1 Overview Command Description AT+STKTRS This command is used to send STK terminal response AT+STKENVS This command is used to send STK envelope command AT+STKCALL Trigger STK call AT+STKSMS Trigger STK SMS AT+STKSS Trigger STK SS AT+STKUSSD Trigger STK USSD AT+STKDTMF Trigger STK DTMF +STKPCI This unsolicited result code is used to indicate proactive command Indication. AT+STKMENU Show STK main menu AT+STKPCIS Switch STK URC string 5.2 Detailed Descriptions of Commands 5.2.1 AT+STKTRS STK Terminal Response AT+STKTRS STK Terminal Response. Response +STKTRS: <result_length>,<text_length> OK Test Command AT+STKTRS=? Parameter See Write Command Response OK Read Command AT+STKTRS? Write Command AT+STKTRS=[,] Response OK ERROR Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 136 2015-08-03 Parameter HEX String --specified in GSM11.14[12.12]'00' = Command performed successfully;'10' = Proactive SIM session terminated by the user;'11' = Backward move in the proactive SIM session requested by the user; …'2000' = ME currently unable to process command, No specific cause can be given;'2001' = ME currently unable to process command, Screen is busy; … Hex String If response to GET INPUT or GET INKEY --specified in GSM11.14[12.15] -text string, the first 2 char is Data coding scheme If response to SELECT ITEM --specified in GSM11.134[12.10] -Identifier of item chosen Parameter Saving Mode NO_SAVE Max Response TimeReference Note For more detail used, can refer AT+STKTR command 5.2.2 AT+STKENVS STK Envelope Command AT+STKENVS STK Envelope Command Response +STKENVS: <command_length>,<data_length> OK Test Command AT+STKENVS=? Parameter See Write Command Response OK Read Command AT+STKENVS? Parameter See Write Command Write Command AT+STKENVS=< command>[,<data Response OK ERROR Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 137 2015-08-03] Parameter HEX String --specified in GSM11.14[13.1]'D3' = Menu Selection;'D6' =Event download; Hex String If command is ‘D3’ --specified in GSM11.14[8.2] -Item identifier of main menu If command is ‘D6’ --specified in GSM11.14[11] -event list'04' = User activity'05' = Idle screen available'07' = Language selection Parameter Saving Mode NO_SAVE Max Response TimeReference Note For more detail used, can refer AT+STKENV command 5.2.3 AT+STKCALL STK call setup AT+STKCALL STK call setup Response OK Test Command AT+STKCALL=? Parameter See Write Command Write Command AT+STKCALL=< command> Response OK ERROR Parameter stk call command 0 Trigger modem to send STK CALLSETUP 4 Trigger modem to send STK CALLSETUP but icon cannot be displayed 16 Proactive session terminated by user 18 No response from user 32 ME currently unable to process this command 34 User reject setup call 50 Command data not understood by ME Note: Above are the possible terminal response value needed to be responded by application. It’s modem’s responsibility to response for other terminal response value. Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 138 2015-08-03 Max Response Time - Reference Note According to spec 11.14, 0x12 ("No response from user") is not a possible terminal response value for STK CALLSETUP. So we will translate 0x12("No response from user") to 0x20 ("ME currently unable to process this command"). 5.2.4 AT+STKSMS STK SMS delivery AT+STKSMS STK SMS delivery Response OK Test Command AT+STKSMS=? Parameter See Write Command Write Command AT+STKSMS= Response OK ERROR Parameter stk sms command 0 Trigger modem to send STK SMS 4 Trigger modem to send STK SMS but icon cannot be displayed Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Above are the possible terminal response value needed to be responded by application. It’s modem’s responsibility to response for other terminal response value 5.2.5 AT+STKSS STK SS setup AT+STKSS STK SS setup Response OK Test Command AT+STKSS=? Parameter See Write Command Write Command AT+STKSS= Response OK ERROR Parameter stk ss command 0 Trigger modem to send STK SS 4 Trigger modem to send STK SS but icon cannot be Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 139 2015-08-03 displayed 50 Command data not understood by ME Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Above are the possible terminal response value needed to be responded by application. It’s modem’s responsibility to response for other terminal response value. 5.2.6 AT+STKUSSD STK USSD setup AT+STKUSSD STK USSD setup Response OK Test Command AT+STKUSSD=? Parameters See Write Command Response OK ERROR Write Command AT+STKUSSD= Parameters STK ss command 0 Trigger modem to send STK USSD 4 Trigger modem to send STK USSD but icon cannot be displayed 50 Command data not understood by ME Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Above are the possible terminal response value needed to be responded by application.It’s modem’s responsibility to response for other terminal response value. 5.2.7 AT+STKDTMF STK sending DTMF AT+STKDTMF STK sending DTMF Response OK Test Command AT+STKDTMF=? Parameters See Write Command Write Command AT+STKDTMF=< Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 140 2015-08-03 command> ERROR Parameters STK DTMF command 0 Trigger modem to send STK DTMF 4 Trigger modem to send STK DTMF but icon cannot be displayed 32 ME currently unable to process command Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Above are the possible terminal response value needed to be responded by application.It’s modem’s responsibility to response for other terminal response value. 5.2.8 +STKPCI STK Proactive Command Indication +STKPCI STK Proactive Command Indication +STKPCI: <pci_type>[,<proactive_command>,…] Parameter <pci_type> -0 The SAT command is handled by TE. -1 The SAT command is handled by ME. -2 No other command (end of session) -DISPLAY TEXT,, -GET INKEY, , -GET INPUT, ,,, -PLAY TONE,,,, -SET UP MENU,, -SELECT ITEM, , -ITEM,,, -SEND SHORT MESSAGE,,, -SEND SS,, -SEND USSD,, -SETUP CALL,, -SET UP IDLE MODE TEXT, -SEND DTMF,,. If = 0, the alpha id is null If = 0, the addr is null Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 141 2015-08-03 Max Response TimeReference Note For detail introduction, please refer to SIM800 Series_STK_Application Note.doc. 5.2.9 AT+STKMENU STK Main menu command AT+STKMENU STK Main menu command Response OK Test Command AT+STKMENU =? Parameters See Read Command Response [+STKMENU:,,] [+STKMENU:,,] [+STKMENU:,,] […] OK Read Command AT+STKMENU ? Parameters The menu’s index, begin 1 The item identifier The content of item, code by EFADN Parameter Saving Mode NO_SAVE Max Response TimeReference Note When stkpci is off, read command response will null. 5.2.10 AT+STKPCIS STK URC switch command AT+STKPCIS STK URC switch command Response +STKPCIS: (0-1) OK Test Command AT+STKPCIS=? Parameters See Write Command Read Command AT+STKPCIS? Response +STKPCIS: OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 142 2015-08-03 Parameters Response OK ERROR Write Command AT+STKPCIS=< switch> Parameters the switch of STK URC -0 The STK URC is off -1 The STK URC is ON Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 143 2015-08-03 6 AT Commands Special for SIMCom 6.1 Overview Command Description AT+SIDET Change the side tone gain level AT+CPOWD Power off AT+SPIC Times remained to input SIM PIN/PUK AT+CMIC Change the microphone gain level AT+CALA Set alarm time AT+CALD Delete alarm AT+CADC Read ADC AT+CSNS Single numbering scheme AT+CDSCB Reset cell broadcast AT+CMOD Configure alternating mode calls AT+CFGRI Indicate RI when using URC AT+CLTS Get local timestamp AT+CLDTMF Local DTMF tone generation AT+CDRIND CS voice/data call termination indication AT+CSPN Get service provider name from SIM AT+CCVM Get and set the voice mail number on the SIM AT+CBAND Get and set mobile operation band AT+CHF Configure hands free operation AT+CHFA Swap the audio channels AT+CSCLK Configure slow clock AT+CENG Switch on or off engineering mode AT+SCLASS0 Store class 0 SMS to SIM when received class 0 SMS AT+CCID Show ICCID AT+CMTE Set critical temperature operating mode or query temperature AT+CMGDA Delete all SMS AT+STTONE Play SIM toolkit tone AT+SIMTONE Generate specific tone AT+CCPD Enable or disable alpha string AT+CGID Get SIM card group identifier AT+MORING Show state of mobile originated call AT+CMGHEX Enable or disable sending non-ascii character SMS AT+CCODE Configure SMS code mode AT+CIURC Enable or disable initial URC presentation Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 144 2015-08-03 AT+CPSPWD Change PS super password AT+EXUNSOL Enable or disable proprietary unsolicited indications AT+CGMSCLASS Change GPRS multislot class AT+CDEVICE View current flash device type AT+CCALR Call ready query AT+GSV Display product identification information AT+SGPIO Control the GPIO AT+SPWM Generate the pulse-width-modulation AT+ECHO Echo cancellation control AT+CAAS Control auto audio switch AT+SVR Configure voice coding type for voice calls AT+GSMBUSY Reject incoming call AT+CEMNL Set the list of emergency number AT*CELLLOCK Set the list of ARFCN which needs to be locked AT+SLEDS Set the timer period of net light AT+CBUZZERRING Use the buzzer sound as the incoming call ring AT+CEXTERNTONE Close or open the microphone AT+CNETLIGHT Close the net light or open it to shining AT+CWHITELIST Set the white list AT+CSDT Switch on or off detecting SIM card AT+CSMINS SIM inserted status reporting AT+CSGS Netlight indication of GPRS status AT+CMICBIAS Close or open the MICBIAS AT+DTAM Set TTS and record play mode in call AT+SJDR Set jamming detection fuction AT+CPCMCFG Set PCM parameter AT+CPCMSYNC Set PCM sync parameter AT+CANT Antenna detecting AT+CAGCSET Close or open AGC function AT+SD2PCM SD and PCM switch function AT+SKPD Keypad detecting function AT+SIMTONEX Custom tones AT+CROAMING Roaming state AT+CNETSCAN Performing a net survey to show all the cells’ information AT+CMNRP Dual serial port feature AT+CEGPRS Switch on or off EDGE AT+CGPIO Control the GPIO by PIN index AT+CMEDPLAY Play audio file Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 145 2015-08-03 AT+CMEDIAVOL Control the volume when playing audio file AT+SNDLEVEL Set the sound level of special AT command AT+ECHARGE Charge control AT+SIMTIMER Modify the poll interval time requested by SIM card AT+SPE Speech enhancement control AT+CCONCINDEX Report concatenated SMS index AT+SDMODE SD and PCM switch function AT+SRSPT Control SMS retransmission 6.2 Detailed Descriptions of Commands 6.2.1 AT+SIDET Change the Side Tone Gain Level AT+SIDET Change the Side Tone Gain Level Response +SIDET: (list of supported s),(list of supported s) OK Test Command AT+SIDET=? Parameters See Write Command Response +SIDET: (,),…, (,) OK Read Command AT+SIDET? Parameters See Write Command Response OK ERROR Write Command AT+SIDET=, Parameters 0 Main audio channel 1 Aux audio channel 2 Main audio channel hand free mode 3 Aux audio channel hand free mode Int: 0-16 Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note value of read command is related to specific. Scope of parameter is different among SIM800 series Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 146 2015-08-03 project, please refer to chapter 21 for details. 6.2.2 AT+CPOWD Power off AT+CPOWD Power Off Response [NORMAL POWER DOWN] Write Command AT+CPOWD=<nParameter 0 Power off urgently (Will not send out NORMAL POWER DOWN) 1 Normal power off (Will send out NORMAL POWER DOWN) Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.3 AT+SPIC Times Remained to Input SIM PIN/PUK AT+SPIC Times Remained to Input SIM PIN/PUK Response Times remained to input SIM PIN +SPIC: ,,, OK Execution Command AT+SPIC Parameters Times remained to input chv1 Times remained to input chv2 Times remained to input puk1 Times remained to input puk2 Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.4 AT+CMIC Change the Microphone Gain Level AT+CMIC Change the Microphone Gain Level Test Command AT+CMIC=? Response +CMIC: (list of supported s),(list of supported s) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 147 2015-08-03 OK Parameters See Write Command Response +CMIC: (,),…,(,) OK Read Command AT+CMIC? Parameters See Write Command Response OK ERROR Write Command AT+CMIC=,<gainlevelParameters 0 Main audio channel 1 Aux audio channel 2 Main audio channel hand free mode 3 Aux audio channel hand free mode Int: 0 – 15 0 0dB 1 +1.5dB 2 +3.0 dB 3 +4.5 dB 4 +6.0 dB 5 +7.5 dB 6 +9.0 dB 7 +10.5 dB 8 +12.0 dB 9 +13.5 dB 10 +15.0 dB 11 +16.5 dB 12 +18.0 dB 13 +19.5 dB 14 +21.0 dB 15 +22.5 dB Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note value is related to specific. The default gain level of main audio channel is 10. Scope of parameter is different among SIM800 series Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 148 2015-08-03 project, please refer to chapter 21 for details. 6.2.5 AT+CALA Set Alarm Time AT+CALA Set Alarm Time Response +CALA: ("yy/mm/dd,hh:mm:ss","hh:mm:ss"),(1-5),(0-7) OK If error is related to ME functionality: +CME ERROR: Test Command AT+CALA=? Parameters See Write Command Response [+CALA: ,[,] [ +CALA: ,[,] …]] OK If error is related to ME functionality: +CME ERROR: Read Command AT+CALA? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Unsolicited Result Code Indicate expired alarm. ALARM RING +CALV: Write Command AT+CALA=[,[,]] Parameters A string parameter(string should be included in quotation marks) which indicates the time when alarm arrives. The format is "yy/MM/dd,hh:mm:ss" where characters indicate the last two digits of year, month, day, hour, minute, second. Index of the alarm (range 1 to 5 for now). "0", "1"---"7" String type value indicating day of week for the alarm in one of the following formats: "<1..7>[,<1..7>[…]]" – Set a recurrent alarm for one or more days in the week. The digits 1 to 7 correspond to the days in the week, Monday (1), …, Sunday (7). Example: The string "1,2,3,4,5" may be used to set an alarm for all weekdays. "0" – Set a recurrent alarm for all days in the week. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 149 2015-08-03 Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note If user sets recurr function, the string of should not enter "yy/MM/dd", for example: set Monday to Friday alarm at the time of 16PM of alarm 2. AT+CALA="16:00:00",2,1,2,3,4,5 6.2.6 AT+CALD Delete Alarm AT+CALD Delete Alarm Response +CALD: (list of supported s) OK Test Command AT+CALD=? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CALD= Parameters Integer type value indicating the index of the alarm; default vaule is manufacturer specific (range from 1 to 5 now). Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.7 AT+CADC Read ADC AT+CADC Read ADC Response +CADC: (list of supported s),(list of supported s) OK Test Command AT+CADC=? Parameters 1 Success 0 Fail Integer 0-2800 Read Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 150 2015-08-03 +CADC: , OK AT+CADC? Parameters See Test Command Parameter Saving Mode NO_SAVE Max Response Time 2s Reference Note 6.2.8 AT+CSNS Single Numbering Scheme AT+CSNS Single Numbering Scheme Response +CSNS: (list of supported s) OK Test Command AT+CSNS=? Parameters See Write Command Response +CSNS: OK Read Command AT+CSNS? Parameters See Write Command Response OK ERROR Write Command AT+CSNS= Parameters 0 Voice 2 Fax 4 Data Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 151 2015-08-03 6.2.9 AT+CDSCB Reset Cell Broadcast AT+CDSCB Reset Cell Broadcast Execution Command AT+CDSCB Response OK Parameter Saving Mode NO_SAVE Max Response TimeReference Note Please also refer to AT+CSCB. 6.2.10 AT+CMOD Configure Alternating Mode Calls AT+CMOD Configure Alternating Mode Calls Response +CMOD: (0) OK Test Command AT+CMOD=? Parameters See Write Command Response +CMOD: OK Read Command AT+CMOD? Parameters See Write Command Response OK ERROR Write Command AT+CMOD=[] Parameters 0 Only single mode is supported Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.11 AT+CFGRI Indicate RI When Using URC AT+CFGRI Indicate RI When Using URC Test Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 152 2015-08-03 +CFGRI: (0,1) OK AT+CFGRI=? Parameters See Write Command Response +CFGRI: OK Read Command AT+CFGRI? Parameters See Write Command Response OK ERROR Write Command AT+CFGRI= Parameters 0 Off 1 On(TCPIP,FTP and URC control RI PIN) 2 On(only TCPIP control RI PIN) Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note RI PIN can not controlled by "AT+CFGRI" command when module has call service or receiving SMS. 6.2.12 AT+CLTS Get Local Timestamp AT+CLTS Get Local Timestamp Test Command AT+CLTS=? Response +CLTS: "yy/MM/dd,hh:mm:ss+/-zz" OK Read Command AT+CLTS? Response +CLTS: OK Response OK ERROR Write Command AT+CLTS= Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 153 2015-08-03 0 Disable 1 Enable Unsolicited Result Code When "get local timestamp" function is enabled, the following URC may be reported if network sends the message to the MS to provide the MS with subscriber specific information.Refresh network name by network: *PSNWID: "", "", "", , "",Refresh time and time zone by network: This is UTC time, the time queried by AT+CCLK command is local time. *PSUTTZ: , , , , , , "",Refresh network time zone by network: +CTZV: ""Refresh Network Daylight Saving Time by network: DST: Parameters String type; mobile country code String type; mobile network code String type; name of the network in full length. Integer type; indicates whether to add CI. 0 The MS will not add the initial letters of the Country's Name to the text string. 1 The MS will add the initial letters of the Country's Name and a separator (e.g. a space) to the text string. String type; abbreviated name of the network Integer type; indicates whether to add CI. 0 The MS will not add the initial letters of the Country's Name to the text string. 1 The MS will add the initial letters of the Country's Name and a separator (e.g. a space) to the text string. 4 digits of year (from network) Month (from network) Day (from network) Hour (from network) Minute (from network) Second (from network) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 154 2015-08-03 String type; network time zone. If the network time zone has been adjusted for Daylight Saving Time, the network shall indicate this by including the (Network Daylight Saving Time) Network Daylight Saving Time; the content of this indicates the value that used to adjust the network time zone 0 No adjustment for Daylight Saving Time 1 +1 hour adjustment for Daylight Saving 2 +2 hours adjustment for Daylight Saving Time 3 Reserved Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note Support for this Command will be network dependent. Set AT+CLTS=1, it means user can receive network time updating and use AT+CCLK to show current time. 6.2.13 AT+CLDTMF Local DTMF Tone Generation AT+CLDTMF Local DTMF Tone Generation Test Command AT+CLDTMF=? Response +CLDTMF: (1-100),(0-9,A,B,C,D,E,F,,#),(10-500) OK Response OK ERROR Write Command AT+CLDTMF=< n>,[] Parameters A numeric parameter (1-100) which indicates the duration of all DTMF tones. <DTMF -string> A string parameter (string should be included in quotation marks) which has a max length of 20 chars of form , separated by commas. A single ASCII chars in the set 0-9, #,, A-D. In addition, E and F is supported too. E represents single frequency 1400HZ sound, F represents single frequency 2300HZ sound. timeBase to generate DTMF sound.the DTMF on time is *, DTMF off time is timeBase,the default value is 100ms. Execution Command AT+CLDTMF Response OK Abort any DTMF tone currently being generated and any DTMF tone sequence. Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 155 2015-08-03 Mode Max Response TimeReference Note Local DTMF tone can be played in call, play mode is controlled by AT+DTAM. 6.2.14 AT+CDRIND CS Voice/Data Call Termination Indication AT+CDRIND CS Voice/Data Call Termination Indication Response +CDRIND: (list of supported s) OK Test Command AT+CDRIND=? Parameter See Write Command Response +CDRIND: OK Read Command AT+CDRIND? Parameter See Write Command Response OK ERROR Parameter A numeric parameter to enable an unsolicited event code indicating whether a CS voice call, CS data has been terminated. 0 Disable 1 Enable Unsolicited result code When enabled, an unsolicited result code is returned after the connection has been terminated +CDRIND: Write Command AT+CDRIND=< n> Parameter Connection type 0 CSV connection 1 CSD connection 2 PPP connection Parameter Saving Mode NO_SAVE Max Response TimeSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 156 2015-08-03 Reference Note 6.2.15 AT+CSPN Get Service Provider Name from SIM AT+CSPN Get Service Provider Name from SIM Response +CSPN: , OK If error is related to ME functionality: +CME ERROR: Read Command AT+CSPN? Parameters String type(string should be included in quotation marks); service provider name on SIM 0 Not display PLMN. Already registered on PLMN 1 Display PLMN Parameter Saving Mode NO_SAVE Max Response TimeReference Note CME errors occur if SIM is not inserted. 6.2.16 AT+CCVM Get and Set the Voice Mail Number on the SIM AT+CCVM Get and Set the Voice Mail Number on the SIM Response +CCVM: maximum length of field , maximum length of field OK Test Command AT+CCVM=? Parameters See Write Command Response If voice mail number is not set: OK If voice mail number is set: +CCVM: [,] OK Read Command AT+CCVM? Parameters See Write Command Write Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 157 2015-08-03 OK ERROR If error is related to ME functionality: +CME ERROR: AT+CCVM=[,] Parameters String type,The voice mail number to write to the SIM String type,The alpha-string to write to the SIM Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note 6.2.17 AT+CBAND Get and Set Mobile Operation Band AT+CBAND Get and Set Mobile Operation Band Response +CBAND: (list of supported <op_band>s) OK Test Command AT+CBAND=? Parameter See Write Command Response +CBAND: <op_band>[,<ALL_BAND>] OK Read Command AT+CBAND? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CBAND= Parameter <op_band> A string parameter which indicate the operation band. And the following strings should be included in quotation marks. EGSM_MODE PGSM_MODE DCS_MODE GSM850_MODE PCS_MODE EGSM_DCS_MODE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 158 2015-08-03 GSM850_PCS_MODE EGSM_PCS_MODE ALL_BAND Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note Radio settings are stored in non-volatile memory. The value of parameter <op_band> is different among SIM800 series project, please refer to chapter 21 for details. 6.2.18 AT+CHF Configure Hands Free Operation AT+CHF Configure Hands Free Operation Response +CHF: (list of supported s),(list of supported s) OK Test Command AT+CHF=? Parameters See Write Command Response +CHF: , OK Read Command AT+CHF? Parameters See Write Command Response OK ERROR If error is related to ME functionality: +CME ERROR: Unsolicited Result Code +CHF: Write Command AT+CHF= [,] Parameters 0 Unsolicited result code disabled 1 Unsolicited result code enabled (non-volatile) 0 Main audio channel 1 Aux audio channel 2 Main audio channel hand free mode 3 Aux audio channel hand free mode 4 PCM channel Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 159 2015-08-03 Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note This command is related to the actual module, don’t support power off save. 6.2.19 AT+CHFA Swap the Audio Channels AT+CHFA Swap the Audio Channels Test Command AT+CHFA=? Response +CHFA: (0=NORMAL_AUDIO, 1=AUX_AUDIO, 2=HANDFREE_AUDIO, 3=AUX_HANDFREE_AUDIO, 4=PCM_AUDIO) OK Response +CHFA: OK Read Command AT+CHFA? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CHFA= Parameter 0 Main audio channel 1 Aux audio channel 2 Main audio channel hand free mode 3 Aux audio channel hand free mode 4 PCM channel Parameter Saving Mode NO_SAVE Max Response TimeReference Note This Command swaps the audio channels among different channels. Scope of parameter is different among SIM800 series project, please refer to chapter 21 for details. Main audio channel hand free mode is the same with main audio channel; aux audio channel hand free mode is the same with aux audio Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 160 2015-08-03 channel. Channel 2, 3 is virtual channel. 6.2.20 AT+CSCLK Configure Slow Clock AT+CSCLK Configure Slow Clock Response +CSCLK: (list of supported s) OK Test Command AT+CSCLK=? Parameter See Write Command Response +CSCLK: OK Read Command AT+CSCLK? Parameter See Write Command Response OK ERROR Write Command AT+CSCLK=<nParameter 0 Disable slow clock, module will not enter sleep mode. 1 Enable slow clock, it is controlled by DTR. When DTR is high, module can enter sleep mode. When DTR changes to low level, module can quit sleep mode. 2 Enable slow clock automatically. When there is no interrupt (on air and hardware such as GPIO interrupt or data in serial port), module can enter sleep mode. Otherwise, it will quit sleep mode. Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note There are two caveats when you want to quit sleep mode in mode 2: 1, You should input some characters (at least one) to awake module 2, An interval time of 100ms more is necessary between waking characters and following AT commands,otherwise the waking characters will not be discarded completely,and messy codes will be produced which may leads to UART baudrate re-adaptation. The +CSCLK value can not be reset by AT&F or ATZ command. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 161 2015-08-03 6.2.21 AT+CENG Switch on or off Engineering Mode AT+CENG Switch on or off Engineering Mode Response TA returns the list of supported modes. +CENG: (list of supported s),(list of supported s) OK Test Command AT+CENG=? Parameters See Write Command Read Command AT+CENG? Response Engineering Mode is designed to allow a field engineer to view and test the network information received by a handset, when the handset is either in idle mode or dedicated mode (that is: with a call active). In each mode, the engineer is able to view network interaction for the "serving cell" (the cell the handset is currently registered with) or for the neighboring cells. TA returns the current engineering mode. The network information including serving cell and neighboring cells are returned. carry with them corresponding network interaction. +CENG: , [+CENG: ,",,,,,,,, ,,[,,,,,,,<rxq_s ub>,<rxq_full>,<ch_mod>]"+CENG: ,",,[,,],,"…] OK if =3 +CENG: , [+CENG: ,,,,,,+CENG: ,,,,,,…] OK if =4 +CENG: , [+CENG: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 162 2015-08-03 ,",,,,,,,, ,,,,,,,,,,<rxq_s ub>,<rxq_full>,<ch_mod>"+CENG: ,",,,,,,,," …] OK Parameters See Write Command Response Switch on or off engineering mode. It will report +CENG: (network information) automatically if =2. OK ERROR Write Command AT+CENG=[,] Parameters 0 Switch off engineering mode 1 Switch on engineering mode 2 Switch on engineering mode, and activate the URC report of network information 3 Switch on engineering mode, with limited network information 4 Switch on engineering mode, with extern information 0 Un-display neighbor cell ID 1 Display neighbor cell ID If = 3, ignore this parameter. 0 The serving cell 1-6 The index of the neighboring cell Absolute radio frequency channel number, in decimal format ARFCN(Absolute radio frequency channel number) of BCCH carrier, in decimal format Receive level, in decimal format Receive quality, in decimal format Mobile country code, in decimal format Mobile network code, in decimal format Base station identity code, in decimal format Cell id, in hexadecimal format Location area code, in hexadecimal format Receive level access minimum, in decimal format Transmit power maximum CCCH, in decimal format Timing Advance, in decimal format Receiving level in dBm C1 value C2 value ARFCN of the TCH carrier, in decimal format Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 163 2015-08-03 Timeslot number MAIO value HSN value <rxq_sub> Receiving quality (sub), range is 0 - 7 <rxq_full> Receiving quality (full), range is 0 – 7 <ch_mod> Speech channel type, in string format Parameter Saving Mode NO_SAVE Max Response TimeReference Note and are in hex, <ch_mod> is string, and others are in DEC. If network supports frequency hopping, then is invalid, value is 0. Under non-dedicated mode: ,,,,<rxq_sub>,<rxq_full>,<ch_mod> parameters are invalid, shown in "x". Under dedicated mode, and in service cell are invalid, either all neighbor cell parameters. Parameter value of "AT+CSQ" is half of . The sum of and is 113. That is to say, = /2 and =113-. 6.2.22 AT+SCLASS0 Store Class 0 SMS to SIM When Received Class 0 SMS AT+SCLASS0 Store Class 0 SMS to SIM When Module Received Class 0 SMS Response +SCLASS0: (0, 1) OK Test Command AT+SCLASS0=? Parameters See Write Command Response +SCLASS0: OK Read Command AT+SCLASS0? Parameters See Write Command Response OK ERROR Write Command AT+SCLASS0=< mode> Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 164 2015-08-03 0 Disable to store Class 0 SMS to SIM when module receives Class 0 SMS 1 Enable to store Class 0 SMS to SIM when module receives Class 0 SMS Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.23 AT+CCID Show ICCID AT+CCID Show ICCID Test Command AT+CCID=? Response OK Execution Command AT+CCID Response Ccid data [ex. 898600810906F8048812] OK Parameter Saving Mode NO_SAVE Max Response Time 2s Reference Note 6.2.24 AT+CMTE Set Critical Temperature Operating Mode or Query Temperature AT+CMTE Set Critical Temperature Operating Mode or Query Temperature Response +CMTE: , OK Read Command AT+CMTE? Parameters See Write Command Response OK ERROR Write Command AT+CMTE= Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 165 2015-08-03 0 Disable temperature detection 1 Enable temperature detection range from -40.00 to 95.00 Parameter Saving Mode AT&W_SAVE Max Response Time 2s Reference Note When temperature is extremely high or low, product will power off. URCs indicating the alert level "1" or "-1" are intended to enable the user to take appropriate precautions, such as protecting the module from exposure to extreme conditions, or saving or backing up data etc. Level "2" or "-2" URCs are followed by immediate shutdown. 6.2.25 AT+CMGDA Delete All SMS AT+CMGDA Delete All SMS Response +CMGDA: (list of supported s) OK +CMS ERROR: Test Command AT+CMGDA=? Parameter See Write Command Response OK ERROR +CMS ERROR: Write Command AT+CMGDA= ParameterIf text mode: "DEL READ" Delete all read messages "DEL UNREAD" Delete all unread messages "DEL SENT" Delete all sent SMS "DEL UNSENT" Delete all unsent SMS "DEL INBOX" Delete all received SMS "DEL ALL" Delete all SMSIf PDU mode: 1 Delete all read messages 2 Delete all unread messages 3 Delete all sent SMS 4 Delete all unsent SMS 5 Delete all received SMS 6 Delete all SMS Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 166 2015-08-03 Parameter Saving Mode NO_SAVE Max Response Time 5s(delete 1 message) 25s(delete 50 messages) 25s(delete 150 messages) Reference Note 6.2.26 AT+STTONE Play SIM Toolkit Tone AT+STTONE Play SIM Toolkit Tone Response +STTONE: (list of supported s),(list of supported s),(list of supported s) OK If error is related to ME functionality: +CME ERROR: Test Command AT+STTONE=? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Unsolicited Result Code The playing is stopped or completed. +STTONE: 0 Write Command AT+STTONE=< mode>,,< duration> Parameters 0 Stop playing tone 1 Start playing tone Numeric type 1 Dial Tone 2 Called Subscriber Busy 3 Congestion 4 Radio Path Acknowledge 5 Radio Path Not Available / Call Dropped 6 Error / Special information 7 Call Waiting Tone 8 Ringing Tone 16 General Beep 17 Positive Acknowledgement Tone 18 Negative Acknowledgement or Error Tone Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 167 2015-08-03 19 Indian Dial Tone 20 American Dial Tone Numeric type, in milliseconds. Max requested value = 255601000 = 15300000ms (supported range = 10-15300000) Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.27 AT+SIMTONE Generate Specifically Tone AT+SIMTONE Generate Specifically Tone Response +SIMTONE: (0,1),(20-20000),(200-25500),(0,100-25500),(10-500000) OK Test Command AT+SIMTONE= ? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Unsolicited Result Code The playing is stopped or completed. +SIMTONE: 0 Write Command AT+SIMTONE= ,,<periodOn,[,< duration>] Parameters 0 Stop playing tone 1 Start playing tone The frequency of tone to be generated The period of generating tone, must be multiple of 100 The period of stopping tone, must be multiple of 100 Duration of tones in milliseconds Parameter Saving Mode NO_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 168 2015-08-03 6.2.28 AT+CCPD Enable or Disable Alpha String AT+CCPD Enable or Disable Alpha String Response +CCPD: (0,1) OK Test Command AT+CCPD=? Parameter See Write Command Response +CCPD: OK Read Command AT+CCPD? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CCPD= Parameter 0 Disable to present alpha string 1 Enable to present alpha string Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 6.2.29 AT+CGID Get SIM Card Group Identifier AT+CGID Get SIM Card Group Identifier Response +GID: , OK If error is related to ME functionality: +CME ERROR: Execution Command AT+CGID Parameters Integer type of SIM card group identifier 1 Integer type of SIM card group identifier 2 Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 169 2015-08-03 Mode Max Response TimeReference Note If the SIM supports GID files, the GID values will be retuned. Otherwise 0xff is retuned. 6.2.30 AT+MORING Show State of Mobile Originated Call AT+MORING Show State of Mobile Originated Call Response +MORING: (0,1) OK Test Command AT+MORING=? Parameter See Write Command Response +MORING: OK Read Command AT+MORING? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Parameter 0 Not show call state of mobile originated call 1 Show call state of mobile originated call. After the call number is dialed, the URC strings of MO RING will be sent if another call is alerted and the URC strings of MO CONNECTED will be sent if the call is established. Write Command AT+MORING=< mode> Unsolicited Result Code MO RING The call is alerted. MO CONNECTED The call is established. Parameter Saving Mode AT&W_SAVE Max Response TimeSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 170 2015-08-03 Reference Note 6.2.31 AT+CMGHEX Enable or Disable Sending Non-ASCII Character SMS AT+CMGHEX Enable or Disable Sending Non-ASCII Character SMS Response +CMGHEX: (list of supported s) OK Test Command AT+CMGHEX= ? Parameter See Write Command Response +CMGHEX: OK Read Command AT+CMGHEX? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CMGHEX= Parameter 0 Send SMS in ordinary way 1 Enable to send SMS varying from 0x00 to 0x7f except 0x1a and 0x1b under text mode and GSM character set Parameter Saving Mode NO_SAVE Max Response TimeReference Note Only be available in TEXT mode and AT+CSCS="GSM". 6.2.32 AT+CCODE Configure SMS Code Mode AT+CCODE Configure SMS Code Mode Response +CCODE: (0,1) OK Test Command AT+CCODE=? Parameter See Write Command Read Command AT+CCODE? Response +CCODE: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 171 2015-08-03 OK Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CCODE=< mode> Parameter 0 Code mode compatible with NOKIA 1 Code mode compatible with SIEMENS Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.33 AT+CIURC Enable or Disable Initial URC Presentation AT+CIURC Enable or Disable Initial URC Presentation Response +CIURC: (0,1) OK Test Command AT+CIURC=? Parameters See Write Command Response +CIURC: OK Read Command AT+CIURC? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CIURC= Parameters 0 Disable URC presentation. 1 Enable URC presentation Parameter Saving Mode AT&W_SAVE Max Response - Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 172 2015-08-03 Time Reference Note When module is powered on and initialization procedure is over. URC "Call Ready" will be presented if is 1. 6.2.34 AT+CPSPWD Change PS Super Password AT+CPSPWD Change PS Super Password Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CPSPWD=< oldpwd>, Parameters String type(string should be included in quotation marks). Old password and length should be 8. String type(string should be included in quotation marks). New password and length should be 8. Parameter Saving Mode NO_SAVE Max Response TimeReference Note Default value of is "12345678". If module is locked to a specific SIM card through AT+CLCK and password lost or SIM state is PH-SIM PUK, user can use the super password to unlock it. It is not supported temporarily. 6.2.35 AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications AT+EXUNSOL Enable or Disable Proprietary Unsolicited Indications Response +EXUNSOL: (list of supported s) OK Test Command AT+EXUNSOL= ? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+EXUNSOL= , Parameters String type(string should be included in quotation marks). values are currently reserved by the present document Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 173 2015-08-03 "SQ" Signal Quality Report Displays signal strength and channel bit error rate (similar to AT+CSQ) in form +CSQN: ,when values change. 0 Disable 1 Enable 2 Query Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 6.2.36 AT+CGMSCLASS Change GPRS Multislot Class AT+CGMSCLASS Change GPRS Multislot Class Response MULTISLOT CLASS: (2,4,8,9,10,12) OK Test Command AT+CGMSCLA SS=? Parameter See Write Command Response MULTISLOT CLASS: OK Read Command AT+CGMSCLA SS? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CGMSCLA SS= Parameter GPRS multi-slot class Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 174 2015-08-03 6.2.37 AT+CDEVICE View Current Flash Device Type AT+CDEVICE View Current Flash Device Type Read Command AT+CDEVICE? Response Device Name: Current flash device type OK Parameter Saving Mode NO_SAVE Max Response TimeReference V.25ter Note 6.2.38 AT+CCALR Call Ready Query AT+CCALR Call Ready Query Response +CCALR: (list of supported s) OK Test Command AT+CCALR=? Parameter A numeric parameter which indicates whether the module is ready for phone call. 0 Module is not ready for phone call 1 Module is ready for phone call Response ME returns the status of result code presentation and an integer which shows whether the module is currently ready for phone call. +CCALR: OK Read Command AT+CCALR? Parameter See Test Command Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.39 AT+GSV Display Product Identification Information AT+GSV Display Product Identification Information Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 175 2015-08-03 Execution Command AT+GSV Response TA returns product information text Example: SIMCOM_Ltd SIMCOM_SIM800H Revision: 1308B01SIM800H32 OK Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.40 AT+SGPIO Control the GPIO AT+SGPIO Control the GPIO Response +SGPIO: (0-1),(1-7),(0-1),(0-1) OK Test Command AT+SGPIO=? Parameters See Write Command Response OK ERROR Write Command AT+SGPIO=,, ,<levelParameters 0 Set the GPIO function including the GPIO output. 1 Read the GPIO level. Please note that only when the gpio is set as input, user can use parameter 1 to read the GPIO level, otherwise the module will return "ERROR". The GPIO you want to be set. (It has relations with the hardware, please refer to the hardware manual) Only when is set to 0, this option takes effect. 0 Set the GPIO to input. 1 Set the GPIO to output 0 Set the GPIO low level 1 Set the GPIO high level Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 176 2015-08-03 Max Response TimeReference Note Scope of parameter is different among SIM800 series project, please refer to chapter 21 for details. 6.2.41 AT+SPWM Generate the Pulse-Width-Modulation AT+SPWM Generate the Pulse-Width-Modulation Response +SPWM: (list of supported s),(list of supported s),(list of supported s) OK Test Command AT+SPWM=? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+SPWM=,, Parameters Integer type: the index number of PWM port, which value is 0-2; Current only support one channel,whether 0 or 1 or 2,the PWM port is the same. 0 For buzzer (according to the hardware support or not). 1 Corresponding to PWM_OUT0 in the hardware circuit 2 Corresponding to PWM_OUT1 in the hardware circuit The range of is 0-100000, the output frequency equals to CLK/(PWM_CNT+1),where PWM_CNT=CLK/ period-1. Duty ratio = PWM_THRES/( PWM_CNT+1) Parameter Saving Mode NO_SAVE Max Response Time - Reference Note The PWM clock source is 13MHz, the equation of the final frequency is: frequency = CLK/(PWM_CNT+1), where PWM_CNT = CLK/freq – 1. However, the equation can not be simplified. PWM_THRES should be less than the PWM_CNT. If freq euals 0, the output of PWM is in low state. 6.2.42 AT+ECHO Echo Cancellation Control AT+ECHO Echo Cancellation Control Test Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 177 2015-08-03 +ECHO: (0,1),(0-65535),(0-65535),(0-65535),(0-65535),(0,1) OK AT+ECHO=? Parameters See Write Command Response +ECHO: (,, ,, ),(,, ,, ) OK Read Command AT+ECHO? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+ECHO=,,,< nr>,[,<state] Parameters Audio channel 0 Main audio handset channel 1 Main audio handfree channel Nonlinear processing remove residual echo and background noise Acoustic echo cancellation Noise reduction Noise suppression Enable or disable to close echo algorithm 0 Echo algorithm be closed 1 Echo algorithm be actived Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note For this command, please refer to actual model. The default state the echo echo algorithm be actived, and the read command is not displayed. 6.2.43 AT+CAAS Control Auto Audio Switch AT+CAAS Control Auto Audio Switch Test Command AT+CAAS=? Response +CAAS: (0-2) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 178 2015-08-03 OK Parameter See Write Command Response +CAAS: OK Read Command AT+CAAS? Parameter See Write Command Response This parameter setting determines whether or not the audio channel will be switched automatically to the corresponding channel in case of headset attaching or detaching. OK If error is related to ME functionality: +CME ERROR: Write Command AT+CAAS= Parameter 0 Disable automatic audio channel switch function, the headset HOOK function is disabled; 1 Enable automatic audio channel switch function, the headset HOOK function is enabled; 2 Disable automatic audio channel switch function, the headset HOOK function is enabled. Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note For this command, please refer to actual model. The headset detection is still worked when is set to 0.6.2.44 AT+SVR Configure Voice Coding Type for Voice Calls AT+SVR Configure Voice Coding Type for Voice Calls Response +SVR: (list of supported <voice_rate_coding>s) OK Test Command AT+SVR=? Parameter See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 179 2015-08-03 Response +SVR: <voice_rate_coding> OK Read Command AT+SVR? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+SVR= Parameter <voice_rate_coding> A number parameter which indicate the voice coding type. 0 FR 1 EFR/FR 2 HR/FR 3 FR/HR 4 HR/EFR 5 EFR/HR 6 AMR-FR/EFR,AMR-HR 7 AMR-FR/EFR,AMR-HR/HR 8 AMR-HR/HR/AMR-FR/EFR 9 AMR-HR/AMR-FR/EFR 10 AMR-HR/AMR-FR/FR 11 AMR-HR/HR/AMR-FR 12 AMR-FR/AMR-HR 13 AMR-FR/FR/AMR-HR 14 AMR-FR/FR/AMR-HR/HR 15 AMR-FR/EFR/FR/AMR-HR/HR 16 AMR-HR/AMR-FR/EFR/FR/HR 17 AMR-FR/AMR-HR/EFR/FR/HR Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note The parameter of AT+SVR is stored in non-volatile memory. 6.2.45 AT+GSMBUSY Reject Incoming Call AT+GSMBUSY Reject Incoming Call Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 180 2015-08-03 Response +GSMBUSY: (0,1,2) OK Test Command AT+GSMBUSY= ? Parameter See Write Command Response +GSMBUSY: OK Read Command AT+GSMBUSY? Parameter See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+GSMBUSY= Parameter 0 Enable incoming call 1 Forbid all incoming calls 2 Forbid incoming voice calls but enable CSD calls Parameter Saving Mode NO_SAVE Max Response TimeReference Note The parameter is not saved if the module power down. 6.2.46 AT+CEMNL Set the List of Emergency Number AT+CEMNL Set the List of Emergency Number Response +CEMNL: (0-1),(1-11),("0"-"999")… OK Test Command AT+CEMNL=? Parameter See Write Command Response +CEMNL: [,,] OK Read Command AT+CEMNL? Parameter See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 181 2015-08-03 Response OK ERROR Write Command AT+CEMNL=< mode>[,<amount,] Parameter 0 Disable 1 Enable Amount of emergency number to be set. Up to 11 emergency numbers supportedEmergency numbers to be set by user which range is 0-999 Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note 6.2.47 ATCELLLOCK Set the List of ARFCN Which Needs to Be Locked ATCELLLOCK Set the List of ARFCN Which Needs to Be Locked Response CELLLOCK: (list of supported s)[,(list of supported s),(list of supported s)[, (list of supported s)[, (list of supported s)]]] OK Test Command ATCELLLOC K=? Parameter See Write Command Response CELLLOCK: [,,[,…]] OK Read Command ATCELLLOC K? Parameter See Write Command Response OK ERROR Write Command AT*CELLLOC K=[,,[,…]] Parameter 0 Disable 1 Enable Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 182 2015-08-03 Amount of arfcn to be set. Up to 3 arfcn supported. Arfcn needs to be locked by user. Scope: (0-124), (128-251), (512-885) or (975-1023). Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note 6.2.48 AT+SLEDS Set the Timer Period of Net Light AT+SLEDS Set the Timer Period of Net Light Response +SLEDS: (1-3),(0,40-65535),(0,40-65535) OK Test Command AT+SLEDS=? Parameters See Write Command Response +SLEDS: ,<timer_on>,<timer_off> OK Read Command AT+SLEDS? Parameters See Write Command Response OK ERROR Write Command AT+SLEDS=,<timer_on> ,<timer_off> Parameters 1 Set the timer period of net light while SIM800 series does not register to the network 2 Set the timer period net light while SIM800 series has already registered to the network 3 Set the timer period net light while SIM800 series is in the state of PPP communication <timer_on> Timer period of "LED ON" in decimal format which range is 0 or 40-65535(ms) <timer_off> Timer period of “LED OFF” in decimal format which range is 0 or 40-65535(ms) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 183 2015-08-03 Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note The default value is : ,<timer_on>,<timer_off> 1,64,800 2,64,3000 3,64,300 6.2.49 AT+CBUZZERRING Use the Buzzer Sound as the Incoming Call Ring AT+CBUZZERRING Use the Buzzer Sound as the Incoming Call Ring Response +CBUZZERRING: OK Read Command AT+CBUZZER RING? Parameter See Write Command Response OK ERROR Write Command AT+CBUZZER RING= Parameter 0 Disable the function of using buzzer sound as the incoming call ring 1 Enable the function of using buzzer sound as the incoming call ring Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note This buzzer function is depending on the hardware. 6.2.50 AT+CEXTERNTONE Close or Open the Microphone AT+CEXTERNTONE Close or Open the Microphone Response +CEXTERNTONE: (0,1) OK Test Command AT+CEXTERN TONE=? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 184 2015-08-03 Response +CEXTERNTONE: OK Read Command AT+CEXTERN TONE? Parameters See Write Command Response OK ERROR Write Command AT+CEXTERNT ONE= Parameters 0 Re-open the microphone 1 Close the microphone Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.51 AT+CNETLIGHT Close the Net Light or Open It to Shining AT+CNETLIGHT Close the Net Light or Open It to Shining Response +CNETLIGHT: (0,1) OK Test Command AT+CNETLIGH T=? Parameters See Write Command Response +CNETLIGHT: OK Read Command AT+CNETLIGH T? Parameters See Write Command Response OK ERROR Write Command AT+CNETLIGH T= Parameters 0 Close the net light 1 Open the net light to shining Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 185 2015-08-03 Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 6.2.52 AT+CWHITELIST Set the White List AT+CWHITELIST Set the White List Response +CWHITELIST: (0-3) OK Test Command AT+CWHITELI ST=? Parameter See Write Command Response +CWHITELIST: [,,,…] OK Read Command AT+CWHITELI ST? Parameters See Write Command Response OK ERROR Write Command AT+CWHITELI ST=[,,] Parameters 0 Disable 1 Enable only call white list 2 Enable only SMS white list 3 Enable call and SMS white list The index of phone number, scope: 1-30 Phone number to be set Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note Parameter mode value is 1, can save white list phone number ,Other mode value can not save white list phone number. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 186 2015-08-03 White list phone numbers are suitable to call and SMS function. 6.2.53 AT+CSDT Switch on or off Detecting SIM Card AT+CSDT Switch on or off Detecting SIM Card Response +CSDT: (0-1) OK Test Command AT+CSDT=? Parameters See Write Command Response +CSDT: OK Read Command AT+CSDT? Parameters See Write Command Response OK ERROR Write Command AT+CSDT= Parameters 0 Switch off detecting SIM card 1 Switch on detecting SIM card Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note User should select 8-pin SIM card holder to implement SIM card detection function. After plug out simcard, User should wait 2 seconds before plug in SIM card. 6.2.54 AT+CSMINS SIM Inserted Status Reporting AT+CSMINS SIM Inserted Status Reporting Response +CSMINS: (list of supported s) OK Test Command AT+CSMINS=? Parameter Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 187 2015-08-03 See Write Command Response +CSMINS: , OK Read Command AT+CSMINS? Parameters See Write Command Response OK ERROR If error is related to ME functionality: +CME ERROR: Unsolicited Result Code +CSMINS: , Write Command AT+CSMINS=< n> Parameters A numeric parameter to show an unsolicited event code indicating whether the SIM has been inserted or removed. 0 Disable 1 Enable A numeric parameter which indicates whether SIM card has been inserted. 0 Not inserted 1 Inserted Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 6.2.55 AT+CSGS Netlight Indication of GPRS Status AT+CSGS Netlight Indication of GPRS Status Response +CSGS: (0-2) OK Test Command AT+CSGS=? Parameters See Write Command Read Command AT+CSGS? Response +CSGS: OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 188 2015-08-03 Parameters See Write Command Response OK ERROR Write Command AT+CSGS= Parameters 0 Disable 1 Enable, the netlight will be forced to enter into 64ms on/300ms off blinking state in GPRS data transmission service. Otherwise, the netlight state is not restricted. 2 Enable, the netlight will blink according to AT+SLEDS in GPRS data transmission service. Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 6.2.56 AT+CMICBIAS Close or Open the MICBIAS AT+CMICBIAS Close or Open the MICBIAS Response +CMICBIAS: (0,1) OK Test Command AT+CMICBIAS =? Parameters See Write Command Response +CMICBIAS: OK Read Command AT+CMICBIAS ? Parameters See Write Command Response OK ERROR Write Command AT+CMICBIAS = Parameters 0 Turn off the micbias 1 Turn on the micbias Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 189 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeReference Note The settting take effect at the current channel only 6.2.57 AT+DTAM Set TTS and RECORD Play Mode in Call AT+DTAM Set TTS and RECORD Play Mode in Call Response +DTAM: (0-2) OK Test Command AT+DTAM=? Parameters See Write Command Response +DTAM: OK Read Command AT+DTAM? Parameters See Write Command Response OK ERROR Write Command AT+DTAM= Parameters TTS and record play mode 0 Local 1 Remote 2 Local and remote Parameter Saving Mode NO_SAVE Max Response TimeReference Note This command takes effect only in call. TTS and record not in call only play locally no matter what the mode is. Setting takes effect before TTS or record play. 6.2.58 AT+SJDR Set Jamming Detection Function AT+SJDR Set Jamming Detection Funcition Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 190 2015-08-03 Response +SJDR: (0,1) OK Test Command AT+SJDR=? Parameters See Write Command Response +SJDR: or +SJDR: ,,,, OK Read Command AT+SJDR? Parameters See Write Command Response OK ERROR If error is related to ME functionality: +CME ERROR: Unsolicited result codes supported: +SJDR: NO JAMMING or +SJDR: JAMMING DETECTED or +SJDR: INTERFERENCE DETECTED Write Command AT+SJDR= [,][,[,< display>]] Parameters 0 Disable jamming detection 1 Enable jamming detection 0 Should inquire status by reading command 1 Only report jamming status via URC from serial port 2 Only report jamming status via the PIN 3 Report jamming status via URC as well as the PIN The threshold to separate “+SJDR: JAMMING DETECTED” from “+SJDR: INTERFERENCE DETECTED” (while the signal strength variance is higher than , there could be industrial interferences , and “+SJDR: INTERFERENCE DETECTED” is reported). 1-255(default value:255) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 191 2015-08-03 0 Report jamming status via URC every 3000ms. (only when is set to “1” or “3”) 1 Report jamming status via URC when jamming status changed.(only when is set to “1” or “3”) Parameter Saving Mode NO_SAVE Max Response Time - Reference Note When you query jamming detection status after enable jamming detection mode, you will get the URC of the format below: +SJDR:1,,,, =0, means no jamming. =1, means jamming is detected. =2, means industrial interference is detected. “+SJDR: INTERFERENCE DETECTED” indicates industrial interference which signifies unintentional radio link disturbances by strong industrial radio sources. Jamming detection PIN is designed to indicate jamming by outputting different level. When jamming is detected, the PIN will output a high level, otherwise, it will output a low level. Jamming detection PIN is different among SIM800 series project, please refer to chapter 21 for details. 6.2.59 AT+CPCMCFG Set PCM Parameter AT+CPCMCFG Set PCM Parameter Response +CPCMCFG: (0-1) OK Test Command AT+CPCMCFG =? Parameters See Write Command Response +CPCMCFG: OK Read Command AT+CPCMCFG ? Parameters See Write Command Write Command AT+CPCMCFG = Response OK ERROR Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 192 2015-08-03 Parameters 0 MSB 1 LSB Parameter Saving Mode NO_SAVE Max Response TimeReference Note Part of the projects supported by this AT command, please refer to chapter 21 for details. 6.2.60 AT+CPCMSYNC Set PCM Sync Parameter AT+CPCMSYNC Set PCM Sync Parameter Response +CPCMSYNC: (0-1),(1-8) OK Test Command AT+CPCMSYN C=? Parameters See Write Command Response +CPCMSYNC: , OK Read Command AT+CPCMSYN C? Parameters See Write Command Response OK ERROR Write Command AT+CPCMSYN C=, Parameters 0 PCM short sync 1 PCM long sync 1-8 PCM sync length(1-8) Parameter Saving Mode NO_SAVE Max Response TimeReference Note The is only supported 1 when PCM sync is short sync. Part of the projects supported by this AT command, please refer to chapter 21 for details. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 193 2015-08-03 6.2.61 AT+CANT Antenna Detecting AT+CANT Antenna Detecting Response +CANT: (list of supported s),(list of supported s),(list of supported s) OK +CME ERROR: Test Command AT+CANT=? Parameters See Write Command Response +CANT: , , OK +CME ERROR: Read Command AT+CANT? Parameters See Write Command Response OK +CANT: Write Command AT+CANT=,<UrcEnable, Parameters 0 Disable the antenna detecting function 1 Enable the antenna detecting function 0 Disable reporting antenna state by URC 1 Enable reporting antenna state by URC 0-3600 Reporting timer in units of seconds, range: 0-3600. Set timer to 0 will close detect, the recommend value is 10. 0 Connected normally 1 Connected to GND 2 Connected to other power source 3 Not connected Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note Part of the projects supported by this AT command, please refer to chapter 21 for details. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 194 2015-08-03 6.2.62 AT+CAGCSET Close or Open AGC Function AT+CAGCSET Close or Open AGC Funcion Response +CAGCSET: (0,1) OK Test Command AT+CAGCSET= ? Parameters See Write Command Response +CAGCSET: OK Read Command AT+CAGCSET? Parameters See Write Command Response OK ERROR Write Command AT+CAGCSET= Parameters 0 Close AGC function 1 Open the AGC function Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.63 AT+SD2PCM SD and PCM Switch Function AT+SD2PCM SD and PCM Switch Function Response +SD2PCM: (0,1) OK Test Command AT+SD2PCM=? Parameters See Write Command Response +SD2PCM: OK Read Command AT+SD2PCM? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 195 2015-08-03 Response OK ERROR Write Command AT+SD2PCM=< mode> Parameters 0 SD card interface is valid 1 PCM interface is valid Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note: If user set from 1 to 0, user should execute at&w command to save this setting, and then reboot the module by AT command or pwrkey. Part of the projects supported by this AT command, please refer to chapter 21 for details. 6.2.64 AT+SKPD Keypad Detecting Function AT+SKPD Keypad Detecting Function Response +SKPD: (0-1) OK Test Command AT+SKPD=? Parameters See Write Command Response +SKPD: OK Read Command AT+SKPD? Parameters See Write Command Write Command AT+SKPD= Response OK ERROR If key has pressed or released, The URC report is: +SKPD: , Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 196 2015-08-03 Parameters 0 Disable Keypad detecting function 1 Enable Keypad detecting function The value of pressed or released keypad The status of keypad 0 Key released 1 Key pressed Parameter Saving ModeMax Response TimeReference Note Part of the projects supported by this AT command, please refer to chapter 21 for details. 6.2.65 AT+SIMTONEX Custom Tones AT+SIMTONEX Custom Tones Response +SIMTONEX: (0,1),(10-500000),(20-20000),(0-20000),(200-25500),(10-25500),(0-4)... OK Test Command AT+SIMTONEX =? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Unsolicited Result Code The playing is stopped or completed. +SIMTONEX: 0 Write Command AT+SIMTONEX =,,,,<periodOn,,< nextIndex>[,,,,,<nextIndex …] Parameters 0 Stop playing tone 1 Start playing tone Duration of tones in milliseconds The first frequency of tone to be generated The second frequency of tone to be generated The period of generating tone, must be multiple of 100 The period of stopping tone, must be multiple of 100 The index of next tone to play Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 197 2015-08-03 Mode Max Response TimeReference Note A group of parameters , , , , is used to define a tone. The index is defined from 0 to 4.AT+SIMTONEX supports up to five tone and the tones will play cyclically according the order specified by . For example, with "AT+SIMTONEX=1,10000,800,0,500,10,2,2000,0,500,100, 2600,0,500,10,1,1700,0,500,10,4,2200,0,600,100,0",the order is 800-> 2600->2000->1700->2200->800 and so on. This command support play in call, but the is limited to 10s. 6.2.66 AT+CROAMING Roaming State AT+CROAMING Roaming State Response +CROAMING: OK Execution Command AT+CROAMIN G Parameters 0 Home network 1 International network(different mcc) 2 Other network(different mnc but same operator) Parameter Saving Mode NO_SAVE Max Response TimeReference Note 6.2.67 AT+CNETSCAN Perform a Net Survey to Show All the Cells’ Information AT+CNETSCAN Perform a Net Survey to Show All the Cells’ Information Response +CNETSCAN: (list of supported s) OK Test Command AT+CNETSCA N=? Parameters See Write Command Read Command AT+CNETSCA N? Response +CNETSCAN: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 198 2015-08-03 OK Parameters See Write Command Response OK Write Command AT+CNETSCA N= Parameters 0 Hide lac and bsic information 1 Show lac and bsic information Response If format’s value is 0: Operator:"<Network_Operator_name>",MCC:,MNC: ,Rxlev:,Cellid:,Arfcn:[Operator: "<Network_Operator_name2>",MCC:,MNC:,Rxlev :,Cellid:,Arfcn:[…]] If format’s value is 1: Operator:"<Network_Operator_name>",MCC:,MNC: ,Rxlev:,Cellid:,Arfcn:,Lac:,Bsic:<Bsic[Operator:"<Network_Operator_name2>",MCC:<MCC2 ,MNC:,Rxlev:,Cellid:,Arfcn:,L ac:,Bsic:[…]] OK Execution Command AT+CNETSCA N Parameters <Network_Operator_name> Long format alphanumeric of network operator. Mobile country code. Mobile network code. Recieve level, in decimal format. Cell identifier, in hexadecimal format. Absolute radio frequency channel number, in decimal format. Location area code, in hexadecimal format. Base station identity code, in hexadecimal format. Parameter Saving Mode NO_SAVE Max Response Time 45s Reference Note 6.2.68 AT+CMNRP Dual Serial Port Feature AT+CMNRP Dual Serial Port Feature Test Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 199 2015-08-03 +CMNRP: (0-1) OK AT+CMNRP=? Parameters See Write Command Response +CMNRP: OK Read Command AT+CMNRP? Parameters See Write Command Response OK ERROR Write Command AT+CMNRP=< mode> Parameters 0 Disable dual serial port 1 Enable dual serial port Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note Please refer to SIM800 Series_Serial Port_Application Note.doc. Part of the projects supported by this AT command, please refer to chapter 21 for details. 6.2.69 AT+CEGPRS Switch on or off EDGE AT+CEGPRS Switch on or off EDGE Response +CEGPRS: (0,1) , (2,4,8,9,10,12) OK Test Command AT+CEGPRS=? Parameters See Write Command Response +CEGPRS: [,] OK Read Command AT+CEGPRS? Parameters See Write Command Write Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 200 2015-08-03 OK If error is related to ME functionality: +CME ERROR: AT+CEGPRS=< switch>[,] Parameters 0 Switch off EDGE 1 Switch on EDGE EGPRS multi-slot class Note: If value is equal to 1, must be input.otherwise is optional. Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note The module must restart if the EDGE is switched on or off. 6.2.70 AT+CGPIO Control the GPIO by PIN Index AT+CGPIO Control the GPIO by PIN Index Response +CGPIO: (0-1),( list of supported s),(0-1),(0-1) OK Test Command AT+CGPIO=? Parameters See Write Command Response OK ERROR Write Command AT+CGPIO=,,, Parameters 0 Set the GPIO function including the GPIO output . 1 Read the GPIO level. Please note that only when the gpio is set as input, user can use parameter 1 to read the GPIO level, otherwise the module will return "ERROR". The PIN index you want to be set. (It has relations with the hardware, please refer to the hardware manual) Only when is set to 0, this option takes effect. 0 Set the GPIO to input. 1 Set the GPIO to output 0 Set the GPIO low level 1 Set the GPIO high level Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 201 2015-08-03 Reference Note 6.2.71 AT+CMEDPLAY Play Audio File AT+CMEDPLAY Play Audio File Response +CMEDPLAY: (0-3) OK Test Command AT+CMEDPLA Y=? Parameters See Write Command Response +CMEDPLAY: OK Read Command AT+CMEDPLA Y? Parameters See Write Command Response if=0,2,3, response: OK if=1, start playing AT+CMEDPLAY=1,,, OK If error is related to MS functionality, response: +CME ERROR: Parameters command operation mode 0 Stop playing 1 Start playing 2 Pause playing 3 Resume playing Audio file path and name Audio play channel 0 Main channel 1 Aux channel Audio play volume,0-100 Audio playing state 0 Idle 1 Playing 2 Paused Write Command AT+CMEDPLA Y= Unsolicited result code Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 202 2015-08-03 +CMEDPLAY: 0 // play over Parameter Saving Mode NO_SAVE Max Response Time Reference Note 2 and 3 are not supported when playing audio file during call. The audio file can not be played duirng incoming call or outgoing call. Only support WAV, PCM, AMR and MP3 format. Only support WAV format with 8K 16bit during call. 6.2.72 AT+CMEDIAVOL Control the Volume when Playing Audio File AT+CMEDIAVOL Control the Volume when Playing Audio File Response +CMEDIAVOL: (0-100)OK Test Command AT+CMEDIAVO L=? Parameters See Write Command Response OK ERROR Write Command AT+CMEDIAVO L= Parameters 0-100 Integer type value with manufacturer specific range (smallest value represents the lowest sound level). Reference Note The command takes effect only when playing audio file. 6.2.73 AT+SNDLEVEL Set the Sound Level of Special AT Command AT+SNDLEVEL Set the Sound Level of Special AT Command Response +SNDLEVEL: (0-1),(0-100)OK Test Command AT+SNDLEVEL= ? Parameters See Write Command Read Command AT+SNDLEVEL? Response +SNDLEVEL:(0,),(1,) OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 203 2015-08-03 Parameters See Write Command Response OK ERROR Write Command AT+SNDLEVEL= , Parameters 0 adjust the sound level of STTONE and SIMTONE 1 adjust the sound level of CLDTMF 0-100 Integer type value with manufacturer specific range (smallest value represents the lowest sound level). Reference Note 6.2.74 AT+ECHARGE Charge Control AT+ECHARGE Charge Control Response +ECHARGE: (0-1) OK Test Command AT+ECHARGE= ? Parameters See Write Command Response +ECHARGE: OK Read Command AT+ECHARGE? Parameters See Write Command Response OK ERROR Write Command AT+ECHARGE= Parameters 0 Disable charge 1 Enable charge Parameter Saving Mode AT&W_SAVE Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 204 2015-08-03 6.2.75 AT+SIMTIMER Modify the Poll Interval Time Requested by SIM Card AT+SIMTIMER Modify the Poll Interval Time Requested by SIM Card Response +SIMTIMER: (1-26) OK Test Command AT+SIMTIMER =? Parameters See Write Command Response +SIMTIMER: OK Read Command AT+SIMTIMER ? Parameters See Write Command Response OK ERROR Write Command AT+SIMTIMER = Parameters 1-26 second Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 6.2.76 AT+SPE Speech Enhancement Control AT+SPE Speech Enhancement Control Response +SPE: (0,1) OK Test Command AT+SPE=? Parameters See Write Command Response +SPE: OK Read Command AT+SPE? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 205 2015-08-03 Response OK ERROR Write Command AT+SPE= Parameters 0 Disable Speech Enhancement 1 Enable Speech Enhancement Reference Note 6.2.77 AT+CCONCINDEX Report Concatenated SMS Index AT+CCONCINDEX Report Concatenated SMS Index Test Command AT+CCONCIND EX=? Response OK Execution Command AT+CCONCIND EX Response +CCONCINDEX: N,i,j,k,... OK where N is the number of segments that form the whole concatenated SMS i,j,k are the SMS indexes of each SMS segment , 0 if segment has not been received. If no concatenated SMS is present on the SIM or ME, only OK result code will be returned. Parameter Saving Mode NO_SAVE Reference Note 6.2.78 AT+SDMODE SD Mode Switch Function AT+SDMODE SD and PCM Switch Function Response +SDMODE: (0-1) OK Test Command AT+SDMODE=? Parameters See Write Command Read Command AT+SDMODE? Response +SDMODE: OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 206 2015-08-03 Parameters See Write Command Response OK ERROR Write Command AT+SDMODE=< mode> Parameters 0 SD card function is invalid 1 SD card function is valid Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note: If user set from 0 to 1, user should execute "AT&W" command to save this setting, and then reboot the module by AT command or pwrkey. Part of the project supported by this AT command, please refer to chapter 21 for details. 6.2.79 AT+SRSPT Control SMS Retransmission AT+SRSPT Control SMS Retransmission ResponseSRSPT: (0,1) OK Test Command AT+SRSPT=? Parameters See Write Command ResponseSRSPT: OK Read Command AT+SRSPT? Parameters See Write Command Response OK ERROR Write Command AT+SRSPT= Parameters0 Enable SMS retransmission 1 Disable SMS retransmission Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 207 2015-08-03 Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 208 2015-08-03 7 AT Commands for GPRS Support 7.1 Overview of AT Commands for GPRS Support Command Description AT+CGATT Attach or detach from GPRS service AT+CGDCONT Define PDP context AT+CGQMIN Quality of service profile (minimum acceptable) AT+CGQREQ Quality of service profile (requested) AT+CGACT PDP context activate or deactivate AT+CGDATA Enter data state AT+CGPADDR Show PDP address AT+CGCLASS GPRS mobile station class AT+CGEREP Control unsolicited GPRS event reporting AT+CGREG Network registration status AT+CGSMS Select service for MO SMS messages 7.2 Detailed Descriptions of AT Commands for GPRS Support 7.2.1 AT+CGATT Attach or Detach from GPRS Service AT+CGATT Attach or Detach from GPRS Service Response +CGATT: (list of supported s) OK Test Command AT+CGATT=? Parameters See Write Command Response +CGATT: OK Read Command AT+CGATT? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CGATT= Parameters Indicates the state of GPRS attachment Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 209 2015-08-03 0 Detached 1 Attached Other values are reserved and will result in an ERROR response to the Write Command. Parameter Saving Mode NO_SAVE Max Response Time 10 seconds Reference Note 7.2.2 AT+CGDCONT Define PDP Context AT+CGDCONT Define PDP Context Response +CGDCONT: (range of supported s),<PDP_type>,,,(list of supported<d_comp>s),(list of supported<h_comp>s) [+CGDCONT: (range of supported s), <PDP_type>,,,(list ofsupported <d_comp>s),(list of supported <h_comp>s)[...]] OK Test Command AT+CGDCONT =? Parameters See Write Command Response +CGDCONT: ,<PDP_type>,,<PDP_addr>,<data_comp>,<head_comp> [+CGDCONT: ,<PDP_type>,,<PDP_addr>,<data_comp>,<head_comp> […]] OK Read Command AT+CGDCONT ? Parameters See Write Command Response OK ERROR Write Command AT+CGDCONT =[,<PDP_ty pe>[,APN>[,[,<d_co mp>[,<h_comp>] ]]]] Parameters (PDP Context Identifier) a numeric parameter which specifies a particular PDP context definition. The parameter is local to the TE-MT interface and is used in other PDP context-related commands. The range of permitted values (minimum value=1) is returned by the test form of the Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 210 2015-08-03 command. <PDP_type> (Packet Data Protocol type) IP Internet Protocol (IETF STD 5) (Access Point Name) A string parameter (string should be included in quotation marks) which is a logical name that is used to select the GGSN or the external packet data network. If the value is null or omitted, then the subscription value will be requested.The default value is NULL. <PDP_addr> A string parameter (IP address). Format: "..." where =0..255 If the value is null or equals 0.0.0.0 a dynamic address will be requested. The allocated address may be read using the +CGPADDR command <d_comp> A numeric parameter that controls PDP data compression 0 –PDP data compression off (default if value is omitted) <h_comp> A numeric parameter that controls PDP data compression 0 –PDP header compression off (default if value is omitted) Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note7.2.3 AT+CGQMIN Quality of Service Profile (Minimum Acceptable) AT+CGQMIN Quality of Service Profile (Minimum Acceptable) Response +CGQMIN: <PDP_type>,(list of supported s),(list of supported s),(list of supported s),(list of supported s),(list of supported s) [+CGQMIN: <PDP_type>,(list of supported s),(list of supported s),(list of supported s),(list of supported s),(list of supported s) […]] OK Test Command AT+CGQMIN=? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 211 2015-08-03 Response +CGQMIN: ,,,>reliability>,, [+CGQMIN: ,,,,, […]] OK Read Command AT+CGQMIN? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CGQMIN=< cid>[,[,[,[, [,]]]]] Parameters 1..3 A numeric parameter which specifies a particular PDP context definition (see +CGDCONT command) 0 QOS precedence class subscribed value 1..3 QOS precedence class 0 QOS delay class subscribed value 1..4 QOS delay class subscribed 0 QOS reliability class subscribed value 1..5 QOS reliability class. 0 QOS peak throughput class subscribed value 1..9 QOS peak throughput class 0 QOS mean throughput class subscribed value 1..18 QOS mean throughput class 31 QOS mean throughput class best effort Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note 7.2.4 AT+CGQREQ Quality of Service Profile (Requested) AT+CGQREQ Quality of Service Profile (Requested) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 212 2015-08-03 Response +CGQREQ: <PDP_type>,(list of supported s),(list of supported s),(list of supported s),<list of supported s),(list of supported s) [+CGQREQ: <PDP_type>,(list of supported s),(list of supported s),(list of supported s),(list of supported s),(list of supported s) […]] OK Test Command AT+CGQREQ=? Parameters See Write Command Response +CGQREQ: ,,,>reliability>,, [+CGQREQ: ,,,,, […]] OK Read Command AT+CGQREQ? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CGQREQ=c id>[,<precedence[,[,[,[ ,]]]]] Parameters A numeric parameter which specifies a particular PDP context definition (see +CGDCONT Command) The following parameter are defined in GSM 03.60 A numeric parameter which specifies the precedence class 0 QOS precedence class subscribed value 1..3 QOS precedence class A numeric parameter which specifies the delay class 0 QOS delay class subscribed value 1..4 QOS delay class A numeric parameter which specifies the reliability class 0 QOS reliability class subscribed value 1..5 QOS reliability class; default value: 3 A numeric parameter which specifies the peak throughput class 0 QOS peak throughput class subscribed value 1..9 QOS peak throughput class Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 213 2015-08-03 A numeric parameter which specifies the mean throughput class 0 QOS mean throughput class subscribed value 1..18 QOS mean throughput class 31 QOS mean throughput class best effort Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note 7.2.5 AT+CGACT PDP Context Activate or Deactivate AT+CGACT PDP Context Activate or Deactivate Response +CGACT: (list of supported s) OK Test Command AT+CGACT=? Parameters See Write Command Response +CGACT: ,[+CGACT:,…] OK Read Command AT+CGACT? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CGACT=[,] Parameters Indicates the state of PDP context activation 0 Deactivated 1 Activated Other values are reserved and will result in an ERROR response to the Write Command. A numeric parameter which specifies a particular PDP context definition (see +CGDCONT Command). If the is omitted, it only affects the first cid. Parameter Saving Mode NO_SAVE Max Response 150 seconds Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 214 2015-08-03 Time Reference Note This command is used to test PDPs with network simulators. Successful activation of PDP on real network is not guaranteed. Refer to AT+CGDATA clarification for more information. 7.2.6 AT+CGDATA Enter Data State AT+CGDATA Enter Data State Test Command AT+CGDATA=? Response +CGDATA: list of supported s OK Parameter See Write Command Response CONNECT If error is related to ME functionality: +CME ERROR: Write Command AT+CGDATA=< L2P>[,] Parameters A string parameter (string should be included in quotation marks) that indicates the layer 2 protocol to be used between the TE and MT: "PPP" Point to Point protocol for a PDP such as IP Other values are not supported and will result in an ERROR response to the execution Command. A numeric parameter which specifies a particular PDP context definition (see +CGDCONT Command) Parameter Saving Mode NO_SAVE Max Response TimeReference Note 7.2.7 AT+CGPADDR Show PDP Address AT+CGPADDR Show PDP Address Response +CGPADDR: (list of defined s) OK Test Command AT+CGPADDR= ? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 215 2015-08-03 Response +CGPADDR: ,<PDP_addr> [+CGPADDR: ,<PDP_addr>[…]] OK ERROR Write Command AT+CGPADDR= Parameters A numeric parameter which specifies a particular PDP context definition (see +CGDCONT Command) <PDP_addr> String type, IP address Format: "..." where =0..255 Parameter Saving Mode NO_SAVE Max Response TimeReference Note Write command returns address provided by the network if a connection has been established. 7.2.8 AT+CGCLASS GPRS Mobile Station Class AT+CGCLASS GPRS Mobile Station Class Response +CGCLASS: (list of supported s) OK Test Command AT+CGCLASS= ? Parameter See Write Command Response +CGCLASS: OK Read Command AT+CGCLASS? Parameter See Write Command Response OK ERROR If error is related to ME functionality: +CME ERROR: Write Command AT+CGCLASS= Parameter A string parameter(string should be included in quotation marks) which indicates the GPRS mobile class (in Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 216 2015-08-03 descending order of functionality) B Class-B mode of operation (A/Gb mode), (not applicable in Iu mode) MT would operate PS and CS services but not simultaneously CG Class C in GPRS only mode CC Class C in circuit switched only mode (lowest) Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note It only supports Class B, CG and CC. 7.2.9 AT+CGEREP Control Unsolicited GPRS Event Reporting AT+CGEREP Control Unsolicited GPRS Event Reporting Response +CGEREP: (list of supported s) OK Test Command AT+CGEREP=? Parameters See Write Command Response +CGEREP: OK Read Command AT+CGEREP? Parameters See Write Command Response OK ERROR Write Command AT+CGEREP=< mode> Parameters 0 Disable event reporting. 1 Enable event reporting. Unsolicited Result Codes supported: +CGEV: NW DEACT <PDP_type>,<PDP_addr>[,] +CGEV: ME DEACT <PDP_type>,<PDP_addr>[,] +CGEV: NW DETACH +CGEV: ME DETACH Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 217 2015-08-03 Parameters <PDP_type> Packet Data Protocol type (see +CGDCONT Command) <PDP_addr> Packet Data Protocol address (see +CGDCONT Command) Context Id (see +CGDCONT Command) Parameter Saving Mode NO_SAVE Max Response TimeReference Note 7.2.10 AT+CGREG Network Registration Status AT+CGREG Network Registration Status Response +CGREG: (list of supported s) OK Test Command AT+CGREG=? Parameters See Write Command Response +CGREG: ,[,,] OK If error is related to ME functionality: +CME ERROR: Read Command AT+CGREG? Parameters See Write Command Response OK ERROR Write Command AT+CGREG=[< n>] Parameters 0 Disable network registration unsolicited result code 1 Enable network registration unsolicited result code +CGREG: 2 Enable network registration and location information unsolicited result code +CGREG: [,,] 0 Not registered, MT is not currently searching an operator to register to.The GPRS service is disabled, the UE is allowed to attach for GPRS if requested by the user. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 218 2015-08-03 1 Registered, home network. 2 Not registered, but MT is currently trying to attach or searching an operator to register to. The GPRS service is enabled, but an allowable PLMN is currently not available. The UE will start a GPRS attach as soon as an allowable PLMN is available. 3 Registration denied, The GPRS service is disabled, the UE is not allowed to attach for GPRS if it is requested by the user. 4 Unknown 5 Registered, roaming String type (string should be included in quotation marks); two byte location area code in hexadecimal format (e.g. "00C3" equals 195 in decimal) String type (string should be included in quotation marks); two bytes cell ID in hexadecimal format Parameter Saving Mode AT&W_SAVE Max Response TimeReference Note 7.2.11 AT+CGSMS Select Service for MO SMS Messages AT+CGSMS Select Service for MO SMS Messages Response +CGSMS: (list of currently available s) OK Test Command AT+CGSMS=? Parameters See Write Command Response +CGSMS: OK Read Command AT+CGSMS? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CGSMS= Parameters A numeric parameter which indicates the service or service preference to be used Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 219 2015-08-03 0 Packet Domain 1 Circuit switched 2 Packet Domain preferred (use circuit switched if GPRS not available) 3 Circuit switched preferred (use Packet Domain if circuit switched not available) Parameter Saving Mode AUTO_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 220 2015-08-03 8 AT Commands for TCPIP Application Toolkit 8.1 Overview Command Description AT+CIPMUX Start up multi-IP connection AT+CIPSTART Start up TCP or UDP connection AT+CIPSEND Send data through TCP or UDP connection AT+CIPQSEND Select data transmitting mode AT+CIPACK Query previous connection data transmitting state AT+CIPCLOSE Close TCP or UDP connection AT+CIPSHUT Deactivate GPRS PDP context AT+CLPORT Set local port AT+CSTT Start task and set APN, user name, password AT+CIICR Bring up wireless connection with GPRS or CSD AT+CIFSR Get local IP address AT+CIPSTATUS Query current connection status AT+CDNSCFG Configure domain name server AT+CDNSGIP Query the IP address of given domain name AT+CIPHEAD Add an IP head at the beginning of a package received AT+CIPATS Set auto sending timer AT+CIPSPRT Set prompt of ‘>’ when module sends data AT+CIPSERVER Configure module as server AT+CIPCSGP Set CSD or GPRS for connection mode AT+CIPSRIP Show remote IP address and port when received data AT+CIPDPDP Set whether to check state of GPRS network timing AT+CIPMODE Select TCPIP application mode AT+CIPCCFG Configure transparent transfer mode AT+CIPSHOWTP Display transfer protocol in IP head when received data AT+CIPUDPMODE UDP extended mode AT+CIPRXGET Get data from network manually AT+CIPSCONT Save TCPIP application context AT+CIPRDTIMER Set remote delay timer AT+CIPSGTXT Select GPRS PDP context AT+CIPTKA Set TCP keepalive parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 221 2015-08-03 8.2 Detailed Descriptions of Commands 8.2.1 AT+CIPMUX Start Up Multi-IP Connection AT+CIPMUX Start Up Multi-IP Connection Response +CIPMUX: (0,1) OK Test Command AT+CIPMUX=? Parameters See Write Command Response +CIPMUX: OK Read Command AT+CIPMUX? Parameters See Write Command Response OK Write Command AT+CIPMUX=< n> Parameters 0 Single IP connection 1 Multi IP connection Parameter Saving Mode NO_SAVE Max Response TimeReference Note Only in IP initial state, AT+CIPMUX=1 is effective; Only when multi IP connection and GPRS application are both shut down, AT+CIPMUX=0 is effective. 8.2.2 AT+CIPSTART Start Up TCP or UDP Connection AT+CIPSTART Start Up TCP or UDP Connection Test Command AT+CIPSTART= ? ResponseIf AT+CIPMUX=0 +CIPSTART: (list of supported ),(),() +CIPSTART: (list of supported ),(),() OKIf AT+CIPMUX=1 +CIPSTART: (list of supported ),(list of supported ),(),() +CIPSTART: (list of supported ),(list of supported ),(<domain Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 222 2015-08-03 name>),() OK Parameters See Write Command Response 1)If single IP connection (+CIPMUX=0) If format is right response OK otherwise response If error is related to ME functionality: +CME ERROR Response when connection exists ALREADY CONNECT Response when connection is successful CONNECT OK Otherwise STATE: CONNECT FAIL 2)If multi-IP connection (+CIPMUX=1) If format is right OK, otherwise response If error is related to ME functionality: +CME ERROR Response when connection exists ,ALREADY CONNECT If connection is successful ,CONNECT OK Otherwise ,CONNECT FAIL Write Command 1)If single IP connection (+CIPMUX=0) AT+CIPSTART= ,, Or AT+CIPSTART= ,, 2)If multi-IP connection (+CIPMUX=1) AT+CIPSTART= ,,, AT+CIPSTART= ,,,Parameters 0..5 A numeric parameter which indicates the connection number A string parameter which indicates the connection type "TCP" Establish a TCP connection "UDP" Establish a UDP connection A string parameter which indicates remote server IP address Remote server port A string parameter which indicates remote server domain name A string parameter which indicates the progress of connecting Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 223 2015-08-03 0 IP INITIAL 1 IP START 2 IP CONFIG 3 IP GPRSACT 4 IP STATUS 5 TCP CONNECTING/UDP CONNECTING/ SERVER LISTENING 6 CONNECT OK 7 TCP CLOSING/UDP CLOSING 8 TCP CLOSED/UDP CLOSED 9 PDP DEACT In Multi-IP state: 0 IP INITIAL 1 IP START 2 IP CONFIG 3 IP GPRSACT 4 IP STATUS 5 IP PROCESSING 9 PDP DEACT Parameter Saving Mode NO_SAVE Max Response Time When mode is multi-IP state, the max response time75 seconds. When mode is single state, and the state is IP INITIAL, the max response time is 160 seconds. Reference Note This command allows establishment of a TCP/UDP connection only when the state is IP INITIAL or IP STATUS when it is in single state. In multi-IP state, the state is in IP STATUS only. So it is necessary to process "AT+CIPSHUT" before user establishes a TCP/UDP connection with this command when the state is not IP INITIAL or IP STATUS. When module is in multi-IP state, before this command is executed, it is necessary to process "AT+CSTT, AT+CIICR, AT+CIFSR". 8.2.3 AT+CIPSEND Send Data Through TCP or UDP Connection AT+CIPSEND Send Data Through TCP or UDP Connection Test Command AT+CIPSEND=? ResponseFor single IP connection (+CIPMUX=0) +CIPSEND: OKFor multi IP connection (+CIPMUX=1) +CIPSEND: (0-5), Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 224 2015-08-03 OK Parameters See Write Command ResponseFor single IP connection (+CIPMUX=0) +CIPSEND: OKFor multi IP connection (+CIPMUX=1) +CIPSEND: , OK Read Command AT+CIPSEND? Parameters A numeric parameter which indicates the connection number A numeric parameter which indicates the data length sent at a time Response This Command is used to send changeable length data If single IP is connected (+CIPMUX=0) If connection is not established or module is disconnected: If error is related to ME functionality: +CME ERROR If sending is successful: When +CIPQSEND=0 SEND OK When +CIPQSEND=1 DATA ACCEPT: If sending fails: SEND FAIL If multi IP connection is established (+CIPMUX=1) If connection is not established or module is disconnected: If error is related to ME functionality: +CME ERROR If sending is successful: When +CIPQSEND=0 ,SEND OK When +CIPQSEND=1 DATA ACCEPT:, If sending fails: ,SEND FAIL Write CommandIf single IP connection (+CIPMUX=0) AT+CIPSEND=< length>If multi IP connection (+CIPMUX=1) AT+CIPSEND=< n>[,] Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 225 2015-08-03 A numeric parameter which indicates the connection number A numeric parameter which indicates the length of sending data, it must be less than Execution Command AT+CIPSEND response">", then type data for send, tap CTRL+Z to send, tap ESC to cancel the operation Response This Command is used to send changeable length data. If single IP connection is established (+CIPMUX=0) If connection is not established or module is disconnected: If error is related to ME functionality: +CME ERROR If sending is successful: When +CIPQSEND=0 SEND OK When +CIPQSEND=1 DATA ACCEPT: If sending fails: SEND FAIL Note This Command can only be used in single IP connection mode (+CIPMUX=0) and to send data on the TCP or UDP connection that has been established already. Ctrl-Z is used as a termination symbol. ESC is used to cancel sending data. There are at most bytes which can be sent at a time. Parameter Saving Mode NO_SAVE Max Response Time When +CIPQSEND=0 and the remote server no response, after 645 seconds, “CLOSE” will be reported. Reference Note The data length which can be sent depends on network status. Set the time that send data automatically with the Command of AT+CIPATS. Only send data at the status of established connection. 8.2.4 AT+CIPQSEND Select Data Transmitting Mode AT+CIPQSEND Select Data Transmitting Mode Response +CIPQSEND: (0,1) OK Test Command AT+CIPQSEND =? Parameters See Write Command Read Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 226 2015-08-03 +CIPQSEND: OK AT+CIPQSEND ? Parameter See Write Command Response OK Write Command AT+CIPQSEND = Parameters 0 Normal mode – when the server receives TCP data, it will responsd SEND OK. 1 Quick send mode – when the data is sent to module, it will responsd DATA ACCEPT:,, while not responding SEND OK. Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.5 AT+CIPACK Query Previous Connection Data Transmitting State AT+CIPACK Query Previous Connection Data Transmitting State Test Command AT+CIPACK=? Response OK Response +CIPACK: , , OK Write Command If in multi IP connection (+CIPMUX=1) AT+CIPACK=< n> Parameters A numeric parameter which indicates the connection number The data amount which has been sent The data amount confirmed successfully by the server The data amount without confirmation by the server Response +CIPACK: , , OK Execution Command If in single IP connection (+CIPMUX=0) AT+CIPACK Parameters See Write Command Parameter Saving Mode NO_SAVE Max Response TimeSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 227 2015-08-03 Reference Note 8.2.6 AT+CIPCLOSE Close TCP or UDP Connection AT+CIPCLOSE Close TCP or UDP Connection Test Command AT+CIPCLOSE =? Response OK Response:For single IP connection (+CIPMUX=0) CLOSE OKFor multi IP connection (+CIPMUX=1) , CLOSE OK Write CommandIf single IP connection (+CIPMUX=0) AT+CIPCLOSE =If multi IP connection (+CIPMUX=1) AT+CIPCLOSE =,[] Parameters 0 Slow close 1 Quick close A numeric parameter which indicates the connection number Execution Command AT+CIPCLOSE Response If close is successfully: CLOSE OK If close fails: ERROR Parameter Saving Mode NO_SAVE Max Response TimeReference Note AT+CIPCLOSE only closes connection at the status of TCP/UDP which returns CONNECTING or CONNECT OK, otherwise it will return ERROR, after the connection is closed, the status is IP CLOSE in single IP mode 8.2.7 AT+CIPSHUT Deactivate GPRS PDP Context AT+CIPSHUT Deactivate GPRS PDP Context Test Command AT+CIPSHUT=? Response OK Execution Command AT+CIPSHUT Response If close is successful: SHUT OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 228 2015-08-03 If close fails: ERROR Parameter Saving Mode NO_SAVE Max Response Time 65 seconds Reference Note If this command is executed in multi-connection mode, all of the IP connection will be shut. User can close gprs pdp context by AT+CIPSHUT. After it is closed, the status is IP INITIAL. If "+PDP: DEACT" urc is reported which means the gprs is released by the network, then user still needs to execute "AT+CIPSHUT" command to make PDP context come back to original state. 8.2.8 AT+CLPORT Set Local Port AT+CLPORT Set Local Port ResponseFor single IP connection (+CIPMUX=0) +CLPORT: ("TCP","UDP"),(0-65535) OKFor multi IP connection (+CIPMUX=1) +CLPORT: (0-5),("TCP","UDP"),(0-65535) OK Test Command AT+CLPORT=? Parameters See Write Command ResponseFor single IP connection (+CIPMUX=0) +CLPORT: , OKFor multi IP connection (+CIPMUX=1) +CLPORT: 0,, +CLPORT: 1,, +CLPORT: 2,, +CLPORT: 3,, +CLPORT: 4,, +CLPORT: 5,, OK Read Command AT+CLPORT? Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 229 2015-08-03 See Write Command Response OK ERROR Write CommandFor single IP connection (+CIPMUX=0) AT+CLPORT=< mode>,For multi IP connection (+CIPMUX=1) AT+CLPORT=< n>,, Parameters 0..5 A numeric parameter which indicates the connection number this used in multi IP connection A string parameter which indicates the connection type "TCP" TCP local port "UDP" UDP local port 0-65535 A numeric parameter which indicates the local port default value is 0, a port can be dynamically allocated a port. Parameter Saving Mode NO_SAVE Max Response TimeReference Note This command will be effective when module is set as a Client. 8.2.9 AT+CSTT Start Task and Set APN, USER NAME, PASSWORD AT+CSTT Start Task and Set APN, USER NAME, PASSWORD Response +CSTT: "APN","USER","PWD" OK Test Command AT+CSTT=? Parameters See Write Command Response +CSTT: ,, OK Read Command AT+CSTT? Parameters See Write Command Response OK ERROR Write Command AT+CSTT=<apn,, Parameters A string parameter which indicates the GPRS access point name A string parameter which indicates the GPRS user name A string parameter which indicates the GPRS password Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 230 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeExecution Command AT+CSTT Response OK ERROR Reference Note The write command and execution command of this command is valid only at the state of IP INITIAL. After this command is executed, the state will be changed to IP START. 8.2.10 AT+CIICR Bring Up Wireless Connection with GPRS or CSD AT+CIICR Bring Up Wireless Connection with GPRS or CSD Test Command AT+CIICR=? Response OK Execution Command AT+CIICR Response OK ERROR Parameter Saving Mode NO_SAVE Max Response Time 85 seconds Reference Note AT+CIICR only activates moving scene at the status of IP START, after operating this Command is executed, the state will be changed to IP CONFIG. After module accepts the activated operation, if it is activated successfully, module state will be changed to IP GPRSACT, and it responds OK, otherwise it will respond ERROR. 8.2.11 AT+CIFSR Get Local IP Address AT+CIFSR Get Local IP Address Test Command AT+CIFSR=? Response OK Response ERROR Execution Command AT+CIFSR Parameter a string parameter which indicates the IP address assigned from GPRS or CSD. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 231 2015-08-03 Parameter Saving Mode NO_SAVE Max Response TimeReference Note Only after PDP context is activated, local IP Address can be obtained by AT+CIFSR, otherwise it will respond ERROR. The active status are IP GPRSACT, TCP/UDP CONNECTING, CONNECT OK, IP CLOSE. 8.2.12 AT+CIPSTATUS Query Current Connection Status AT+CIPSTATUS Query Current Connection Status Test Command AT+CIPSTATUS =? Response OK Response +CIPSTATUS: ,, <TCP/UDP>, , , OK Write Command If multi IP connection mode (+CIPMUX=1) AT+CIPSTATU S= Parameters See Execution Command Response 1)If in single connection mode (+CIPMUX=0) OK STATE: 2) If in multi-connection mode (+CIPMUX=1) OK STATE: If the module is set as server S: 0, , , C: ,, <TCP/UDP>, , , Execution Command AT+CIPSTATUS Parameters 0-5 A numeric parameter which indicates the connection number 0-1 GPRS bearer, default is 0 OPENING LISTENING CLOSING INITIAL CONNECTING CONNECTED Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 232 2015-08-03 REMOTE CLOSING CLOSING CLOSED A string parameter which indicates the progress of connecting 0 IP INITIAL 1 IP START 2 IP CONFIG 3 IP GPRSACT 4 IP STATUS 5 TCP CONNECTING/UDP CONNECTING /SERVER LISTENING 6 CONNECT OK 7 TCP CLOSING/UDP CLOSING 8 TCP CLOSED/UDP CLOSED 9 PDP DEACT In Multi-IP state: 0 IP INITIAL 1 IP START 2 IP CONFIG 3 IP GPRSACT 4 IP STATUS 5 IP PROCESSING 9 PDP DEACT Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.13 AT+CDNSCFG Configure Domain Name Server AT+CDNSCFG Configure Domain Name Server Response +CDNSCFG: ("Primary DNS"),("Secondary DNS") OK Test Command AT+CDNSCFG= ? Parameters See Write Command Read Command AT+CDNSCFG? Response PrimaryDns: <pri_dns> SecondaryDns: <sec_dns> Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 233 2015-08-03 OK Parameter See Write Command Response OK ERROR Write Command AT+CDNSCFG= <pri_dns>[,<sec_ dns>] Parameters <pri_dns> A string parameter which indicates the IP address of the primary domain name server <sec_dns> A string parameter which indicates the IP address of the secondary domain name server Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.14 AT+CDNSGIP Query the IP Address of Given Domain Name AT+CDNSGIP Query the IP Address of Given Domain Name Test Command AT+CDNSGIP= ? Response OK Response OK ERROR If successful, return: +CDNSGIP: 1, ,[,] If fail, return: +CDNSGIP:0, Write Command AT+CDNSGIP= Parameters A string parameter which indicates the domain name A string parameter which indicates the first IP address corresponding to the domain name A string parameter which indicates the second IP address corresponding to the domain name A numeric parameter which indicates the error code 8 DNS COMMON ERROR 3 NETWORK ERROR There are some other error codes as well. Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 234 2015-08-03 Max Response TimeReference Note 8.2.15 AT+CIPHEAD Add an IP Head at the Beginning of a Package Received AT+CIPHEAD Add an IP Head at the Beginning of a Package Received Response +CIPHEAD: (list of supported s) OK Test Command AT+CIPHEAD= ? Parameter See Write Command Response +CIPHEAD: OK Read Command AT+CIPHEAD? Parameters See Write Command Response OK ERROR Write Command AT+CIPHEAD= Parameters A numeric parameter which indicates whether an IP header is added to the received data or not. 0 Not add IP header 1 Add IP header, the format is:For single IP connection (+CIPMUX=0) +IPD,:For multi IP connection (+CIPMUX=1) +RECEIVE,,: Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.16 AT+CIPATS Set Auto Sending Timer AT+CIPATS Set Auto Sending Timer Test Command AT+CIPATS=? Response +CIPATS: (list of supported s),(list of supported ) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 235 2015-08-03 OK Parameters See Write Command Response +CIPATS: , OK Read Command AT+CIPATS? Parameters See Write Command Response OK ERROR Write Command AT+CIPATS=[,] Parameters A numeric parameter which indicates whether set timer when module is sending data 0 Not set timer when module is sending data 1 Set timer when module is sending data 1..100 A numeric parameter which indicates the seconds after which the data will be sent Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.17 AT+CIPSPRT Set Prompt of ‘>’ When Module Sends Data AT+CIPSPRT Set Prompt of ‘>’ When Module Sends Data Response +CIPSPRT: (list of supported s) OK Test Command AT+CIPSPRT=? Parameters See Write Command Response +CIPSPRT: OK Read Command AT+CIPSPRT? Parameters See Write Command Write Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 236 2015-08-03 OK ERROR AT+CIPSPRT=< send prompt> Parameters A numeric parameter which indicates whether to echo prompt ‘>’ after module issues AT+CIPSEND command. 0 It shows "send ok" but does not prompt echo ‘>’ when sending is successful. 1 It prompts echo ‘>’ and shows "send ok" when sending is successful. 2 It neither prompts echo ‘>’ nor shows "send ok" when sending is successful. Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.18 AT+CIPSERVER Configure Module as Server AT+CIPSERVER Configure Module as Server Response +CIPSERVER: (0-CLOSE SERVER, 1-OPEN SERVER),(1-65535) OK Test Command AT+CIPSERVE R=? Parameters See Write Command Response +CIPSERVER: [,,,] OK Read Command AT+CIPSERVE R? Parameters See Write Command Response OK ERROR Write Command AT+CIPSERVE R=[,] Parameters 0 Close server 1 Open server 1..65535 Listening port Channel id GPRS bearer Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 237 2015-08-03 Mode Max Response TimeReference Note This command is allowed to establish a TCP server only when the state is IP INITIAL or IP STATUS when it is in single state. In multi-IP state, the state is in IP STATUS only. 8.2.19 AT+CIPCSGP Set CSD or GPRS for Connection Mode AT+CIPCSGP Set CSD or GPRS for Connection Mode Response +CIPCSGP:0-CSD,DIALNUMBER,USER NAME,PASSWORD,RATE(0-3) +CIPCSGP: 1-GPRS,APN,USER NAME,PASSWORD OK Test Command AT+CIPCSGP=? Parameters See Write Command Response +CIPCSGP: , , , [,] OK Read Command AT+CIPCSGP? Parameters See Write Command Response OK ERROR Write Command AT+CIPCSGP=< mode>[, (,, ),(,,,)] Parameters A numeric parameter which indicates the wireless connection mode 0 set CSD as wireless connection mode 1 set GPRS as wireless connection mode GPRS parameters: A string parameter which indicates the access point name A string parameter which indicates the user name A string parameter which indicates the password CSD parameters: A string parameter which indicates the CSD dial numbers A string parameter which indicates the CSD user name A string parameter which indicates the CSD password A numeric parameter which indicates the CSD connection rate Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 238 2015-08-03 0 2400 1 4800 2 9600 3 14400 Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.20 AT+CIPSRIP Show Remote IP Address and Port When Received Data AT+CIPSRIP Show Remote IP Address and Port When Received Data Response +CIPSRIP: (list of supported s) OK Test Command AT+CIPSRIP=? Parameters See Write Command Response +CIPSRIP: OK Read Command AT+CIPSRIP? Parameters See Write Command Response OK ERROR Write Command AT+CIPSRIP=< mode> Parameters A numeric parameter which shows remote IP address and port. 0 Do not show the prompt 1 Show the prompt, the format is as follows:For single IP connection (+CIPMUX=0) +RECV FROM::For multi IP connection (+CIPMUX=1) +RECEIVE,,,: Parameter Saving Mode NO_SAVE Max Response TimeSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 239 2015-08-03 Reference 8.2.21 AT+CIPDPDP Set Whether to Check State of GPRS Network Timing AT+CIPDPDP Set Whether to Check State of GPRS Network Timing Response +CIPDPDP: (list of supporteds, list of supported , list of supported ) OK Test Command AT+CIPDPDP=? Parameters See Write Command Response +CIPDPDP: , , OK Read Command AT+CIPDPDP? Parameters See Write Command Response OK ERROR Write Command AT+CIPDPDP=< mode>[,<interval,] Parameters0 Not set detect PDP 1 Set detect PDP 1<=interval<=180(s) 1<=timer<=10 Parameter Saving Mode NO_SAVE Max Response TimeReference Note If "+PDP: DEACT" urc is reported because of module not attaching to gprs for a certain time or other reasons, user still needs to execute "AT+CIPSHUT" command makes PDP context come back to original state. 8.2.22 AT+CIPMODE Select TCPIP Application Mode AT+CIPMODE Select TCPIP Application Mode Test Command AT+CIPMODE= Response +CIPMODE: (0-NORMAL MODE,1-TRANSPARENT MODE) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 240 2015-08-03 OK ? Parameters See Write Command Response +CIPMODE: OK Read Command AT+CIPMODE? Parameters See Write Command Response OK ERROR Write Command AT+CIPMODE= Parameters 0 Normal mode 1 Transparent mode Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.23 AT+CIPCCFG Configure Transparent Transfer Mode AT+CIPCCFG Configure Transparent Transfer Mode Response +CIPCCFG: (NmRetry:3-8),(WaitTm:2-10),(SendSz:1-1460),(esc:0,1) ,(Rxmode:0,1), (RxSize:50-1460),(Rxtimer:20-1000) OK Test Command AT+CIPCCFG= ? Parameters See Write Command Response +CIPCCFG: ,,,,,, OK Read Command AT+CIPCCFG? Parameters See Write Command Write Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 241 2015-08-03 OK ERROR AT+CIPCCFG= ,,, [,<Rxmode,,] Parameters Number of retries to be made for an IP packet. Number of 100ms intervals to wait for serial input before sending the packet. Size in bytes of data block to be received from serial port before sending. Whether turn on the escape sequence, default is TRUE. 0 Turn off the escape sequence 1 Turn on the escape sequence Whether to set time interval during output data from serial port. 0 output data to serial port without interval 1 output data to serial port within interval. Output data length for each time, default value is 1460. Time interval (ms) to wait for serial port to output data again. Default value: 50ms Parameter Saving Mode NO_SAVE Max Response TimeReference Note This command will be effective only in single connection mode (+CIPMUX=0) 8.2.24 AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data AT+CIPSHOWTP Display Transfer Protocol in IP Head When Received Data Response +CIPSHOWTP: (list of supported s) OK Test Command AT+CIPSHOWTP =? Parameters See Write Command Response +CIPSHOWTP: OK Read Command AT+CIPSHOWTP ? Parameters See Write Command Write Command AT+CIPSHOWTP Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 242 2015-08-03 = ERROR Parameters A numeric parameter which indicates whether to display transfer protocol in IP header to received data or not 0 Not display transfer protocol 1 Display transfer protocol, the format is "+IPD, ,<TCP/UDP>:" Parameter Saving Mode NO_SAVE Max Response Time - Reference Note This command will be effective only in single connection mode (+CIPMUX=0). Only when +CIPHEAD is set to 1, the setting of this command will work. 8.2.25 AT+CIPUDPMODE UDP Extended Mode AT+CIPUDPMODE UDP Extended Mode ResponseFor single IP connection (+CIPMUX=0) +CIPUDPMODE: (0-2),("(0-255).(0-255).(0-255).(0-255)"),(1-65535) OKFor multi IP connection (+CIPMUX=1) +CIPUDPMODE: (0-5),(0-2),("(0-255).(0-255).(0-255).(0-255)"),(1-65535) OK Test Command AT+CIPUDPMOD E=? Parameters See Write Command Read Command AT+CIPUDPMOD E? ResponseFor single IP connection (+CIPMUX=0) +CIPUDPMODE: [,,] OKFor multi IP connection (+CIPMUX=1) +CIPUDPMODE: 0, [,,] +CIPUDPMODE: 1,[,,] +CIPUDPMODE: 2,[,,] +CIPUDPMODE: 3,[,,] +CIPUDPMODE: 4,[,,] +CIPUDPMODE: 5,[,,] Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 243 2015-08-03 OK Parameter See Write Command Response OK ERROR Write CommandFor single IP connection (+CIPMUX=0) AT+CIPUDPMOD E=[,,]For multi IP connection (+CIPMUX=1) AT+CIPUDPMOD E=,[,,] 0-5 A numeric parameter which indicates the connection number 0 UDP Normal Mode 1 UDP Extended Mode 2 Set UDP address to be sent A string parameter which indicates remote IP address Remote port Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 8.2.26 AT+CIPRXGET Get Data from Network Manually AT+CIPRXGET Get Data from Network Manually Response If single IP connection (+CIPMUX=0) +CIPRXGET: (list of supported s),(list of supported ) OK If multi IP connection (+CIPMUX=1) +CIPRXGET: (list of supported s), (list of supported s), (list of supported ) OK Test Command AT+CIPRXGET =? Parameters See Write Command Read Command AT+CIPRXGET ? Response +CIPRXGET: OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 244 2015-08-03 Parameters See Write Command Response OK ERROR 1)For single IP connection If “AT+CIPSRIP=1” is set, IP address and port are contained. if =1 +CIPRXGET: 1[,:] if =2 +CIPRXGET: 2,,[,:] 1234567890… OK if =3 +CIPRXGET: 3,,[,:] 5151… OK if =4 +CIPRXGET: 4, OK 2)For multi IP connection If “AT+CIPSRIP=1” is set, IP address and port is contained. if =1 +CIPRXGET: 1[,,:] if =2 +CIPRXGET: 2,,,[,:] 1234567890… OK if =3 +CIPRXGET: 3,,,[,:] 5151… OK if =4 +CIPRXGET: 4, , OK If error is related to ME functionality: +CME ERROR: Write CommandIf single IP connection (+CIPMUX=0) AT+CIPRXGET =[,]If multi IP connection (+CIPMUX=1) AT+CIPRXGET =[,,< reqlength>] ParametersSmart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 245 2015-08-03 0 Disable getting data from network manually, the module is set to normal mode, data will be pushed to TE directly. 1 Enable getting data from network manually. 2 The module can get data, but the length of output data can not exceed 1460 bytes at a time. 3 Similar to mode 2, but in HEX mode, which means the module can get 730 bytes maximum at a time. 4 Query how many data are not read with a given ID. A numeric parameter which indicates the connection number Requested number of data bytes (1-1460 bytes)to be read Confirmed number of data bytes to be read, which may be less than . 0 indicates that no data can be read. Parameter Saving Mode NO_SAVE Max Response TimeReference Note To enable this function, parameter must be set to 1 before connection. 8.2.27 AT+CIPSCONT Save TCPIP Application Context AT+CIPSCONT Save TCPIP Application Context Read Command AT+CIPSCONT ? Response TA returns TCPIP Application Context, which consists of the following AT Command parameters. +CIPSCONT: +CIPCSGP: Gprs Config APN: Gprs Config UserId: Gprs Config Password: +CIPHEAD: +CIPSHOWTP: +CIPSRIP: +CIPATS: , +CIPSPRT: , +CIPQSEND: +CIPMODE: +CIPCCFG: ,,,,,, +CIPMUX: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 246 2015-08-03 +CIPDPDP: , , +CIPRXGET: +CIPRDTIMER: , OK Parameters 0 Saved, the value from NVRAM 1 Unsaved, the value from RAM For other parameters, see the related command. Execution Command AT+CIPSCONT Response Module saves current TCPIP Application Contexts to NVRAM. When system is rebooted, the parameters will be loaded automatically. OK Parameter Saving Mode NO_SAVE Max Response TimeReference Note 8.2.28 AT+CIPRDTIMER Set Remote Delay Timer AT+CIPRDTIMER Set Remote Delay Timer Response +CIPRDTIMER: (100-4000),(100-7000) OK Test Command AT+CIPRDTIM ER=? Parameters See Write Command Response +CIPRDTIMER: ,OK Read Command AT+CIPRDTIM ER? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CIPRDTIM ER=<rdsigtimer, Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 247 2015-08-03 remote delay timer of single connection. remote delay timer of multi-connections. Parameter Saving Mode NO_SAVE Max Response TimeReference Note This command is used to shorten the disconnect time locally when the remote server has been disconnected. 8.2.29 AT+CIPSGTXT Select GPRS PDP context AT+CIPSGTXT Select GPRS PDP context Response +CIPSGTXT: (0,1) OK Test Command AT+CIPSGTXT =? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+CIPSGTXT = Parameters 0 select first PDP context 1 select second PDP context Parameter Saving Mode NO_SAVE Max Response TimeReference Note This command is used to select pdp context, only for multi IP connection (+CIPMUX=1). Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 248 2015-08-03 8.2.30 AT+CIPTKA Set TCP Keepalive Parameters AT+CIPTKA Set TCP Keepalive Parameters Response +CIPTKA: (list of supported s),(list of supported s),(list of supported ),(list of supported s) OK Test Command AT+CIPTKA=? Parameters See Write Command Response +CIPTKA: ,,, OK Read Command AT+CIPTKA? Parameters See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+CIPTKA= [,[,[,]]] Parameters Set TCP keepalive option. 0 Disable TCP keep alive mechanism 1 Enable TCP keep alive mechanism Integer type; Idle time (in second) before TCP send the initial keepalive probe. 30-7200 Default: 7200 Interval time (in second) between keepalive probes retransmission. 30-600 Default: 75 Integer type; Maximum number of keepalive probes to be sent. 1-9 Default: 9 Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 249 2015-08-03 9 AT Commands for IP Application 9.1 Overview Command Description AT+SAPBR Bearer settings for applications based on IP 9.2 Detailed Descriptions of Commands 9.2.1 AT+SAPBR Bearer Settings for Applications Based on IP AT+SAPBR Bearer Settings for Applications Based on IP Response +SAPBR: (0-4),(1-3), "ConParamTag","ConParamValue" OK Test Command AT+SAPBR=? Parameters See Write Command Response OK If<cmd_type> = 2 +SAPBR: ,,<IP_Addr> OK If <cmd_type>=4 +SAPBR: , OK Unsolicited Result Code +SAPBR : DEACT Write Command AT+SAPBR=,[ ,<ConParamTag,] Parameters <cmd_type> 0 Close bearer 1 Open bearer 2 Query bearer 3 Set bearer parameters 4 Get bearer parametersBearer profile identifier 0 Bearer is connecting 1 Bearer is connected Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 250 2015-08-03 2 Bearer is closing 3 Bearer is closed Bearer parameter "CONTYPE" Type of Internet connection. Value refer to <ConParamValue_ConType> "APN" Access point name string: maximum 64 characters "USER" User name string: maximum 32 characters "PWD" Password string: maximum 32 characters "PHONENUM" Phone number for CSD call "RATE" CSD connection rate. For value refer to <ConParamValue_Rate> Bearer paramer value <ConParamValue_ConType> "CSD" Circuit-switched data call. "GPRS" GPRS connection. <ConParamValue_Rate> 0 2400 1 4800 2 9600 3 14400 <IP_Addr> The IP address of bearer Parameter Saving Mode NO_SAVE Max Response Time When <cmd_type> is 1, 85 seconds When <cmd_type> is 0, 65 seconds Reference Note This command is applied to activate some applications such as HTTP, FTP. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 251 2015-08-03 10 AT Commands for PING Support 10.1 Overview Command Description AT+CIPPING Ping request AT+CIPCTL Set the mode when receiving an IP packet AT+CIPFLT Set the rules of IP filter AT+CIPBEIPING Set the module to be PING or not 10.2 Detailed Descriptions of Commands 10.2.1 AT+CIPPING PING Request AT+CIPPING PING Request Response +CIPPING: (list of supported s),(list of supported s),(list of supported s),(list of supported s) OK Test Command AT+CIPPING=? Parameters See Write Command Response +CIPPING: ,,, OK Read Command AT+CIPPING? Parameters See Write Command Write Command AT+CIPPING=[,<retryNum[,[,[,]]]] Response +CIPPING: ,,,[ +CIPPING: ,,, [...]] OK or ERROR or +CME ERROR: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 252 2015-08-03 Parameters Address of the remote host,string type.This parameter can be either:IP address in the format:”xxx.xxx.xxx.xxx”Host name solved by a DNS query The number of Ping Echo Requset to send 1-100 Default: 4 The length of Ping Echo Request data 0-1024 Default: 32 The timeout,in units of 100 ms,waiting for a single Echo Reply 1-600 Default: 100(10 seconds) Time to live 1-255 Default: 64 Echo Reply number IP Address of the remote host Time,in units of 100 ms, required to receive the response Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Before sending PING Request the GPRS context must be activated. When the Echo Request timeout expires (no reply received on time), the response will contains setting to 600 and setting to 255. When executing this command, if PDP context is deactivated for some reasons, such as out of service, etc., the “+PDP: DEACT” URC is reported and the command will end immediately. 10.2.2 AT+CIPCTL Set the Mode When Receiving an IP Packet AT+CIPCTL Set the Mode When Receiving an IP Packet Response +CIPCTL: (list of supported s) OK Test Command AT+CIPCTL=? Parameters See Write Command Read Command AT+CIPCTL? Response +CIPCTL: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 253 2015-08-03 OK Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CIPCTL= Parameters 0 Disable to send Echo Reply 1 Enable to send Echo Reply to every IP address pinging it 2 Enable to send Echo Reply only to a subset of IP Addresses pinging it. This subset of IP Addresses can be set by “AT+CIPFLT” command. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note The value of is stored in non volatile memory. 10.2.3 AT+CIPFLT Set the Rules of IP Filter AT+CIPFLT Set the Rules of IP Filter Response +CIPFLT: (list of supported s),(list of supported s) OK Test Command AT+CIPFLT=? Parameters See Write Command Response +CIPFLT: ,, [+CIPFLT: ,, […]] OK Read Command AT+CIPFLT? Parameter See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 254 2015-08-03 Response OK or ERROR or +CME ERROR: Write Command AT+CIPFLT=[,][, ,] Parameters 0 Remove the rule specified by . must be given. 1 Add the rule specified by . If is not given, it can find an empty item automatically. and must be given. 2 Delete all of rules The item of IP filter rule 1-20 Remote IP address,string type. It can be any valid IP address in the format of ”xxx.xxx.xxx.xxx” Mask to be applied to the,string type. It can be any valid IP address mask in the format of ”xxx.xxx.xxx.xxx” Parameter Saving Mode NO_SAVE Max Response Time - Reference Note When a packet comes from the IP address <coming_IP>, All rules will be scanned to match the following criterion: <coming_IP> & = & If the criterion is matched, the IP packet will be accepted and the rule scan is finished. If the criterion is not matched, the IP packet will be ignored. The rule is stored in non volatile memory. 10.2.4 AT+CIPBEIPING Set the Module to be PING or Not AT+CIPBEIPING Set the Module to be PING or Not Response +CIPBEIPING: (0,1) OK Test Command AT+CIPBEIPING= ? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 255 2015-08-03 Response +CIPBEIPING: OK Read Command AT+CIPBEIPING? Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CIPBEIPING=Parameters 0 Disable the module to be PING. 1 Enable the module to be PING. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note If the user want the module can be PING by other device, the user must excute the AT+CIPBEIPING=1 before the module is PING. Part of the projects supported by this AT command, please refer to chapter 21 for details. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 256 2015-08-03 11 AT Commands for HTTP Application SIM800 series has an embedded TCP/IP stack that is driven by AT commands and enables the host application to easily access the Internet HTTP service. This chapter is a reference guide to all the AT commands and responses defined to use with the TCP/IP stack in HTTP Service. 11.1 Overview Command Description AT+HTTPINIT Initialize HTTP service AT+HTTPTERM Terminate HTTP service AT+HTTPPARA Set HTTP parameters value AT+HTTPDATA Input HTTP data AT+HTTPACTION HTTP method action AT+HTTPREAD Read the HTTP server response AT+HTTPSCONT Save HTTP application context AT+HTTPSTATUS Read HTTP status AT+HTTPHEAD Read the HTTP header information of server response 11.2 Detailed Descriptions of Commands 11.2.1 AT+HTTPINIT Initialize HTTP Service AT+HTTPINIT Initialize HTTP Service Test Command AT+HTTPINIT= ? Response OK Execution Command AT+HTTPINIT Response OK If error is related to ME functionality: +CME ERROR: Parameter Saving Mode NO_SAVE Max Response TimeReference Note HTTPINIT should first be executed to initialize the HTTP service. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 257 2015-08-03 11.2.2 AT+HTTPTERM Terminate HTTP Service AT+HTTPTERM Terminate HTTP Service Test Command AT+HTTPTER M=? Response OK Execution command AT+HTTPTER M Response OK If error is related to ME functionality: +CME ERROR: Parameter Saving Mode NO_SAVE Max Response TimeReference Note 11.2.3 AT+HTTPPARA Set HTTP Parameters Value AT+HTTPPARA Set HTTP Parameters Value Response +HTTPPARA: "HTTPParamTag","HTTPParmValue" OK Test Command AT+HTTPPARA =? Parameters See Write Command Response +HTTPPARA: , OK Read Command AT+HTTPPARA ? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+HTTPPARA =, Parameters "CID"HTTP Parameter (Mandatory Parameter) Bearer profile identifier Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 258 2015-08-03 "URL" "UA" "PROIP" "PROPORT" "REDIR" "BREAK" "BREAKEND" "TIMEOUT" "CONTENT" "USERDATA" (Mandatory Parameter) HTTP client URL "http://'server'/'path':'tcpPort' " "server": FQDN or IP-address "path": path of file or directory "tcpPort": default value is 80. Refer to "IETF-RFC 2616". The user agent string which is set by the application to identify the mobile. Usually this parameter is set as operation system and software version information. Default value is "SIMCom_MODULE". The IP address of HTTP proxy server The port of HTTP proxy server This flag controls the redirection mechanism of the SIM800 when it is acting as HTTP client (numeric). If the server sends a redirect code (range 30x), the client will automatically send a new HTTP request when the flag is set to (1). Default value is 0 (no redirection). Parameter for HTTP method "GET", used for resuming broken transfer. Parameter for HTTP method "GET", used for resuming broken transfer. which is used together with "BREAK", If the value of "BREAKEND" is bigger than "BREAK", the transfer scope is from "BREAK" to "BREAKEND". If the value of "BREAKEND" is smaller than "BREAK", the transfer scope is from "BREAK" to the end of the file. If both "BREAKEND" and "BREAK" are 0, the resume broken transfer function is disabled. HTTP session timeout value, scope: 30-1000 second. Default value is 120 seconds. HTTP Parameter value. Type and supported content depend on related . Used to set the “Content-Type” field in HTTP header. User data HTTP Parameter value.Type and supported content depend on related . Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 259 2015-08-03 Mode Max Response TimeReference Note Not all the HTTP Server supports "BREAK" and "BREAKEND" parameters 11.2.4 AT+HTTPDATA Input HTTP Data AT+HTTPDATA Input HTTP Data Response +HTTPDATA: (list of supported s),(list of supported s) OK Test Command AT+HTTPDATA =? Parameters See Write Command Response DOWNLOAD OK If error is related to ME functionality: +CME ERROR: Write Command AT+HTTPDATA =, Parameters Size in bytes of the data to POST. 1-319488 (bytes) 0 means delete all the content. 1000-120000 (millisecond) Maximum time in milliseconds to input data. Parameter Saving Mode NO_SAVE Max Response TimeReference Note It is strongly recommended to set enough time to input all data with the length of . 11.2.5 AT+HTTPACTION HTTP Method Action AT+HTTPACTION HTTP Method Action Test Command AT+HTTPACTI ON=? Response +HTTPACTION: (0-2) OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 260 2015-08-03 Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Unsolicited Result Code +HTTPACTION: ,, Write Command AT+HTTPACTI ON= Parameters HTTP method specification: 0 GET 1 POST 2 HEAD HTTP Status Code responded by remote server, it identifier refer to HTTP1.1(RFC2616) 100 Continue 101 Switching Protocols 200 OK 201 Created 202 Accepted 203 Non-Authoritative Information 204 No Content 205 Reset Content 206 Partial Content 300 Multiple Choices 301 Moved Permanently 302 Found 303 See Other 304 Not Modified 305 Use Proxy 307 Temporary Redirect 400 Bad Request 401 Unauthorized 402 Payment Required 403 Forbidden 404 Not Found 405 Method Not Allowed 406 Not Acceptable 407 Proxy Authentication Required 408 Request Time-out 409 Conflict 410 Gone Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 261 2015-08-03 411 Length Required 412 Precondition Failed 413 Request Entity Too Large 414 Request-URI Too Large 415 Unsupported Media Type 416 Requested range not satisfiable 417 Expectation Failed 500 Internal Server Error 501 Not Implemented 502 Bad Gateway 503 Service Unavailable 504 Gateway Time-out 505 HTTP Version not supported 600 Not HTTP PDU 601 Network Error 602 No memory 603 DNS Error 604 Stack Busy The length of data got Parameter Saving Mode NO_SAVE Max Response Time About 5 seconds in test, dependence on network status and the size of request website Reference Note 11.2.6 AT+HTTPREAD Read the HTTP Server Response AT+HTTPREAD Read the HTTP Server Response Response +HTTPREAD: (list of supported <start_address>s),(list of supported <byte_size>s) OK Test Command AT+HTTPREA D=? Parameters See Write Command Write Command AT+HTTPREA D=<start_addres s>,<byte_size> Response +HTTPREAD: <date_len> OK Read data when AT+HTTPACTION=0 or AT+HTTPDATA is executed. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 262 2015-08-03 If<byte_size> is bigger than the data size received, module will only return actual data size. If error is related to ME functionality: +CME ERROR: Parameters Data from HTTP server or user input. <start_address> The starting point for data output. 0-319488 (bytes) <byte_size> The length for data output. 1-319488 (bytes) <data_len> The actual length for data output. Execution Command AT+HTTPREA D Response +HTTPREAD:<date_len> OK Read all data when AT+HTTPACTION=0 or AT+HTTPDATA is executed. If error is related to ME functionality: +CME ERROR: Parameter Saving Mode NO_SAVE Max Response TimeReference Note 11.2.7 AT+HTTPSCONT Save HTTP Application Context AT+HTTPSCONT Save HTTP Application Context Read Command AT+HTTPSCON T? Response TA returns HTTP Application Context, which consists of the following AT Command parameters. +HTTPSCONT: CID: URL: UA: PROIP: PROPORT: REDIR: BREAK: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 263 2015-08-03 BREAKEND: USERDATA: OK Parameters 0 Saved, the value from NVRAM 1 Unsaved, the value from RAM For other parameters, see the related command. Response TA saves HTTP Application Context which consists of following AT Command parameters, and when system is rebooted, the parameters will be loaded automatically. OK If error is related to ME functionality: +CME ERROR: Execution Command AT+HTTPSCON T Parameters Parameter Saving Mode NO_SAVE Max Response TimeReference Note This command can only be used after run AT+HTTPINIT. 11.2.8 AT+HTTPSTATUS Read HTTP Status AT+HTTPSTATUS Read HTTP Status Test Command AT+HTTPSTAT US=? Response OK Read Command AT+HTTPSTAT US? Response +HTTPSTATUS: ,,, OK If error is related to ME functionality: +CME ERROR: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 264 2015-08-03 Parameters: GET POST HEAD 0 idle 1 receiving 2 sending The amount of data which have been transmitted The amount of data remaining to be sent or received Parameter Saving Mode NO_SAVE Max Response Time11.2.9 AT+HTTPHEAD Read the HTTP Header Information of Server Response AT+HTTPHEAD Read the HTTP Header Information of Server Response Test Command AT+HTTPHEAD =? Response OK ResponseHTTPHEAD: <date_len>OK If error is related to ME functionality: +CME ERROR: Execution Command AT+HTTPHEAD Parameters <data_len> The actual length for http header data output Data from HTTP server Parameter Saving Mode NO_SAVE Max Response TimeReference Note Read header data when AT+HTTPACTION=0 executed. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 265 2015-08-03 12 AT Commands for FTP Application SIM800 series has an embedded TCP/IP stack that is driven by AT commands and enables the host application to easily access the Internet FTP service. This chapter is a reference guide to all the AT commands and responses defined for using with the TCP/IP stack in FTP Service. 12.1 Overview Command Description AT+FTPPORT Set FTP control port AT+FTPMODE Set active or passive FTP mode AT+FTPTYPE Set the type of data to be transferred AT+FTPPUTOPT Set FTP put type AT+FTPCID Set FTP bearer profile identifier AT+FTPREST Set resume broken download AT+FTPSERV Set FTP server address AT+FTPUN Set FTP user name AT+FTPPW Set FTP password AT+FTPGETNAME Set download file name AT+FTPGETPATH Set download file path AT+FTPPUTNAME Set upload file name AT+FTPPUTPATH Set upload file path AT+FTPGET Download file AT+FTPPUT Set upload file AT+FTPSCONT Save FTP application context AT+FTPDELE Delete specified file in FTP server AT+FTPSIZE Get the size of specified file in FTP server AT+FTPSTATE Get the FTP state AT+FTPEXTPUT Extend upload file AT+FTPMKD Make directory on the remote machine AT+FTPRMD Remove directory on the remote machine AT+FTPLIST List contents of directory on the remote machine AT+FTPGETTOFS Download file and save in file system AT+FTPPUTFRMFS Upload file from file system AT+FTPEXTGET Extend download file AT+FTPFILEPUT Load file in RAM from file system then upload with FTPPUT AT+FTPQUIT Quit current FTP session Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 266 2015-08-03 12.2 Detailed Descriptions of Commands 12.2.1 AT+FTPPORT Set FTP Control Port AT+FTPPORT Set FTP Control Port Test Command AT+FTPPORT= ? Response OK Response +FTPPORT: OK Read Command AT+FTPPORT? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPPORT= Parameters The value of FTP Control port, from 1 to 65535. Default value is 21 Parameter Saving Mode NO_SAVE Max Response TimeReference Note Numbers above 65535 are illegal as the port identification fields are 16 bits long in the TCP header. 12.2.2 AT+FTPMODE Set Active or Passive FTP Mode AT+FTPMODE Set Active or Passive FTP Mode Test Command AT+FTPMODE =? Response OK Response +FTPMODE: OK Read Command AT+FTPMODE? Parameters See Write Command Write Command AT+FTPMODE Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 267 2015-08-03 If error is related to ME functionality: +CME ERROR: = Parameters 0 Active FTP mode 1 Passive FTP mode Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.3 AT+FTPTYPE Set the Type of Data to Be Transferred AT+FTPTYPE Set the Type of Data to Be Transferred Test Command AT+FTPTYPE= ? Response OK Response +FTPTYPE: OK Read Command AT+FTPTYPE? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPTYPE= Parameters "A" For FTP ASCII sessions "I" For FTP Binary sessions Parameter Saving Mode NO_SAVE Max Response TimeReference Note When this value is set to A, all the data sent by the stack to the FTP server is made of 7 bits characters (NVT-ASCII: the MSB is set to 0). As a consequence binary data containing 8 bits characters will be corrupted during the transfer if the FTPTYPE is set to A. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 268 2015-08-03 12.2.4 AT+FTPPUTOPT Set FTP Put Type AT+FTPPUTOPT Set FTP Put Type Test Command AT+FTPPUTOP T=? Response OK Response +FTPPUTOPT: OK Read Command AT+FTPPUTOP T? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPPUTOP T= Parameters "APPE" For appending file "STOU" For storing unique file "STOR" For storing file Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.5 AT+FTPCID Set FTP Bearer Profile Identifier AT+FTPCID Set FTP Bearer Profile Identifier Response OK Test Command AT+FTPCID=? Parameters See Write Command Response +FTPCID: OK Read Command AT+FTPCID? Parameter See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 269 2015-08-03 Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPCID= Parameters Bearer profile identifier refer to AT+SAPBR Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.6 AT+FTPREST Set Resume Broken Download AT+FTPREST Set Resume Broken Download Test Command AT+FTPREST= ? Response OK Response +FTPREST: OK Read Command AT+FTPREST? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPREST= Parameters Broken point to be resumed Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.7 AT+FTPSERV Set FTP Server Address AT+FTPSERV Set FTP Server Address Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 270 2015-08-03 Test Command AT+FTPSERV= ? Response OK Response +FTPSERV: OK Read Command AT+FTPSERV? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPSERV= Parameters 32-bit number in dotted-decimal notation (i.e. xxx.xxx.xxx.xxx) or alphanumeric ASCII text string up to 49 characters if DNS is available Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.8 AT+FTPUN Set FTP User Name AT+FTPUN Set FTP User Name Response OK Test Command AT+FTPUN=? Parameters See Write Command Response +FTPUN: OK Read Command AT+FTPUN? Parameters See Write Command Write Command AT+FTPUN= Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 271 2015-08-03 If error is related to ME functionality: +CME ERROR: Parameters Alphanumeric ASCII text string up to 49 characters. Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.9 AT+FTPPW Set FTP Password AT+FTPPW Set FTP Password Response OK Test Command AT+FTPPW=? Parameters See Write Command Response +FTPPW: OK Read Command AT+FTPPW? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPPW= Parameter Alphanumeric ASCII text string up to 49 characters. Parameter Saving Mode NO_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 272 2015-08-03 12.2.10 AT+FTPGETNAME Set Download File Name AT+FTPGETNAME Set Download File Name Test Command AT+FTPGETNA ME=? Response OK Response +FTPGETNAME: OK Read Command AT+FTPGETNA ME? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPGETNA ME= Parameters Alphanumeric ASCII text string up to 99 characters Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.11 AT+FTPGETPATH Set Download File Path AT+FTPGETPATH Set Download File Path Test Command AT+FTPGETPA TH=? Response OK Response +FTPGETPATH: OK Read Command AT+FTPGETPA TH? Parameters See Write Command Write Command AT+FTPGETPA TH= Response OK If error is related to ME functionality: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 273 2015-08-03 +CME ERROR: Parameters Alphanumeric ASCII text string up to 255 characters Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.12 AT+FTPPUTNAME Set Upload File Name AT+FTPPUTNAME Set Upload File Name Test Command AT+FTPPUTNA ME=? Response OK Response +FTPPUTNAME: OK Read Command AT+FTPPUTNA ME? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPPUTNA ME= Parameters Alphanumeric ASCII text string up to 99 characters Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.13 AT+FTPPUTPATH Set Upload File Path AT+FTPPUTPATH Set Upload File Path Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 274 2015-08-03 Test Command AT+FTPPUTPA TH=? Response OK Response +FTPPUTPATH: OK Read Command AT+FTPPUTPA TH? Parameters See Write Command Response OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPPUTPA TH= Parameters Alphanumeric ASCII text string up to 255 characters Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.14 AT+FTPGET Download File AT+FTPGET Download File Test Command AT+FTPGET=? Response OK Write Command AT+FTPGET=< mode>[,] Response If mode is 1 and it is a successful FTP get session: OK +FTPGET:1,1 If data transfer finished: +FTPGET:1,0 If mode is 1 and it is a failed FTP get session: OK +FTPGET:1, If mode is 2: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 275 2015-08-03 +FTPGET:2, 012345678… OK If error is related to ME functionality: +CME ERROR: Parameters 1 For opening FTP get session 2 For reading FTP download data. Requested number of data bytes (1-1460)to be read Confirmed number of data bytes to be read, which may be less than . 0 indicates that no data can be read. 61 Net error 62 DNS error 63 Connect error 64 Timeout 65 Server error 66 Operation not allow 70 Replay error 71 User error 72 Password error 73 Type error 74 Rest error 75 Passive error 76 Active error 77 Operate error 78 Upload error 79 Download error 86 Manual quit Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note When "+FTPGET:1,1" is shown, then use AT+FTPGET=2, to read data. If the module still has unread data, "+FTPGET:1,1" will be shown again in a certain time. 12.2.15 AT+FTPPUT Set Upload File AT+FTPPUT Set Upload File Test Command AT+FTPPUT=? Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 276 2015-08-03 Response If mode is 1 and it is a successful FTP get session: OK +FTPPUT:1,1,If mode is 1 and it is a failed FTP get session: OK +FTPPUT:1, If mode is 2 and is not 0 +FTPPUT:2, …… //Input data OK If mode is 2 and is 0, it will respond OK, and FTP session will be closed OK If data transfer finished. +FTPPUT:1,0 If error is related to ME functionality: +CME ERROR: Write Command AT+FTPPUT=< mode>[,] Parameters 1 For opening FTP put session 2 For writing FTP upload data. Requested number of data bytes(0-) to be transmitted Confirmed number of data bytes to be transmitted The max length of data can be sent at a time. It depends on the network status. See "AT+FTPGET" Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note When "+FTPPUT:1,1," is shown, then use "AT+FTPPUT=2, " to write data. 12.2.16 AT+FTPSCONT Save FTP Application Context AT+FTPSCONT Save FTP Application Context Read Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 277 2015-08-03 TA returns FTP Application Context, which consists of the following AT Command parameters. +FTPSCONT: +FTPSERV: +FTPPORT: +FTPUN: +FTPPW: +FTPCID: +FTPMODE: +FTPTYPE: +FTPPUTOPT: +FTPREST: +FTPGETNAME: +FTPGETPATH: +FTPPUTNAME: +FTPPUTPATH: +FTPTIMEOUT: OK AT+FTPSCONT ? Parameters 0 Saved, the value from NVRAM 1 Unsaved, the value from RAM For other parameters, see the related command. Execution Command AT+FTPSCONT Response TA saves FTP Application Context which consists of following AT Command parameters, and when system is rebooted, the parameters will be loaded automatically. OK Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.17 AT+FTPDELE Delete Specified File in FTP Server AT+FTPDELE Delete Specified File in FTP Server Response OK Test Command AT+FTPDELE=? Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 278 2015-08-03 Response If successed: OK +FTPDELE:1,0If failed: OK +FTPDELE:1, If error is related to ME functionality: +CME ERROR: Execution Command AT+FTPDELE Parameters See "AT+FTPGET" Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note The file to be deleted is specified by the "AT+FTPGETNAME" and "AT+FTPGETPATH" commands. 12.2.18 AT+FTPSIZE Get the Size of Specified File in FTP Server AT+FTPSIZE Get the Size of Specified File in FTP Server Response OK Test Command AT+FTPSIZE=? Parameters Execution Command AT+FTPSIZE Response If successed: OK +FTPSIZE:1,0,If failed: OK +FTPSIZE:1,,<0> If error is related to ME functionality: +CME ERROR: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 279 2015-08-03 Parameters See "AT+FTPGET" The file size. Unit: byte Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note The file is specified by the "AT+FTPGETNAME" and "AT+FTPGETPATH" commands. 12.2.19 AT+FTPSTATE Get the FTP State AT+FTPSTATE Get the FTP State Response OK Test Command AT+FTPSTATE=? Parameters Response +FTPSTATE: OK If error is related to ME functionality: +CME ERROR: Execution Command AT+FTPSTATE Parameters 0 Idle 1 In the FTP session, including FTPGET, FTPPUT, FTPDELE and FTPSIZE operation. Parameter Saving Mode NO_SAVE Max Response TimeReference Note 12.2.20 AT+FTPEXTPUT Extend Upload File AT+FTPEXTPUT Extend Upload File Test Command AT+FTPEXTPUT =? Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 280 2015-08-03 Response If mode is 0 or 1 OK If mode is 2 +FTPEXTPUT: , If error is related to ME functionality: +CME ERROR: Write Command AT+FTPEXTPUT =[,,< len>,] Parameters 0 use default FTPPUT method 1 use extend FTPPUT method 2 download data which need to PUT to RAM data offset address 0-300k data length 0-300k timeout value of serial port 1000ms-1000000ms Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note When extend FTPPUT mode is activated, input data then execute "AT+FTPPUT=1" to transmit, after session is complete, if successful, it returns "+FTPPUT: 1,0", otherwise it returns "+FTPPUT: 1,", see "AT+FTPGET". 12.2.21 AT+FTPMKD Make Directory on the Remote Machine AT+FTPMKD Make Directory on the Remote Machine Test Command AT+FTPMKD=? Response OK Response If success: OK +FTPMKD: 1,0 If failed: OK +FTPMKD: 1, If error is related to ME functionality: +CME ERROR: Execution Command AT+FTPMKD Parameters See "AT+FTPGET" Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 281 2015-08-03 Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note The created folder is specified by the "AT+FTPGETPATH" command. 12.2.22 AT+FTPRMD Remove Directory on the Remote Machine AT+FTPRMD Remove Directory on the Remote Machine Test Command AT+FTPRMD=? Response OK Response If success: OK +FTPRMD: 1,0 If failed: OK +FTPRMD: 1, If error is related to ME functionality: +CME ERROR: Execution Command AT+FTPRMD Parameters See "AT+FTPGET" Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note The removed folder is specified by the "AT+FTPGETPATH" command. 12.2.23 AT+FTPLIST List Contents of Directory on the Remote Machine AT+FTPLIST List Contents of Directory on the Remote Machine Test Command AT+FTPLIST=? Response OK Write Command AT+FTPLIST=[, ] Response If mode is 1 and it is a successful FTP get session: OK +FTPLIST: 1,1 If data transfer is finished: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 282 2015-08-03 +FTPLIST: 1,0 If mode is 1 and it is a failed FTP get session: OK +FTPLIST: 1, If mode is 2: +FTPLIST: 2, 012345678… OK If error is related to ME functionality: +CME ERROR: Parameters 1 For opening FTP get file list session 2 For reading FTP file list Requested number of data bytes (1-1460) to be read Confirmed number of data bytes to be read, which may be less than . 0 indicates that no data can be read. See "AT+FTPGET" Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note When "+FTPLIST: 1,1" is shown, "AT+FTPLIST=2," can be used to read data. If the module still has unread data, "+FTPLIST: 1,1" will be shown again in a certain time. 12.2.24 AT+FTPGETTOFS Download File and Save in File System AT+FTPGETTOFS Download File and Save in File System Test Command AT+FTPGETTO FS=? Response OK Response +FTPGETTOFS: [,,] OK Read Command AT+FTPGETTO FS? Parameters the process status of downloading and saving File to File System through FTP 0 Not in the process Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 283 2015-08-03 1 During the process The data length received from FTP The data length saved in File System Response If it is a successful FTP get session: OKIf data transfer finished. +FTPGETTOFS: 0, If it is a failed FTP get session: OK +FTPGETTOFS:If error is related to ME functionality: +CME ERROR: Write Command AT+FTPGETTO FS=,[,,] Parameters file saved in ROM or SD card. 0 saved in ROM, file will be saved in "Disk1:\user\ftp" 1 saved in SD card, file will be saved in "Disk2:\ftp" Note: The local drive "Disk1" or SD drive "Disk2" can be got by AT+FSDRIVE. file name. Alphanumeric ASCII text string up to 64 characters Number of automatic reconnect times, from 0 to 255. Default value is 3. wait time before module start automatic reconnect, from 0 to 60 seconds. Default value is 5 seconds. The total length of data bytes have been saved 85 An error related with file system. Other errors please see FTPGET. Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note Automatic reconnection will start at break point. File will be overwritten if you start this function twice with a same file name. 12.2.25 AT+FTPPUTFRMFS Upload File from File System. AT+FTPPUTFRMFS Upload File from File System Test Command Response Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 284 2015-08-03 AT+FTPPUTFR MFS=? OK Response +FTPPUTFRMFS: [,] OK Read Command AT+FTPPUTFR MFS? Parameters the process status of uploading File from File System through FTP 0 not in the process 1 during the process the data length uploaded from File System Response If it is a successful FTP put session: OKIf data transfer finished. +FTPPUTFRMFS: 0, If it is a failed FTP put session: OK +FTPPUTFRMFS:If error is related to ME functionality: +CME ERROR: Write Command AT+FTPPUTFR MFS=[, ,] Parameters file path. Alphanumeric ASCII text string up to 128 characters Number of automatic reconnect times, from 0 to 255. Default value is 3. wait time before module start automatic reconnect, from 0 to 60 seconds. Default value is 5 seconds. the data length uploaded from File System 85 An error related with file system. Other errors pls see FTPGET. Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note Automatic reconnect will start at break point. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 285 2015-08-03 12.2.26 AT+FTPEXTGET Extend Download File AT+FTPEXTGET Extend Download File Test Command AT+FTPEXTGE T=? Response OK Response +FTPEXTGET: [,] OK Read Command AT+FTPEXTGE T? Parameters whether run FTPEXTGET or not 0 not run FTPEXTGET 1 run FTPEXTGET length module has received from FTP server Response If mode is 0 OK If it is a successful FTP get session in mode 1: OKIf data transfer finished in mode 1 +FTPEXTGET: 1,0 If it is a failed FTP get session in mode 1: OK +FTPEXTGET: 1, If mode is 2: +FTPEXTGET: 2, OK If mode is 3: +FTPEXTGET: 3, If error is related to ME functionality: +CME ERROR: Write Command 1)if mode is 0 or 1 AT+FTPEXTGE T= 2)if mode is 2 AT+FTPEXTGE T=, 3)if mode is 3 AT+FTPEXTGE T=,, Parameters 0 use default FTPGET method 1 start extend FTPGET method 2 save download data to filesystem Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 286 2015-08-03 3 output download data file name to write data in mode 2. Alphanumeric ASCII text string up to 64 characters. position start read data in mode 3. read length in mode 3 The total length of data bytes have been download total length will be output from serial port 85 An error related with file system. Other errors pls see FTPGET. Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note Can not use this function when set FTPEXTPUT mode 1 12.2.27 AT+FTPFILEPUT Load File in RAM from File System then Upolad with FTPPUT AT+FTPFILEPUT Load File in RAM from File System then Upload with FTPPUT Test Command AT+FTPFILEPU T=? Response OK Response If success: OK If error is related to ME functionality: +CME ERROR: Write Command AT+FTPFILEPU T=[,filena me] Parameters 0 not use FTPFILEPUT method 1 use FTPFILEPUT method file name to write data in mode 1. Alphanumeric ASCII text string up to 64 characters. 85 An error related with file system. Other errors pls see FTPGET. Parameter Saving Mode NO_SAVE Max Response Time 75 seconds(In case no response is received from server) Reference Note Can not use this function when set FTPEXTPUT mode 1. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 287 2015-08-03 12.2.28 AT+FTPQUIT Quit Current FTP Session AT+FTPQUIT Quit Current FTP Session Test Command AT+FTPQUIT=? Response OK Execution Command AT+FTPQUIT Response If success: OK If error is related to ME functionality: +CME ERROR: Parameter Saving Mode NO_SAVE Max Response TimeReference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 288 2015-08-03 13 AT Commands for GSM Location Application SIM800 series support GSM location operation. 13.1 Overview Command Description AT+CIPGSMLOC GSM location and time 13.2 Detailed Descriptions of Commands 13.2.1 AT+CIPGSMLOC GSM Location and Time AT+CIPGSMLOC GSM Location and Time Test Command AT+CIPGSMLOC= ? Response +CIPGSMLOC: (1,2),(1-3) OK Parameters See Write Command Response If =1: +CIPGSMLOC:[,,,,] OK If =2: +CIPGSMLOC:[,,] OK If error is related to ME functionality: +CME ERROR: Write Command AT+CIPGSMLOC= , Parameters 1 View the longitude, latitude and time 2 View time network parameters, refer to AT+SAPBR 0 Success If the operation failed, the location code is not 0, such as: 404 Not Found Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 289 2015-08-03 408 Request Time-out 601 Network Error 602 No memory 603 DNS Error 604 Stack Busy 65535 Other Error Current longitude in degrees Current latitude in degrees Format is YYYY/MM/DD, the time zone is GMT E.g. 2011/01/26 Format is hh/mm/ss,the time zone is GMT.E.g. 06:10:46 Parameter Saving Mode NO_SAVE Max Response Time 60 seconds Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 290 2015-08-03 14 AT Commands for Email ApplicationSIM800 series supports to send an Email with an attachment via SMTP protocol. It also supports carbon copy (abbreviated Cc:) recipient and blind carbon copy (abbreviated Bcc:) recipient.SIM800 series supports to retrieve and delete the Email via POP3 protocol, the Email may be with attachments.SIM800 series supports all of POP3 commands but APOP. By these POP3 commands, you can get the specific Email’s size and unique-id.SIM800 series does not support that SMTP and POP3 operations are executed at the same time. 14.1 Overview Command Description AT+EMAILCID Set Email bearer profile identifier AT+EMAILTO Set timeout value of SMTP/POP3 server response AT+SMTPSRV Set SMTP server address and port AT+SMTPAUTH Set user name and password for SMTP authentication AT+SMTPFROM Set sender address and name AT+SMTPRCPT Set the Email recipient(to/cc/bcc) address and name AT+SMTPSUB Set the Email subject AT+SMTPBODY Set the Email body AT+SMTPFILE Set the Email attachment AT+SMTPSEND Send the Email AT+SMTPFT Transfer the Email attachment AT+SMTPCS Set the Email charset AT+POP3SRV Set POP3 server and account AT+POP3IN Log in POP3 server AT+POP3NUM Get Email number and total size AT+POP3LIST Get the specific Email size AT+POP3UIDL Get the specific Email unique-id AT+POP3CMD Get multi-line response AT+POP3READ Read multi-line response AT+POP3DEL Mark the specific Email to delete AT+POP3RSET Unmark the emails that be marked as deleted AT+POP3OUT Log out POP3 server Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 291 2015-08-03 14.2 Detailed Descriptions of Commands 14.2.1 AT+EMAILCID Set Email Bearer Profile Identifier AT+EMAILCID Set Email Bearer Profile Identifier Response +EMAILCID: (range of supported s) OK Test Command AT+EMAILCID=? Parameters See Write Command Response +EMAILCID: OK Read Command AT+EMAILCID? Parameters See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+EMAILCID= Parameters bearer profile identifier refer to AT+SAPBR Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.2 AT+EMAILTO Set Timeout Value of SMTP/POP3 Server Response AT+EMAILTO Set Timeout Value of SMTP/POP3 Server Response Response +EMAILTO: (range of supported s) OK Test Command AT+EMAILTO=? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 292 2015-08-03 Response +EMAILTO: OK Read Command AT+EMAILTO? Parameters See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+EMAILTO= Parameters The timeout value of SMTP/POP3 server response, in 1 second unit. 10-120 Default: 30(seconds) Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.3 AT+SMTPSRV Set SMTP Server Address and Port AT+SMTPSRV Set SMTP Server Address and Port Response +SMTPSRV: ,(range of supported s) OK Test Command AT+SMTPSRV=? Parameters See Write Command Response +SMTPSRV: , OK Read Command AT+SMTPSRV? Parameter See Write Command Write Command AT+SMTPSRV= [,] Response OK If error is related to ME functionality: ERROR Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 293 2015-08-03 Parameters SMTP server address, string type. This parameter can be either:IP address in the format: xxx.xxx.xxx.xxxHost name to be solved with a DNS query The SMTP port 1-65535 Default: 25 The max length of Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.4 AT+SMTPAUTH Set User Name and Password for SMTP Authentication AT+SMTPAUTH Set User Name and Password for SMTP Authentication Response +SMTPAUTH: (range of supporteds),, OK Test Command AT+SMTPAUTH=? Parameters See Write Command Response +SMTPAUTH: ,, OK Read Command AT+SMTPAUTH? Parameters See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+SMTPAUTH=< authType>[,,] Parameters The type of SMTP authentication 0 SMTP server does not request authentication. and must not be given. 1 SMTP server requests authentication The user name for SMTP authentication. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 294 2015-08-03 The max length of . The password for SMTP authentication. The max length of . Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.5 AT+SMTPFROM Set Sender Address and Name AT+SMTPFROM Set Sender Address and Name Response +SMTPFROM: , OK Test Command AT+SMTPFROM= ? Parameters See Write Command Response +SMTPFROM: , OK Read Command AT+SMTPFROM? Parameter See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+SMTPFROM= [,] Parameters The Email sender address,string type. The max length of The Email sender name,string type. The max length of Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 295 2015-08-03 14.2.6 AT+SMTPRCPT Set the Email Recipient(TO/CC/BCC) Address and Name AT+SMTPRCPT Set the Email Recipient(TO/CC/BCC) Address and Name Response +SMTPRCPT: (range of supported s),(range of supported s),, OK Test Command AT+SMTPRCPT=? Parameters See Write Command Response [+SMTPRCPT: ,,, [+SMTPRCPT: ,,, […]]] OK Read Command AT+SMTPRCPT? Parameter See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+SMTPRCPT=< rcptType>[, [,[,]]] Parameters The type of recipient, the types of TO and CC are used to construct e-mail header in the field:”To:” or “Cc:”. 0 TO, Normal Recipient. 1 CC, Carbon Copy recipient. 2 BCC, Blind Carbon Copy recipient. Index of the type of recipient, decimal format The Email recipient address. The Email recipient name. The max length of . The max length of . Parameter Saving Mode NO_SAVE Max Response Time - Reference Note If only is given, it will delete all items of . If only and are given, it will delete the item of . Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 296 2015-08-03 14.2.7 AT+SMTPSUB Set the Email Subject AT+SMTPSUB Set the Email Subject Response +SMTPSUB: OK Test Command AT+SMTPSUB=? Parameters See Write Command Response +SMTPSUB: OK Read Command AT+SMTPSUB? Parameter See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+SMTPSUB= Parameters The Email subject, string type. It will be present in the header of the Email sent by SMTP client in the field: "Subject:" The max length of . Parameter Saving Mode NO_SAVE Max Response Time - Reference Note If the Email charset is not ASCII, must be in hexadecimal format. 14.2.8 AT+SMTPBODY Set the Email Body AT+SMTPBODY Set the Email Body Response +SMTPBODY: OK Test Command AT+SMTPBODY=? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 297 2015-08-03 Response DOWNLOAD OK If error is related to ME functionality: ERROR Write Command AT+SMTPBODY=< length> ,then type data as Email body. When body’s length equal length, command is over! Parameters The length of Email body. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note If the Email charset is not ASCII, the body of Email must be in hexadecimal format. After urc string "DOWNLOAD", User can input email’s body. 14.2.9 AT+SMTPFILE Set the Email Attachment AT+SMTPFILE Set the Email Attachment Response +SMTPFILE: (range of s),,(range of s) OK Test Command AT+SMTPFILE=? Parameters See Write Command Response +SMTPFILE: ,, OK Read Command AT+SMTPFILE? Parameter See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+SMTPFILE=[, ,] Parameters The type of the Email attachment. 0 no attachment 1 attach a txt file Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 298 2015-08-03 2 attach a binary file (bmp, mp3, video…) The name of the Email attachment. The max length of . Content-Transfer-Encoding used for attachment 0 "7bit" means data all represented as short lines of US-ASCII data 1 "base64" designed to represent arbitrary sequences of octets in a form that need not be humanly readable Parameter Saving Mode NO_SAVE Max Response Time - Reference Note If a txt file (=1) is attached, must be 0. If a binary file (=2) is attached, must be14.2.10 AT+SMTPSEND Send the Email AT+SMTPSEND Send the Email Response OK Test Command AT+SMTPSEND=? Parameters Response OK If error is related to ME functionality: ERROR If send successfully or not, return: +SMTPSEND: Execution Command AT+SMTPSEND Parameters The result of sending Email. 1 The Email has been sent successfully. 61 Network error. 62 DNS resolve error 63 SMTP TCP connection error. 64 Timeout of SMTP server response 65 SMTP server response error 66 Not authentication 67 Authentication failed. SMTP user name or password may be not right. 68 Bad recipient. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 299 2015-08-03 Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.11 AT+SMTPFT Transfer the Email Attachment AT+SMTPFT Transfer the Email Attachment Response OK Test Command AT+SMTPFT=? Parameters See Write Command Response When the URC below is reported, the attachment can be transferred: +SMTPFT: 1, If is not 0 and send data successfully: +SMTPFT: 2, ...... //Input data OK If is not 0 and send data unsuccessfully: +SMTPFT: 2, ...... //Input data ERROR If is 0,it indicates that transferring the attachment have finished: OK If error is related to ME functionality: ERROR If some error occur: +SMTPSEND: Write Command AT+SMTPFT= Parameters Requested number of data bytes(0-) to be transmitted Confirmed number of data bytes to be transmitted The max length of data can be sent at a time. It depends Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 300 2015-08-03 on the network status. See AT+SMTPSEND Parameter Saving Mode NO_SAVE Max Response Time - Reference Note can not be greater than . When “+SMTPFT: 1,” is reported, then use AT+SMTPFT= to send data. 14.2.12 AT+SMTPCS Set the Email Charset AT+SMTPCS Set the Email Charset Response +SMTPCS: OK Test Command AT+SMTPCS=? Parameters See Write Command Response +SMTPCS: OK Read Command AT+SMTPCS? Parameter See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+SMTPCS= Parameters The Email charset, string type. It shows which charset the subject and the body are encoded in. If is not ASCII but UTF-8 or other, the subject and the body must be in hexadecimal format (e.g. “TEST” should be converted to “54455354”). The default charset is ASCII. The max length of . Parameter Saving Mode NO_SAVE Max Response Time - Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 301 2015-08-03 Reference Note 14.2.13 AT+POP3SRV Set POP3 Server and Account AT+POP3SRV Set POP3 Server and Account Response +POP3SRV: ,,,(range of supported s) OK Test Command AT+POP3SRV=? Parameters See Write Command Response +POP3SRV: ,,, OK Read Command AT+POP3SRV? Parameters See Write Command Response OK If error is related to ME functionality: ERROR Write Command AT+POP3SRV=,,[,] Parameters POP3 server address, string type. This parameter can be either:IP address in the format: xxx.xxx.xxx.xxxHost name to be solved with a DNS query The user name to log in POP3 server, string type. The password to log in POP3 server, string type. The port of POP3 server. 1-65535 Default: 110 The max length of . The max length of . The max length of . Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 302 2015-08-03 14.2.14 AT+POP3IN Log in POP3 Server AT+POP3IN Log in POP3 Server Response OK Test Command AT+POP3IN=? Parameters Response OK If error is related to ME functionality: ERROR If logging in POP3 server or not, return: +POP3IN: Execution Command AT+POP3IN Parameters The result of logging in POP3 server 1 Log in POP3 server successfully 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response 65 POP3 server response error 66 POP3 server rejects to log in 67 Incorrect user name 68 Incorrect user name or password 69 Timeout of read data Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.15 AT+POP3NUM Get Email Number and Total Size AT+POP3NUM Get Email Number and Total Size Response OK Test Command AT+POP3NUM=? Parameter Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 303 2015-08-03 Response OK If error is related to ME functionality: ERROR If POP3 server issues a positive response: +POP3NUM: 1,, If POP3 server issues a negative response: +POP3NUM: 0 If some error occur: +POP3OUT: Execution Command AT+POP3NUM Parameters The Email number on the POP3 server, decimal format. The total size of all Email and the unit is in byte. The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.16 AT+POP3LIST Get the Specific Email Size AT+POP3LIST Get the Specific Email Size Response +POP3LIST: (range of supported s) OK Test Command AT+POP3LIST=? Parameter See Write Command Write Command AT+POP3LIST= Response OK If error is related to ME functionality: ERROR If POP3 server issues a positive response: +POP3LIST: 1,, If POP3 server issues a negative response: +POP3LIST: 0 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 304 2015-08-03 If some error occur: +POP3OUT: Parameters The message number of Email. The size of Email and the unit is in byte. The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.17 AT+POP3UIDL Get the Specific Email Unique-id AT+POP3UIDL Get the Specific Email Unique-id Response +POP3UIDL: (range of supported s) OK Test Command AT+POP3UIDL=? Parameters See Write Command Response OK If error is related to ME functionality: ERROR If POP3 server issues a positive response: +POP3UIDL: 1,, If POP3 server issues a negative response: +POP3UIDL: 0 If some error occur: +POP3OUT: Write Command AT+POP3UIDL=< msgNumber> Parameters The message number of Email . The Email unique-id, the unique-id is an arbitrary Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 305 2015-08-03 server-determined string, consisting of 1 to 70 characters in the range 0x21 to 0x7E, which uniquely identifies a message within a maildrop and which persists across sessions. The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 14.2.18 AT+POP3CMD Get Multi-line Response AT+POP3CMD Get Multi-line Response Response +POP3CMD: (range of supported s),(range of supporte ds),(range of supported s) OK Test Command AT+POP3CMD=? Parameters See Write Command Response OK If error is related to ME functionality: ERROR If POP3 server issues a positive response: +POP3CMD: 1 If POP3 server issues a negative response: +POP3CMD: 0 If some error occur: +POP3OUT: Write Command AT+POP3CMD=[,[,lineNumber]] Parameters The values that supported POP3 user command 1 List command The “List” command returns a multi-line “scan listing”. For each message on the maildrop list of the server the POP3 service returns a line containing the message number and its size in bytes. A final “dotline” will be printed at the end of the “scan listing“. If there are no messages on the maildrop list of the server, the POP3 service returns a positive response, i.e. It Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 306 2015-08-03 does not issue an error response, but the “scan listing” will be empty. In either case, each scan listing will be finished by so-called “dotline”, i.e. a new line with just a single dot. and must not be given. 2 Uidl command The “Uidl” command returns a multi-line “unique-id Listing”. For each message on the maildrop list of the Server the POP3 service returns a line containing the message number and its unique-id. A final “dotline” will be printed at the end of the “unique-id listing” If there are no messages on the maildrop list of the server. The POP3 service returns a positive response, i.e. It does not issue an error response, but the “uniqueid listing” will be empty. In either case, each unique-id listing will be finished by so-called “dotline”, i.e.a new line with just a singledot. and must not be given. 3 Top command The command retrieves the number of lines of the message’s body from the POP3 server’s maildrop list. The POP3 server sends the headers of the message, the blank line separating the headers from the body, and then the number of lines of the message’s body. If the number of lines requested by The POP3 client is greater than the number of lines in the body, then the POP3 server sends the entire message. If no such message exists on the server the POP3 service issues an error response to the user. Each email will be finished by a so-called “dotline”, i.e.a new line with just a single dot. and must be given. 4 Retrieve command The command retrieves the related message from the POP3 server’s maildrop list. If no such message exists on the server the POP3 service issues an error response to the user. Each email will be finished by a so-called “dotline”, i.e. a new line with just a single dot. must be given. The message number of Email. The number of lines of the message body. The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 307 2015-08-03 64 Timeout of POP3 server response Parameter Saving Mode NO_SAVE Max Response Time - Reference Note After sending these POP3 commands and POP3 server issuing a positive response, you can get the response by AT+POP3READ. 14.2.19 AT+POP3READ Read Multi-line Response AT+POP3READ Read Multi-line Response Response +POP3READ: (range of supported s) OK Test Command AT+POP3READ=? Parameters See Write Command Response If the data of response not to be read completely: +POP3READ: 1, If the data of response to be read completely: +POP3READ: 2, If some data need to be read,the URC below is reported: +POP3READ: 3, If error is related to ME functionality: ERROR If some error occur: +POP3OUT: Write Command AT+POP3READ=< reqLength> Parameters Requested number of data bytes (1-1460) to be read Confirmed number of data bytes to be read, which may be less than . 0 indicates that no data can be read. Received number of data bytes. The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response 69 Read data timeout Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 308 2015-08-03 Mode Max Response Time - Reference Note Other AT commands (but AT+POP3OUT) can not be executed until the data of response are read completely. If is less than , you should wait for a URC “+POP3READ: 3,” reported. Then you may continue to read data by AT+POP3READ. If the module has some unread data, the URC “+POP3READ: 3,” is reported every once in a while. After so me time, these data are not still read, the module will quit th e POP3 process. 14.2.20 AT+POP3DEL Mark the Specific Email to Delete AT+POP3DEL Mark the Specific Email to Delete Response +POP3DEL: (range of supported s) OK Test Command AT+POP3DEL=? Parameters See Write Command Response OK If error is related to ME functionality: ERROR If POP3 server issues a positive response: +POP3DEL: 1 If POP3 server issues a negative response: +POP3DEL: 0 If some error occur: +POP3OUT: Write Command AT+POP3DEL= Parameters The message number of Email The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 309 2015-08-03 Max Response Time - Reference Note The POP3 server marks the Email as deleted. Any future reference to the message-number associated with the Email in a POP3 command generates an error. The POP3 server does not actually delete the Email until the POP3 client logs out POP3 server and closes the session normally. 14.2.21 AT+POP3RSET Unmark the Emails that Be Marked as Deleted AT+POP3RSET Unmark the Emails that Be Marked as Deleted Response OK Test Command AT+POP3RSET=? Parameter Response OK If error is related to ME functionality: ERROR If POP3 server issues a positive response: +POP3RSET: 1 If POP3 server issues a negative response: +POP3REST: 0 If some error occur: +POP3OUT: Execution Command AT+POP3RSET Parameters The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 310 2015-08-03 14.2.22 AT+POP3OUT Log Out POP3 Server AT+POP3OUT Log Out POP3 Server Response OK Test Command AT+POP3OUT=? Parameters Response OK If error is related to ME functionality: ERROR If the process is completed, return: +POP3OUT: Execution Command AT+POP3OUT Parameters The result of logging out POP3 server 1 Normally log out POP3 server 61 Network error 62 DNS resolve error 63 POP3 tcp connection error 64 Timeout of POP3 server response 69 Timeout of read data Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 311 2015-08-03 15 AT Commands for MMS Application SIM800 series support MMS operation. 15.1 Overview Command Description AT+CMMSCURL Set the URL of the MMS center AT+CMMSPROTO Set the protocol parameter and MMS proxy AT+CMMSCID Set the network parameters for MMS AT+CMMSSENDCFG Set the parameters for sending MMS AT+CMMSEDIT Enter or exit edit mode AT+CMMSDOWN Download the file data or title from UART AT+CMMSDELFILE Delete the file of the edited MMS by file index AT+CMMSSEND Start MMS sending AT+CMMSRECP Add recipients AT+CMMSCC Add copy recipients AT+CMMSBCC Add secret recipients AT+CMMSDELRECP Delete recipients AT+CMMSDELCC Delete copy recipients AT+CMMSDELBCC Delete secret recipients AT+CMMSRECV Receive MMS AT+CMMSVIEW Get the MMS into buffer and show the information AT+CMMSREAD Read the given file of the MMS in the buffer AT+CMMSRDPUSH Read the information of the MMS push message AT+CMMSUA Set User Agent AT+CMMSPROFILE Set User Agent Profile AT+CMMSTIMEOUT Set MMS Timeout AT+CMMSSTATUS Get MMS Status AT+CMMSINIT Initialize MMS Function AT+CMMSTERM Exit MMS function AT+CMMSSCONT Save MMS context Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 312 2015-08-03 15.2 Detailed Descriptions of Commands 15.2.1 AT+CMMSCURL Set the URL of the MMS Center AT+CMMSCURL Set the URL of the MMS Center Test Command AT+CMMSCURL= ? Response +CMMSCURL: “URL” OK Parameters See Write Command Response +CMMSCURL: OK Read Command AT+CMMSCURL? Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSCURL=Parameters The URL of the MMS center. Parameter Saving Mode AT+CMMSSCONT Max Response Time - Reference Note 15.2.2 AT+CMMSPROTO Set the Protocol Parameter and MMS Proxy AT+CMMSPROTO Set the Protocol Parameter and MMS Proxy Response +CMMSPROTO: “(0-255).(0-255).(0-255).(0-255)”,(1-65535) OK Test Command AT+CMMSPROTO =? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 313 2015-08-03 Response +CMMSPROTO: , OK Read Command AT+CMMSPROTO ? Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSPROTO =,<PortParameters IP address of MMS proxy. Port of MMS proxy. Parameter Saving Mode AT+CMMSSCONT Max Response Time - Reference Note 15.2.3 AT+CMMSCID Set the Network Parameters for MMS AT+CMMSCID Set the Network Parameters for MMS Response +CMMSCID: (1-3) OK Test Command AT+CMMSCID=? Parameters See Write Command Response +CMMSCID: OK Read Command AT+CMMSCID? Parameters See Write Command Write Command AT+CMMSCID= Response OK or ERROR or Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 314 2015-08-03 +CME ERROR: Parameters network parameters, refer to AT+SAPBR Parameter Saving Mode AT+CMMSSCONT Max Response Time - Reference Note 15.2.4 AT+CMMSSENDCFG Set the Parameters for Sending MMS AT+CMMSSENDCFG Set the Parameters for Sending MMS Response +CMMSSENDCFG: (0-6), (0-3),(0,1), (0,1),(0-2),(0-4),(1-2),(0,1) OK Test Command AT+CMMSSENDC FG=? Parameters See Write Command Response +CMMSSENDCFG: ,,,,,,, OK Read Command AT+CMMSSENDC FG? Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSSENDC FG=[,[ ,[,[,[,<class[,[,]]]]]]] Parameters The valid time of sent MMS 0 1 hour 1 12 hours 2 24 hours 3 2 days 4 1 week 5 maximum Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 315 2015-08-03 6 Not set (default) Priority 0 lowest 1 normal 2 highest 3 Not Set (default) Whether it need deliver report 0 No (default) 1 Yes Whether it need receive report 0 No (default) 1 Yes Whether it need show the sender address 0 hide the sender address 1 show the sender address even if it is a secret address 2 Not set (default) The class of the MMS 0 Personal 1 Advertisement 2 Informational 3 Auto 4 Not set (default) Subject control 1 For Chinese character code 2 For English character code Whether it need to check the HTTP response of MMS notifyrsp ind then to proceed the next step. 0 Waiting for HTTP response 1 Skip waiting for HTTP response Parameter Saving Mode AT+CMMSSCONT Max Response Time - Reference Note 15.2.5 AT+CMMSEDIT Enter or Exit Edit Mode AT+CMMSEDIT Enter or Exit Edit Mode Test Command AT+CMMSEDIT=? Response +CMMSEDIT: (0,1) OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 316 2015-08-03 Parameters See Write Command Response +CMMSEDIT: OK Read Command AT+CMMSEDIT? Parameters See Write Command Write Command AT+CMMSEDIT=< mode> Response OK or ERROR or +CME ERROR: Parameters Whether it allows to edit MMS 0 Not allow to edit MMS 1 Allow to edit MMS Parameter Saving Mode NO_SAVE Max Response Time - Reference Note It includes adding and deleting receipt, downloading and deleting files, downloading title to edit MMS. 15.2.6 AT+CMMSDOWN Download the File Data or Title from UART AT+CMMSDOWN Download the File Data or Title from UART Test Command AT+CMMSDOWN =? Response +CMMSDOWN: "PIC", (1-307200), (5000-),"NAME" +CMMSDOWN: "TEXT", (1-15360), (2000-),"NAME" +CMMSDOWN: "TITLE", (1-40), (2000-) +CMMSDOWN: "AUDIO_ACC", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_AMR", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_BASIC", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_MID", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_MPEG", (1-307200), (5000-),"NAME" +CMMSDOWN: "VIDEO_3GPP", (1-307200), (5000-),"NAME" +CMMSDOWN: " VIDEO _MP4", (1-307200), (5000-),"NAME" OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 317 2015-08-03 Response CONNECT or ERROR or +CME ERROR: Write Command AT+CMMSDOWN =,,[,] Parameters A string parameter which indicates type of downloaded data "TITLE" MMS title data "TEXT" MMS text data "PIC" MMS image data "AUDIO_AAC" MMS aac audio data "AUDIO_AMR" MMS amr audio data "AUDIO_BASIC" MMS basic audio data "AUDIO_MID" MMS mid audio data "AUDIO_MPEG" MMS mpeg audio data "VIDEO_3GPP" MMS 3gpp video data "VIDEO_MP4" MMS mp4 video data Size in bytes of the data to be downloaded. Maximum time in milliseconds to download data. The file name of the image or the text to be downloaded, including extended name. The default name for image is "image.jpg" and the default name for text is "text.txt". and are in the range of 0~255 Parameter Saving Mode NO_SAVE Max Response Time Decided by Reference Note It is strongly recommended to set the time long enough to download all the file data and make sure that the real size of the file to download is not bigger than . The maximum size of is 40 Bytes and only ASCII code is recognized for . 15.2.7 AT+CMMSDELFILE Delete the File of the Edited MMS by File Index AT+CMMSDELFILE Delete the File of the Edited MMS by File Index Test Command AT+CMMSDELFI LE=? Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 318 2015-08-03 Response OK or ERROR or +CME ERROR: Write Command AT+CMMSDELFI LE= Parameters The index of the file to be deleted in the MMS. Refer to "+CMMSVIEW" Parameter Saving Mode NO_SAVE Max Response Time - Reference Note This command is valid when it is allowed to edit MMS 15.2.8 AT+CMMSSEND Start MMS Sending AT+CMMSSEND Start MMS Sending Test Command AT+CMMSSEND= ? Response +CMMSSEND: "ADDRESS" OK Response OK or ERROR or +CME ERROR: Write Command AT+CMMSSEND=Parametersa string parameter which indicates address of recipients. Execution Command AT+CMMSSEND Response OK or ERROR or +CME ERROR: Parameter Saving Mode NO_SAVE Max Response Time AT+CMMSTIMEOUT Reference Note It is not allowed to inputwhen it not allowed to edit MMS Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 319 2015-08-03 15.2.9 AT+CMMSRECP Add Recipients AT+CMMSRECP Add Recipients Test Command AT+CMMSRECP= ? Response +CMMSRECP: "ADDRESS" OK Response +CMMSRECP: the list of s OK Read Command AT+CMMSRECP? Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSRECP= Parameters a string parameter which indicates phone number or email address of recipients. The maximum length of the string is 40. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note The maximum of recipients is 20 and this command is valid only when it is allowed to edit MMS 15.2.10 AT+CMMSCC Add Copy Recipients AT+CMMSCC Add Copy Recipients Test Command AT+CMMSCC=? Response +CMMSCC: "ADDRESS" OK Read Command AT+CMMSCC? Response +CMMSCC: the list of s OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 320 2015-08-03 Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSCC= Parameters a string parameter which indicates phone number or email address of copy recipients. The maximum length of the string is 40. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note The maximum of copy recipients is 20 and this command is valid only when it is not allowed to edit MMS 15.2.11 AT+CMMSBCC Add Secret Recipients AT+CMMSBCC Add Secret Recipients Test Command AT+CMMSBCC=? Response +CMMSBCC: "ADDRESS" OK Response +CMMSBCC: the list of s OK Read Command AT+CMMSBCC? Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSBCC=< addr> Parameters a string parameter which indicates phone number or email address of secret recipients. The maximum length of the Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 321 2015-08-03 string is 40. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note The maximum of secret recipients is 20 and this command is valid only when it is allowed to edit MMS 15.2.12 AT+CMMSDELRECP Delete Recipients AT+CMMSDELRECP Delete Recipients Test Command AT+CMMSDELRE CP=? Response +CMMSDELRECP: "ADDRESS" OK Response OK or ERROR or +CME ERROR: Write Command AT+CMMSDELRE CP= Parameters a string parameter which indicates phone number or email address of recipient. The maximum length of the string is 40. Execution Command AT+CMMSDELRE CP Delete all the recipients Response OK Parameter Saving Mode NO_SAVE Max Response Time - Reference Note This command is valid when it is allowed to edit MMS 15.2.13 AT+CMMSDELCC Delete Copy Recipients AT+CMMSDELCC Delete Copy Recipients Test Command AT+CMMSDELCC Response +CMMSDELCC: "ADDRESS" Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 322 2015-08-03 =? OK Response OK or ERROR or +CME ERROR: Write Command AT+CMMSDELCC = Parameters a string parameter which indicates phone number or email address of copy recipients. The maximum length of the string is 40. Execution Command AT+CMMSDELCC Delete all the copy recipients Response OK Parameter Saving Mode NO_SAVE Max Response Time - Reference Note This command is valid when it is allowed to edit MMS 15.2.14 AT+CMMSDELBCC Delete Secret Recipients AT+CMMSDELBCC Delete Secret Recipients Test Command AT+CMMSDELBC C=? Response +CMMSDELBCC: "ADDRESS" OK Response OK or ERROR or +CME ERROR: Write Command AT+CMMSDELBC C= Parameters a string parameter which indicates phone number or email address of secret recipient. The maximum length of the string is 40. Execution Command AT+CMMSDELBC C Delete all the secret recipients Response OK Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 323 2015-08-03 Mode Max Response Time - Reference Note This command is valid when it is allowed to edit MMS 15.2.15 AT+CMMSRECV Receive MMS AT+CMMSRECV Receive MMS Test Command AT+CMMSRECV= ? Response +CMMSRECV: (range of ) OK Response +CMMSRECV: "","","", list of OK or ERROR or +CME ERROR: Write Command AT+CMMSRECV= Parameters The index of the push message saved in the SIM message box. The address of the sender The time to receive the MMS the title of the MMS The size of the MMS The index, name and size of every file included in the MMS. The types are defined as following. 2 text 3 text/html 4 text/plain 5 image 6 image/gif 7 image/jpg 8 image/tif 9 image/png 10 smil Parameter Saving Mode NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 324 2015-08-03 Max Response Time AT+CMMSTIMEOUT Reference Note This command is valid only when it is not allowed to edit MMS and the buffer for MMS will be clear up. So it is recommended to save the MMS in the buffer before receiving MMS. The received MMS is just saved in the buffer but not saved in the flash. The maximum number of inclosure is 10. 15.2.16 AT+CMMSVIEW Get the MMS into Buffer and Show the Information AT+CMMSVIEW Get the MMS into Buffer and Show the Information Test Command AT+CMMSVIEW= ? Response OK Response +CMMSVIEW: ,"", "", "", "", "","",list of OK or ERROR or +CME ERROR: Execution Command AT+CMMSVIEW Parameters The type of MMS 0 Received MMS 1 Sent MMS 2 Unsent MMS The address of th sender List of recipients, Separated by “;” List of copy recipients , Separated by “;” List of secret recipients , Separated by “;” The time of receive MMS The title of MMS Data size of MMS The index, name and size of every file included in the MMS. The types are defined as following. 2 text 3 text/html 4 text/plain 5 image Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 325 2015-08-03 6 image/gif 7 image/jpg 8 image/tif 9 image/png 10 smil Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 15.2.17 AT+CMMSREAD Read the Given File of the MMS in the Buffer AT+CMMSREAD Read the Given File of the MMS in the Buffer Test Command AT+CMMSREAD= ? Response OK Response +CMMSREAD: File content OK Write Command AT+CMMSREAD= Parameters the index of the file to be read from the MMS in the buffer,i.e. the parameter in “AT+CMMSRECV” and “AT+CMMSVIEW” the file name to be read the size of the file to be read Parameter Saving Mode NO_SAVE Max Response Time 5s Reference Note If the file type is text, the character set of the output text is Unicode little endian without the header “FF FE”. 15.2.18 AT+CMMSRDPUSH Read the Information of the MMS PUSH Message AT+CMMSRDPUSH Read the Information of the MMS PUSH Message Test Command AT+CMMSRDPUS Response +CMMSRDPUSH: (range of ) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 326 2015-08-03 H=? OK Response +CMMSRDPUSH: 2,””,””,””,””,””,< class>, OK or +CMMSRDPUSH: 6, “”,””, OK or +CMMSRDPUSH: 255 OK or +CME ERROR: Write Command AT+CMMSRDPUS H= Parameters The first parameter of the response should be 2 or 6, or the other type of the MMS PDU. 2 m-notification-ind[2]. To inform the contents of a received MMS 6 m-delivery-ind[2]. A delivery report 255 unknown MMS PDU The index of the push message saved in the SIM message box. The address of the sender The address of the receiver The title of the MMS The X-Mms-Transation-ID[2] of the received MMS The X-Mms-Content-Location[2] of the received MMS The X-Mms-Class[2] of the received MMS 0 Personal 1 Advertisement 2 Informational 3 Auto Date and time of the received push message. The size of the MMS The status of the sent MMS 0 Expired 1 Retrieved 2 Rejected 3 Defered Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 327 2015-08-03 4 Unrecognized Parameter Saving Mode NO_SAVE Max Response Time 5s Reference Note This command is valid only when it is not allowed to edit MMS and the buffer for MMS will be clear up. So it is recommended to save the MMS in the buffer before receiving MMS. The received MMS is just saved in the buffer but not saved in the flash. 15.2.19 AT+CMMSUA Set User Agent AT+CMMSUA Set User Agent Response +CMMSUA: "UserAgent" OK Test Command AT+CMMSUA=? Parameters See Write Command Response +CMMSUA: OK Read Command AT+CMMSUA? Parameter See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSUA= Parameters string type user agent name Parameter Saving Mode AT+CMMSSCONT Max Response Time - Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 328 2015-08-03 15.2.20 AT+CMMSPROFILE Set User Agent Profile AT+CMMSPROFILE Set User Agent Profile Response +CMMSPROFILE: "UserAgentProfile" OK Test Command AT+CMMSPROFI LE=? Parameters See Write Command Response +CMMSPROFILE: OK Read Command AT+CMMSPROFI LE? Parameter See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSPROFI LE= Parameters string type user agent profile Parameter Saving Mode AT+CMMSSCONT Max Response Time - Reference Note 15.2.21 AT+CMMSTIMEOUT Set MMS Timeout AT+CMMSTIMEOUT Set MMS Timeout Response +CMMSTIMEOUT: (10-1000),(10-1000) OK Test Command AT+CMMSTIMEO UT=? Parameters See Write Command Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 329 2015-08-03 Response +CMMSTIMEOUT: , OK Read Command AT+CMMSTIMEO UT? Parameters See Write Command Response OK or ERROR or +CME ERROR: Write Command AT+CMMSTIMEO UT=,> Parameters Send timeout time, integer type, in seconds. Receive timeout time, integer type, in seconds. Parameter Saving Mode AT+CMMSSCONT Max Response Time - Reference Note 15.2.22 AT+CMMSSTATUS Get MMS Status AT+CMMSSTATUS Get MMS Status Response OK Test Command AT+CMMSSTATU S=? Parameters See Write Command Response +CMMSSTATUS: OK or ERROR or +CME ERROR: Read Command AT+CMMSSTATU S? Parameters status of MMS action MMS_IDLE MMS_DOWNLOADING MMS_DOWNLOADED Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 330 2015-08-03 MMS_SENDING MMS_RECEIVING MMS_RECEIVED MMS_READING MMS_READING_PUSH Parameter Saving Mode NO_SAVE Max Response Time - Reference Note 15.2.23 AT+CMMSINIT Initialize MMS Function AT+CMMSINIT Initialize MMS Function Response OK Test Command AT+CMMSINIT=? Parameters No Parameter Response OK or ERROR or +CME ERROR: Execution Command AT+CMMSINIT No Parameter Parameter Saving Mode NO_SAVE Max Response Time - Reference Note When first entering the MMS function, this command must be executed. 15.2.24 AT+CMMSTERM Exit MMS Function AT+CMMSTERM Exit MMS Function Test Command AT+CMMSTERM= ? Response OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 331 2015-08-03 Parameters No Parameter Response OK or ERROR or +CME ERROR: Execution Command AT+CMMSTERM No Parameter Parameter Saving Mode NO_SAVE Max Response Time - Reference Note When exiting the MMS function, this command must be executed. 15.2.25 AT+CMMSSCONT Save MMS Context AT+CMMSSCONT Save MMS Context Response OK Test Command AT+CMMSSCONT =? Parameters See Execution Command Response +CMMSSCONT: +CMMSCID: +CMMSCURL: +CMMSUA: +CMMSPROFILE: +CMMSPROTO: , +CMMSSENDCFG:,,,,,< class>,, +CMMSTIMEOUT: , OK Read Command AT+CMMSSCONT ? Parameters See Execution Command Response OK Execution Command AT+CMMSSCONT Parameters Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 332 2015-08-03 0 saved, the value from NVRAM For other parameters, see the related command. Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 333 2015-08-03 16 AT Commands for DDET Application DTMF detection can be set or activated by DDET command. 16.1 Overview Command Description AT+DDET DTMF detection control 16.2 Detailed Descriptions of Commands 16.2.1 AT+DDET DTMF Detection Control AT+DDET DTMF Detection Control Response +DDET: (0,1),(0-10000),(0,1),(0,1) OK Test Command AT+DDET=? Parameters See Write Command Response +DDET: ,,, OK Read Command AT+DDET? Parameters See Write Command Response OK ERROR Write Command AT+DDET=[,][ ,][ ,] Unsolicited Result Code 1)If is set to 0 +DTMF: 2)If is set to 1 +DTMF: , Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 334 2015-08-03 Parameters disable or enable DTMF detection control 0 disable 1 enable the min interval between two same key URC. The range is 0-10000, the default value is 0. unit is ms. URC report mode 0 key value reported only 1 key value and last time are reported, the last time is in ms keytone detected, 1-9,*,#,A,B,C,D.if is 1,Single frequency sound 1400 and 2300 is supported too, when single frequency 1400HZ sound or 2300HZ sound is detected, +DTMF:1400 or +DTMF:2300 is reported duration of keytone playing. unit is ms. single frequency sound detect function on off 0 switch off 1 switch on Parameter Saving Mode AT&W_SAVE Max Response Time - Reference Note The parameters , and can not power off save Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 335 2015-08-03 17 AT Commands for RECORD Application 17.1 Overview Command Description AT+CREC Record operation AT+CRECORD Record and send data to UART 17.2 Detailed Descriptions of Commands 17.2.1 AT+CREC Record Operation AT+CREC Record Operation Response +CREC: (1-n),(1-10) OK Test Command AT+CREC=? Parameters See Write Command Response +CREC: OK Read Command AT+CREC? Parameters 0 idle state 1 recording state 2 playing state Write Command AT+CREC=,[] Response OK 1) mode=1,start record AT+CREC=1,,,[][,],[],[] OK 2) mode=2,stop record AT+CREC=2 OK +CREC: 2,,,, Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 336 2015-08-03 3) mode=3,delete record AT+CREC=3, OK 4) mode=4,play record file AT+CREC=4,,,[,] OK 5) mode=5,stop play record file AT+CREC=5 +CREC: 0 OK 6) mode=6,read record data AT+CREC=6,,, +CREC: 6,, OK 7) mode=7,view record file infomation AT+CREC=7,[] +CREC: 7,,, OK 8) mode=8,query free space for recording If SD card is supported AT+CREC=8 +CREC: 8,sys: sd: OK If SD card is not supported AT+CREC=8 +CREC: 8, OK 9) mode=9, create record file directory. AT+CREC=9, OKIf error is related to ME functionality: +CME ERROR: 5000 Be recoding 5001 Be playing 5002 Audio busy 5003 No space Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 337 2015-08-03 5004 Format error 5005 File operation failure 5006 File is null 5007 File size is error 5008 File is not exist Parameters number of operation support, if SD card is supported, the number will be 9, or will be 8 1 start record 2 stop record 3 delete record 4 play record 5 stop play record 6 get record data in hex format, the max length is 32K in bytes 7 list record files infomation 8 query free space in bytes 9 create record file direcotry file ID number, 1-10 or file path with double quotation marks, such as "C:\User\1155165.amr".record file format 0 AMR 1 WAV 2 WAV_ADPCM recording time limit. The recording will be stopped if the recording time reaches the time limit, or there is a mistake/ memory full/other events disturbed (call setup, etc.)/ Or manual operation.If 0 or default value is set, no time limit is set. channel 0 main channel 1 aux channel 0-100, play volume repeate 0 play once 1 play infinitely length in bytes. When read record data, the max length is 32K offset of the record file , it is less than the length of reord file. When read the record file, if the len+offset is larger than the file length, then we need to return to the actural data length. record file data in hex format record file location 0 system FAT 1 SD card input channel 0 MIC1 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 338 2015-08-03 1 MIC2 record quality 0 low 1 medium 2 high 3 best Parameter Saving Mode NO_SAVE Max Response Time - Reference Note Record will overwrite the record file with the same ID when free space is enough,but overwrite the record file with the same ID and format when free space is not enough. About 40K FAT space will remain for system use. The setting of input path doesn’t take effect when record in call. Play in call support low quality WAV record file. Location relative setting only take effect when SD card is support and plugged in. When DDET is set to 1, record is not allowed in call. The value of parameter of AT+CREC=7 can not support file path. The value of parameter of AT+CREC=1 is invalid if the value of is file path. The record file format can get from file path. The max length of parameter of AT+CREC=6 is 32K bytes. Scope of parameter is different among SIM800 series project, please refer to chapter 21 for details. 17.2.2 AT+CRECORD Record and Send Data to UART AT+CRECORD Record and Send Data to UART Response +CRECORD: (0,1) OK Test Command AT+CRECORD =? Parameters See Write Command Write Command AT+CRECORD =[,][,] Response OK or +CRECORD: or ERROR Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 339 2015-08-03 Parameters UART data output in specified form, which is deciede by 0 stop record 1 start record UART data output interval, the range is 1-50, the default value is 50. unit is 20ms. data form 0 UART data is the audio data 1 0x7E is added to the head, 0x7E is converted to 0x7D 0x5E, 0x7D is converted to 0x7D 0x5D. 2 0x7E is added to the head, 0x7E is converted to 0x7D 0x5E, 0x7D is converted to 0x7D 0x5D,a 2byte CRC code is added to the end Parameter Saving Mode NO_SAVE Max Response Time - Reference Note When AT+CRECORD is set to 1, data mode will be entered and audio data will output on the UART every the interval time, any input on the UART will stop the record. AT+CRECORD=0 take no effect. AMR 4.75K is supported only AMR file head “#*AMR\n” is not outputed Note: Part of the projects support record function, please refer to chapter 21 for details. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 340 2015-08-03 18 AT Commands for TTS Application 18.1 Overview Command Description AT+CTTS TTS operation AT+CTTSPARAM Set params of the TTS playing AT+CTTSRING Enable/disable TTS play during incoming call ring 18.2 Detailed Descriptions of Commands 18.2.1 AT+CTTS TTS Operation AT+CTTS TTS Operation Response OK Test Command AT+CTTS=? No prameter Response +CTTS: OK Read Command AT+CTTS? Parameters 0 idle mode 1 play mode Response if=0,response: OK if=1 or 2,response: OK +CTTS: 0 // speech played overIf error is related to MS functionality, response: +CME ERROR: Write Command AT+CTTS=[,] Parameters 0 Stop playing speech 1 Start to play synthetic speech, is in UCS2 coding format. 2 Start to play synthetic speech, is in ASCII coding format. Chinese text is in GBK coding format. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 341 2015-08-03 The text which is synthetized to speech to be played, maximum data length is 956 Bytes Parameter Saving Mode NO_SAVE Max Response TimeReference Note Call setup will stop the current tts play TTS can play in call, but call release will stop the tts play TTS play is not allowed when alert or ring 18.2.2 AT+CTTSPARAM Set Parameters of the TTS Playing AT+CTTSPARAM Set Parameters of the TTS Playing Response +CTTSPARAM: (0-100),(0-3),(1-100),(1-100),(0,1) OK Test Command AT+CTTSPARAM= ? Parameters See Write Command Response +CTTSPARAM: ,,,, OK Read Command AT+CTTSPARAM? Parameters See Write Command Response OK If error is related to MS functionality, response: +CME ERROR: Write Command AT+CTTSPARAM= ,, ,[,] Parameters TTS playing volume, the range is 0-100,the default is 50. TTS playing mode, the range is 0-3 0 auto read digit, and read digit based on number rule first 1 auto read digit, and read digit based on telegram rule first 2 read digit based on telegram rule 3 read digit based on number rule TTS playing pitch, the range is 1-100,the default is 50. TTS playing speed, the range is 1-100,the default is 50. TTS play channel. 0 main channel 1 aux channel Parameter Saving NO_SAVE Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 342 2015-08-03 Mode Max Response Time - Reference Note TTS play channel setting take no effect in call. TTS play channel depend on CHFA when in call. The default value of parameter is different among SIM800 series projects, please refer to chapter 21 for details. 18.2.3 AT+CTTSRING Enable/Disable TTS Play During Incoming Call Ring AT+CTTSRING Enable/Disable TTS Play During Incoming Call Ring Response +CTTSRING: (0,1) OK Test Command AT+CTTSRING=? Parameters See Write Command Response +CTTSRING: OK Read Command AT+CTTSRING? Parameters See Write Command Response OK If error is related to MS functionality, response: +CME ERROR: Write Command AT+CTTSRING=< mode> Parameters enable/disable TTS play during incoming call ring 0 diable TTS play during incoming call ring 1 enable TTS play during incoming call ring Parameter Saving Mode NO_SAVE Max Response Time - Reference Note If is set to 1, it is up to the customer to stop TTS play before accept the call Note: Part of the project supported TTS function, please refer to chapter 21 for details. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 343 2015-08-03 19 Supported Unsolicited Result Codes 19.1 Summary of CME ERROR Codes Final result code +CME ERROR: indicates an error related to mobile equipment or network. The operation is similar to ERROR result code. None of the following commands in the same Command line is executed. Neither ERROR nor OK result code shall be returned. values used by common messaging commands: Code of Meaning 0 phone failure 1 no connection to phone 2 phone-adaptor link reserved 3 operation not allowed 4 operation not supported 5 PH-SIM PIN required 6 PH-FSIM PIN required 7 PH-FSIM PUK required 10 SIM not inserted 11 SIM PIN required 12 SIM PUK required 13 SIM failure 14 SIM busy 15 SIM wrong 16 incorrect password 17 SIM PIN2 required 18 SIM PUK2 required 20 memory full 21 invalid index 22 not found 23 memory failure 24 text string too long 25 invalid characters in text string 26 dial string too long 27 invalid characters in dial string 30 no network service 31 network timeout 32 network not allowed - emergency call only Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 344 2015-08-03 40 network personalisation PIN required 41 network personalisation PUK required 42 network subset personalisation PIN required 43 network subset personalisation PUK required 44 service provider personalisation PIN required 45 service provider personalisation PUK required 46 corporate personalisation PIN required 47 corporate personalisation PUK required 99 resource limitation 100 unknown 103 Illegal MS 106 Illegal ME 107 GPRS services not allowed 111 PLMN not allowed 112 Location area not allowed 113 Roaming not allowed in this location area 132 service option not supported 133 requested service option not subscribed 134 service option temporarily out of order 148 unspecified GPRS error 149 PDP authentication failure 150 invalid mobile class 160 DNS resolve failed 161 Socket open failed 171 MMS task is busy now 172 The MMS data is oversize 173 The operation is overtime 174 There is no MMS receiver 175 The storage for address is full 176 Not find the address 177 The connection to network is failed 178 Failed to read push message 179 This is not a push message 180 gprs is not attached 181 tcpip stack is busy 182 The MMS storage is full 183 The box is empty 184 failed to save MMS Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 345 2015-08-03 185 It is in edit mode 186 It is not in edit mode 187 No content in the buffer 188 Not find the file 189 Failed to receive MMS 190 Failed to read MMS 191 Not M-Notification.ind 192 The MMS inclosure is full 193 Unknown 600 No Error 601 Unrecognized Command 602 Return Value Error 603 Syntax Error 604 Unspecified Error 605 Data Transfer Already 606 Action Already 607 Not At Cmd 608 Multi Cmd too long 609 Abort Cops 610 No Call Disc 611 BT SAP Undefined 612 BT SAP Not Accessible 613 BT SAP Card Removed 614 AT Not Allowed By Customer 753 missing required cmd parameter 754 invalid SIM command 755 invalid File Id 756 missing required P1/2/3 parameter 757 invalid P1/2/3 parameter 758 missing required command data 759 invalid characters in command data 765 Invalid input value 766 Unsupported mode 767 Operation failed 768 Mux already running 769 Unable to get control 770 SIM network reject 771 Call setup in progress Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 346 2015-08-03 772 SIM powered down 773 SIM file not present 791 Param count not enough 792 Param count beyond 793 Param value range beyond 794 Param type not match 795 Param format invalid 796 Get a null param 797 CFUN state is 0 or 4 19.2 Summary of CMS ERROR Codes Final result code +CMS ERROR: indicates an error related to message service or network. The operation is similar to ERROR result code. None of the following commands in the same Command line is executed. Neither ERROR nor OK result code shall be returned. values used by common messaging commands: Code of Meaning 1 Unassigned(unallocated) number 3 No route to destination 6 Channel unacceptable 8 Operator determined barring 10 Call barred 11 Reserved 16 Normal call clearing 17 User busy 18 No user responding 19 User alerting, no answer 21 Short message transfer rejected 22 Number changed 25 Pre-emption 26 Non-selected user clearing 27 Destination out of service 28 Invalid number format (incomplete number) 29 Facility rejected 30 Response to STATUS ENQUIRY 32 Normal, unspecified Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 347 2015-08-03 34 No circuit/channel available 38 Network out of order 41 Temporary failure 42 Switching equipment Congestion 43 Access information discarded 44 Requested circuit/channel not available 47 Resources unavailable, unspecified 49 Quality of service unavailable 50 Requested facility not subscribed 55 Requested facility not subscribed 57 Bearer capability not authorized 58 Bearer capability not presently available 63 Service or option not available, unspecified 65 Bearer service not implemented 68 ACM equal or greater than ACM maximum 69 Requested facility not implemented 70 Only restricted digital information bearer capability is available 79 Service or option not implemented, unspecified 81 Invalid transaction identifier value 87 User not member of CUG 88 Incompatible destination 91 Invalid transit network selection 95 Semantically incorrect message 96 Invalid mandatory information 97 Message type non-existent or not implemented 98 Message type not compatible with protocol state 99 Information element non-existent or not implemented 100 Conditional information element error 101 Message not compatible with protocol 102 Recovery on timer expiry 111 Protocol error, unspecified 127 Interworking, unspecified 128 Telematic interworking not supported 129 Short message Type 0 not supported 130 Cannot replace short message Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 348 2015-08-03 143 Unspecified TP-PID error 144 Data coding scheme (alphabet) not supported 145 Message class not supported 159 Unspecified TP-DCS error 160 Command cannot be acted 161 Command unsupported 175 Unspecified TP-Command error 176 TPDU not supported 192 SC busy 193 No SC subscription 194 SC system failure 195 Invalid SME address 196 Destination SME barred 197 SM Rejected-Duplicate SM 198 TP-VPF not supported 199 TP-VP not supported 208 SIM SMS storage full 209 No SMS storage capability in SIM 210 Error in MS 211 Memory Capacity Exceeded 212 SIM Application Toolkit Busy 213 SIM data download error 224 CP retry exceed 225 RP trim timeout 226 SMS connection broken 255 Unspecified error cause 300 ME failure 301 SMS reserved 302 operation not allowed 303 operation not supported 304 invalid PDU mode 305 invalid text mode 310 SIM not inserted 311 SIM pin necessary 312 PH SIM pin necessary 313 SIM failure Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 349 2015-08-03 314 SIM busy 315 SIM wrong 316 SIM PUK required 317 SIM PIN2 required 318 SIM PUK2 required 320 memory failure 321 invalid memory index 322 memory full 323 invalid input parameter 324 invalid input format 325 invalid input value 330 SMSC address unknown 331 no network 332 network timeout 340 no cnma ack 500 Unknown 512 SMS no error 513 Message length exceeds maximum length 514 Invalid request parameters 515 ME storage failure 516 Invalid bearer service 517 Invalid service mode 518 Invalid storage type 519 Invalid message format 520 Too many MO concatenated messages 521 SMSAL not ready 522 SMSAL no more service 523 Not support TP-Status-Report & TP-Command in storage 524 Reserved MTI 525 No free entity in RL layer 526 The port number is already registerred 527 There is no free entity for port number 528 More Message to Send state error 529 MO SMS is not allow 530 GPRS is suspended 531 ME storage full 532 Doing SIM refresh Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 350 2015-08-03 19.3 Summary of Unsolicited Result Codes URC Description AT Command +CCWA: ,,[,] Indication of a call that is currently waiting and can be accepted. AT+CCWA=1 +CLIP: ,,, ,, The calling line identity (CLI) of the calling party when receiving a mobile terminated call. AT+CLIP=1 +CRING: Indicates incoming call to the TE if extended format is enabled. AT+CRC=1 +CREG: [,,] There is a change in the MT network registration status or a change of the network cell. AT+CREG= +CCWV Shortly before the ACM (Accumulated Call Meter) maximum value is reached. The warning is issued approximately when 5 seconds call time remains. It is also issued when starting a call if less than 5 s call time remains. AT+CCWE=1 +CMTI: , Indicates that new message has been received. AT+CNMI =1 +CMTI: ,,"MMS PUSH" Indicates that new MMS message has been received. AT+CNMI =1 +CMT: Indicates that new message has been received. AT+CNMI =2 (PDU mode) +CMT: ,[,,,,,,, ] Indicates that new message has been received. AT+CNMI =2 (text mode) +CBM: Indicates that new cell broadcast message has been received. AT+CNMI =2 (PDU mode enabled): +CBM: ,,,,Indicates that new cell broadcast message has been received. AT+CNMI =2 (text mode enabled): +CDS: Indicates that new SMS status report has been received. AT+CNMI =1 (PDU mode enabled): Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 351 2015-08-03 +CDS: ,[,][,],,, Indicates that new SMS status report has been received. AT+CNMI =1 (text mode enabled): +COLP: ,[, ,,] The presentation of the COL (Connected Line) at the TE for a mobile originated call. AT+COLP=1 +CSSU: Presentation status during a mobile terminated call setup or during a call, or when a forward check supplementary service notification is received. AT+CSSN=[,< m>]=1 +CSSI: [,] Presentation status after a mobile originated call setup AT+CSSN=[,< m>]=1 +CLCC: ,,,,< mpty>[,,<type,] [+CLCC: ,,,,< mpty> [,,,<alphaID ][...]] Report a list of current calls of ME automatically when the current call status changes. AT+CLCC=1 *PSNWID: "", "", "",, "", Refresh network name by network. *PSUTTZ: ,,,<hour ,,, "", Refresh time and time zone by network. +CTZV: "" Refresh network time zone by network. DST: Refresh Network Daylight Saving Time by network. AT+CLTS=1 +CSMINS: , Indicates whether SIM card has been inserted. AT+CSMINS=1 +CDRIND: Indicates whether a CS voice call, CS data has been terminated. AT+CDRIND=1 +CHF: Indicates the current channel. AT+CHF=1 +CENG: ,",,, ,,,<cellid ,,,," Report of network information. AT+CENG=[,] =2 MO RING Shows call state of mobile originated Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 352 2015-08-03 call: the call is alerted. AT+MORING=1 MO CONNECTED Shows call state of mobile originated call: the call is established. AT+MORING=1 +CPIN: Indicates whether some password is required or not. +CPIN: NOT READY SIM Card is not ready. +CPIN: NOT INSERTED SIM Card is not inserted. AT+CPIN +CSQN: , Displays signal strength and channel bit error rate when ,values change. AT+EXUNSOL=" SQ",1 +SIMTONE: 0 The generated tone playing is stopped or completed. AT+SIMTONE +STTONE: 0 The SIM Toolkit tone playing is stopped or completed. AT+STTONE +CR: An intermediate result code is transmitted during connect negotiation when the TA has determined the speed and quality of service to be used, before any error control or data compression reports are transmitted, and before any final result code (e.g. CONNECT) appears. AT+CR=1 +CUSD: [,<str_urc>[,]] Indicates an USSD response from the network, or network initiated operation. AT+CUSD=1 RING An incoming call signal from network is detected. NORMAL POWER DOWN SIM800 is powered down by the PWRKEY pin or AT command “AT+CPOWD=1”. +CMTE: The module temperature is abnormal. Refer to hardware document for details. AT+CMTE=1 UNDER-VOLTAGE POWER DOWN Under-voltage automatic power down. UNDER-VOLTAGE WARNNING under-voltage warning OVER-VOLTAGE POWER DOWN Over-voltage automatic power down. OVER-VOLTAGE WARNNING over-voltage warning CHARGE-ONLY MODE The module is charging by charger. (require hardware support) RDY Power on procedure is completed, and the module is ready to operate at fixed baud rate. (This URC does not appear when auto-bauding function is active). AT+IPR= is not 0 Call Ready Module is powered on and phonebook initialization procedure is over. AT+CIURC=1 SMS Ready Module is powered on and SMS Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 353 2015-08-03 initialization procedure is over. +CFUN: Phone functionality indication (This URC does not appear when auto-bauding function is active). AT+IPR= is not 0 [,]CONNECT OK TCP/ UDP connection is successful AT+CIPSTART CONNECT TCP/UDP connection in channel mode is successful [,]CONNECT FAIL TCP/UDP connection fails AT+CIPSTART [,]ALREADY CONNECT TCP/UDP connection exists AT+CIPSTART [,]SEND OK Data sending is successful [,]CLOSED TCP/UDP connection is closed RECV FROM: : shows remote IP address and port (only in single connection mode) AT+CIPSRIP=1 +IPD, ,<TCP/UDP>: display transfer protocol in IP header to received data or not (only in single connection mode) AT+CIPHEAD AT+CIPSHOWTP +RECEIVE,, Received data from remote client (only in multiple connection mode) REMOTE IP: Remote client connected in +CDNSGIP: 1,,[,] DNS successful AT+CDNSGIP +CDNSGIP:0, DNS failed +PDP: DEACT GPRS is disconnected by network +SAPBR : DEACT The bearer based on IP connection of SIMCom application is deactivated. +HTTPACTION: ,, Indicates HTTP method, Status Code responded by remote server and the length of data got. AT+HTTPACTIO N= +FTPGET:1, FTPGET session AT+FTPGET=1 +FTPPUT:1,1, It is ready to upload data. AT+FTPPUT +FTPPUT:1, FTP return result AT+FTPPUT +FTPDELE:1, FTP delete session AT+FTPDELE +FTPSIZE:1,, FTP size session AT+FTPSIZE +FTPMKD:1, FTP create directory (not supported for all versions) AT+FTPMKD +FTPRMD:1, FTP delete directory (not supported for all versions) AT+FTPRMD +FTPLIST:1, FTP list session (not supported for all AT+FTPLIST Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 354 2015-08-03 versions) +CGREG: [,,] Network Registration Status AT+CGREG= ALARM RING +CALV: Indicate expired alarm. AT+CALA=<time [,[,]] Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 355 2015-08-03 20 AT Commands Examples 20.1 Profile Commands Demonstration Syntax Expect Result The AT Command interpreter actively responds to input. AT OK Display the product name and the product release information. ATI SIM800 R11.08 OK Display product identification information: the manufacturer, the product name and the product revision information. AT+GSV SIMCOM_Ltd SIMCOM_SIM800H Revision: 1308B01SIM800H32 OK Display current configuration, a list of the current active profile parameters. AT&V [A complete listing of the active profile] OK Reporting of mobile equipment errors. The default CME error reporting setting is disabled. Switch to verbose mode Displays a string explaining the error in more details. AT+CMEE=? AT+CMEE? AT+CSCS=? AT+CSCS="TEST" AT+CMEE=2 AT+CSCS="TEST" +CMEE: (0-2) OK +CMEE: 1 OK +CSCS: ("IRA","GSM","UCS2","HE X","PCCP","PCDN","8859- 1") OK ERROR OK +CME ERROR: invalid input value Store the current configuration in nonvolatile memory. When the board is reset, the configuration changes from the last session are loaded. ATE0&W AT [Reset the board] AT OK [No echo] OK [No echo] OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 356 2015-08-03 ATE1&W AT [No echo] OK [Echo on] OK Set the ME to minimum functionality AT+IPR? AT+CFUN=0 AT+IPR = 115200 AT+IPR? AT+CFUN=0 +IPR:0 OK OK +CPIN: NOT READY OK +IPR:115200 OK OK +CPIN: NOT READY ME has entered full functionality mode AT+CFUN? +CFUN:1 OK 20.2 SIM Commands Demonstration Syntax Expect Result List available phonebooks, and select the SIM phonebook. AT+CPBS=? AT+CPBS="SM" +CPBS: ("SM","ME","ON","FD") OK OK Display the ranges of phonebook entries and list the contents of the phonebook. AT+CPBR=? AT+CPBR=1,10 +CPBR: (1-250),40,14 OK [a listing of phonebook contents] OK Write an entry to the current phonebook. AT+CPBW=,"13 918 18xxxx",129,"Da niel" AT+CPBR=1,10 OK [a listing of phonebook contents] OK Find an entry in the AT+CPBF="Dani +CPBF:5, "13918186089",129,"Daniel" Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 357 2015-08-03 current phonebook using a text search. el" OK Delete an entry from the current phonebook specified by its position index. AT+CPBW=2 AT+CPBR=1,10 OK [a listing of phonebook contents] OK Switch on engineering mode AT+CENG =1,1 AT+CENG? OK +CENG: 1,1 +CENG: 0,"0081,55,00,460,00,31,f9a1,08,05,1816,255" +CENG: 1,"0014,40,15,f2a1,460,00,1816" +CENG: 2,"0012,27,48,f411,460,00,1816" +CENG: 3,"0565,23,55,f1a1,460,00,1816" +CENG: 4,"0584,19,24,f1a3,460,00,1816" +CENG: 5,"0027,17,13,f412,460,00,1816" +CENG: 6,"0028,15,14,6253,460,00,1823" OK Switch on engineering mode, and activate the URC report of network information AT+CENG =2,1 AT+CENG? OK +CENG: 2,1 +CENG: 0,"0081,55,00,460,00,31,f9a1,08,05,1816,255" +CENG: 1,"0014,42,15,f2a1,460,00,1816" +CENG: 2,"0012,25,48,f411,460,00,1816" +CENG: 3,"0565,21,55,f1a1,460,00,1816" +CENG: 4,"0584,19,24,f1a3,460,00,1816" +CENG: 5,"0027,17,13,f412,460,00,1816" +CENG: 6,"0028,17,14,6253,460,00,1823" OK Switch on engineering mode, and with limited network information AT+CENG =3,1 AT+CENG? OK +CENG: 3,1 +CENG: 0,"460,00,1816,f9a1,31,56" +CENG: 1,"460,00,1816,f2a1,15,38" +CENG: 2,"460,00,1816,f411,48,26" +CENG: 3,"460,00,1816,f1a3,24,17" +CENG: 4,"460,00,1816,f412,13,16" +CENG: 5,"460,00,1823,6253,14,16" +CENG: 6,"460,00,1816,f2c3,43,14" Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 358 2015-08-03 OK Switch on engineering mode, and with extern information AT+CENG =4,1 AT+CENG? OK +CENG: 4,1 //Dedicated mode: +CENG: 0,"0081,47,00,460,00,31,f9a1,08,05,1816,00,-66,0, 0,64,7,64,0,0,0,EFR" //Idle mode: +CENG: 0,"0081,56,00,460,00,31,f9a1,08,05,1816,255,-57, 177,617,x,x,x,x,x,x" +CENG: 1,"0014,35,15,f2a1,460,00,1816,91,531" +CENG: 2,"0012,25,48,f411,460,00,1816,51,491" +CENG: 3,"0565,24,55,f1a1,460,00,1816,45,485" +CENG: 4,"0027,20,13,f412,460,00,1816,31,471" +CENG: 5,"0584,20,24,f1a3,460,00,1816,29,469" +CENG: 6,"0028,16,14,6253,460,00,1823,18,455" OK 20.3 General Commands Demonstration Syntax Expect Result Display the current network operator that the handset is currently registered with. AT+COPS? +COPS: 0,0,"CHINA MOBILE" OK Display a full list of network operator names. AT+COPN +COPN: "20201", "COSMO" [skip a bit] +COPN: "901012","Maritime Comm Partner AS" OK reduce its functionality. This will deregister the handset from the network. AT+IPR? AT+CFUN=0 [wait for deregister] ATD6241xxxx; AT+CFUN=1 +IPR: 0 OK OK ERROR OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 359 2015-08-03 Request the IMSI AT+CIMI 460008184101641 OK 20.4 Call Control Commands Demonstration Syntax Expect Result Make a voice call ATD6241xxxx; OK MS makes a voice call Hang up a call ATH OK Call dropped Make a voice call using the last number facility. The initial call is established and then cancelled. The second call is made using the previous dial string. ATD6241xxxx; ATH ATDL OK OK OK Example of a MT voice call Make MT voice call to MS. ATA ATH RING RING OK[accept call] OK[hang up call] Call related to supplementary service: AT+CHLD. This Command provides support for call waiting functionality. AT+CHLD= Return value:(0,1,1x,2,2x,3,4) Terminate current call and accept waiting call. Establish a voice call from EVB, receive an incoming call (incoming call accepts waiting status), terminate active call and accept incoming call. Note call waiting must be active for this option – use "AT+CCWA=1,1” before running this demonstration. AT+CCWA=1,1 ATD6241xxxx;AT+CHLD=1 OK OK RING +CCWA: "62418148 ", 129,1,"" OK Set current call to busy state and accept waiting call. Establish a voice call from EVB, receive an incoming call (incoming call accepts waiting status), place active call on hold and switch to incoming call. Terminate active call and switch back to original call. Note call waiting must have been previously enabled for this demonstration to work. ATD6241xxxx; AT+CHLD=2 AT+CHLD=1 RING +CCWA: "1391818 6089",129,1,"" OK OK <incoming call terminated, dialed number now active> Switch between active and held calls. Establish a voice call from EVB, receive ATD6241xxxx; OK RING Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 360 2015-08-03 an incoming call (incoming call accepts waiting status), place active call on hold and switch to incoming call. Switch between both calls, placing each in the hold state whilst the other is active before terminating each one. This feature relies on knowing each call’s ID. This is done using the List Current Calls (AT+CLCC) Command. A call’s ID is required to switch between held and active calls. Held calls are not automatically resumed when all other calls are terminated. They need to be made active using the AT+CHLD=2x Command. Note call waiting must have been previously enabled for this demonstration to work. AT+CHLD=2 AT+CHLD=21 AT+CLCC AT+CHLD=22 AT+CHLD=12 AT+CHLD=11 +CCWA: "1391818 6089",129,1,"" OK <incoming call activated, original on hold> OK <original call activated, incoming call held> +CLCC:1,0,0,0,0,"62 418148",129,"" +CLCC:2,1,1,0,0, "139 18186089",129, "" OK OK <original call held, incoming call active> OK Send busy status to incoming waiting caller. Establish a voice call from EVB, receive an incoming call (incoming call accepts waiting status), send ‘busy’ status to waiting mobile. Note call waiting must have been previously enabled for this demonstration to work. ATD6241xxxx; AT+CHLD=0 OK RING +CCWA: "1391818 6089",129,1,"" OK OK <incoming call sent busy msg, current call retained> Drop all calls on hold. Establish a voice call from EVB, receive an incoming call (incoming call accepts waiting status), switch to incoming call and drop all waiting calls. Note call waiting must have been previously enabled for this demonstration to work. ATD6241xxxx; AT+CHLD=2 AT+CHLD=0 OK RING +CCWA: "1391818 6089",129,1,"" OK <incoming call actived, original on hold> OK <incoming call actived, current call terminate> Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 361 2015-08-03 20.5 SIM Toolkit Commands Please refer to SIM800 Series_STK_Application Note.DOC 20.6 Audio Commands Demonstration Syntax Expect Result DTMF tones AT+CLDTMF=2, "1,2,3,4,5" OK AT+CLDTMF=2,”A,B ,C,D,E,F”,50 OK 20.7 SMS Commands Demonstration Syntax Expect Result Set SMS system into text mode, as opposed to PDU mode. AT+CMGF=1 OK Send an SMS to myself. AT+CSCS="GSM" AT+CMGS="+861391 818xxxx"This is a test <Ctrl+Z> OK +CMGS:34 OK Unsolicited notification of the SMS arriving +CMTI: "SM",1 Read SMS message that has just arrived. Note: the number should be the same as that given in the +CMTI notification. AT+CMGR=1 +CMGR: "REC UNREAD", "+8613918186089", "","02 /01/30,20:40:31+00" This is a test OK Reading the message again and change the status to "READ” from ”UNREAD” AT+CMGR=1 +CMGR: "REC READ", "+8613918186089","", "02/01/30,20:40:31+00" This is a test OK Send another SMS to myself. AT+CMGS="+861391 818xxxx" Test again<Ctrl+Z> +CMGS:35 OK Unsolicited notification of the SMS arriving +CMTI: "SM",2 List all SMS messages. AT+CMGL="ALL" +CMGL: 1, "REC Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 362 2015-08-03 Note:”ALL” must be in uppercase. READ","+8613918186089", "", "02/01/30,20:40:31+00" This is a test +CMGL: 2, "REC UNREAD"," ", "+8613918186089", "" ,"02/01/30,20:45:12+00" Test again OK Delete an SMS message. AT+CMGD=1 OK List all SMS messages to show message has been deleted. AT+CMGL="ALL" +CMGL: 2, "REC READ", "+8613918186 089","","02/01/30,20:45:12+ 00" Test again OK Send SMS using Chinese characters AT+CSMP=17,167,2, 25 AT+CSCS="UCS2" AT+CMGS="0031003 300390031003800310 038003x003x003x003 x" 4E014E50<Ctrl+Z> OK OK +CMGS:36 OK 20.8 GPRS Commands Demonstration Syntax Expect Result Establish a GPRS context. Setup modem driver Setup dial up connection with *99# Run internet explorer Should be able to surf the web using Internet explorer. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 363 2015-08-03 There are two GPRS Service Codes for the ATD Command: Value 88 and 99. Establish a connection by service codeEstablish a connection by service code 99 and using CID 1 ATD99# ATD991# CONNECT CONNECT Check if the MS is connected to the GPRS network Detach from the GPRS network Check if the MS is connected to the GPRS network AT+CGATT? AT+CGATT=0 AT+CGATT? +CGATT:1 OK OK +CGATT: 0 OK Check the class of the MS AT+CGCLASS? +CGCLASS:B OK Establish a context using the terminal equipment: defines CID 1 and sets the PDP type to IP, access point name and IP address aren’t set. AT+CGDCONT=1, "IP","CMNET" ATD99# OK CONNECT Cancel a context using the terminal equipment Pause data transfer and enter Command mode by +++ Stop the GPRS data transfer AT+CGDCONT=1, "IP","CMNET" ATD99# +++ ATH OK CONNECT OK OK Reconnect a context using the terminal equipment Resume the data transfer AT+CGDCONT=1, "IP","CMNET" ATD99# +++ ATO OK CONNECT OK CONNECT Quality of Service (QOS) is a special parameter of a CID which consists of several parameters itself. The QOS consists of The precedence class The delay class The reliability class Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 364 2015-08-03 The peak throughput class The mean throughput class And is decided in "requested QOS” and "minimum acceptable QOS”. All parameters of the QOS are initiated by default value (=0) except the reliability class is 3. To define a QOS use the AT+CGQREQ or AT+CGQMIN Command. Overwrite the precedence class of QOS of CID 1 and sets the QOS of CID 1 to be present AT+CGQREQ=1,0,0,3 ,0,0 OK Response: all QOS values of the activated CID. AT+CGQREQ? +CGQREQ: 1,0,0,3,0,0 +CGQREQ: 2,0,0,3,0,0 +CGQREQ: 3,0,0,3,0,0 OK Set the QOS of CID 1 to not present. Once defined, the CID can be activated. AT+CGQREQ=1 OK Activate CID 1, if the CID is already active, the mobile returns OK at once. If no CID is defined the mobile responds +CME ERROR: invalid index. Note: If the mobile is NOT attached by AT+CGATT=1 before activating, the attachment is automatically done by the AT+CGACT Command. AT+CGACT=1,1 AT+CGACT=1,3 OK +CME ERROR: requested service option not subscribed. Use the defined and activated CID to get online. The mobile can be connected using the parameters of appointed CID or using default parameter AT+CGDATA="PPP", 1 CONNECT The mobile supports Layer 2 Protocol (L2P) PPP only. Note: If the mobile is NOT attached by AT+CGATT=1 and the CID is NOT activated before connecting, attaching and activating is automatically done by the AT+CGDATA Command. Some providers require using an APN to establish a GPRS connection. So if user uses the Microsoft Windows Dial-Up Network and ATD9… to connect to GPRS, user must provide the context definition as part of the modem definition (Modem properties/Connection/Advanced… /Extra settings.) As an alternative, user can define and activate the context in a terminal program (e.g. Microsoft HyperTerminal) and then use the Dial-Up Network to send only the ATD Command. 20.9 TCPIP Commands Please refer to SIM800 Series_TCPIP_Application Note.doc Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 365 2015-08-03 20.10 IP Commands Please refer to SIM800 Series_IP_Application Note.doc. Chapter 3.1 describles how to config bearer contexts of HTTP and FTP applications. 20.11 PING Commands Demonstration Syntax Expect Result Ping Request AT+CGATT? AT+CSTT=”CMNET” AT+CIICR AT+CIFSR AT+CIPPING="www. google.cn" +CGATT: 1 OK OK OK 10.78.245.128 +CIPPING:1,"203.208.37.99 ",70,239 +CIPPING:2,"203.208.37.99 ",53,238 +CIPPING:3,"203.208.37.99 ",60,239 +CIPPING:4,"203.208.37.99 ",50,239 OK Other Device Ping To The Module On the Modem: AT+CGATT? AT+CSTT=”CMNET” AT+CIPBEIPING=1 (If on 6252 platform, don’t need this at) AT+CIICR AT+CIFSR On the Other Device: AT+CIPPING="10.78. On the Modem: +CGATT: 1 OK OK OK OK 10.78.245.128 On the Other Device: +CIPPING:1,"10.78.25.18",7 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 366 2015-08-03 25.18" 0,239 +CIPPING:2,"10.78.25.18",5 3,238 +CIPPING:3,"10.78.25.18",6 0,239 +CIPPING:4,"10.78.25.18",5 0,239 OK IP Filter Setting AT+CIPFLT=1,1, "198.211.19.12","255. 255.0.0" AT+CIPFLT=1,, "10.43.21.69","255.0.0 .0” AT+CIPFLT=0,1 AT+CIPFLT=2 OK OK OK OK Set the Mode When Receiving an IP Packet AT+CIPCTL=0 AT+CIPCTL=1 AT+CIPCTL=2 OK OK OK 20.12 HTTP and FTP Commands Please refer to SIM800 Series_IP_Application Note.doc 20.13 GSM Location Commands Demonstration Syntax Expect Result Activate bearer profile AT+SAPBR=3,1,"Con type","GPRS" AT+SAPBR=3,1,"AP N","CMNET" AT+SAPBR =1,1 AT+SAPBR=2,1 OK OK OK +SAPBR: 1,1,"10.89.193.1" OK Get location AT+CIPGSMLOC=1, +CIPGSMLOC: Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 367 2015-08-03 1 AT+CIPGSMLOC=2, 1 0,121.354848,31.221402,201 1/01/26,02:41:06 OK +CIPGSMLOC: 0,2011/01/26,03:12:58 OK Deactivate bearer profile AT+SAPBR=0,1 OK 20.14 EMAIL Commands Please refer to SIM800 Series_Email_Application Note.doc. 20.15 MMS Commands Demonstration Syntax Expect Result Initialization AT+CMMSINIT OK Configuration AT+CMMSCURL=“m msc.monternet.com” AT+CMMSCID=1 AT+CMMSPROTO=“ 10.0.0.172”,80 AT+CMMSSENDCF G=6,3,0,0,2,4 OK OK OK OK Active bearer profile AT+SAPBR=3,1,"Con type","GPRS" AT+SAPBR=3,1,"AP N","CMWAP" AT+SAPBR=1,1 AT+SAPBR=2,1 OK OK OK +SAPBR: 1,1,"10.89.193.1" OK Send MMS AT+CMMSEDIT=1 AT+CMMSDOWN=“ PIC”,12963,20000 OK CONNECT ... ... OK Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 368 2015-08-03 AT+CMMSDOWN=“ TITLE”,3,5000 AT+CMMSRECP=“1 3918181818” AT+CMMSSEND CONNECT ... ... OK OK …… OK Receive MMS When received a MMS push message,UART will output message,such as “+CMTI: "SM",3,"MMS PUSH"” AT+CMMSEDIT=0 AT+CMMSRECV=3 AT+CMGD=3 OK +CMMSRECV: "+8613818181818", "2008-05-02, 03:38:12","", 26670 1, "image0.jpg",7,26625 OK OK Receive MMS when the MMS push message is a concatenated message. UART output messages: +CMTI: "SM",1,"MMS PUSH",2,1 +CMTI: "SM",2,"MMS PUSH",2,2 +CMTI: "SM",1,"MMS PUSH" AT+CMMSEDIT=0 AT+CMMSRECV=1 AT+CMGD=1 OK +CMMSRECV: "+85266097746","2009-04-1 5,10:41:21","",49 1,"text0.txt",4,7 OK OK Read a file of MMS AT+CMMSREAD=1 +CMMSREAD: "image0.jpg", 26625 …… OK Exit MMS function AT+CMMSTERM OK 20.16 DDET Commands Demonstration Syntax Expect Result enable DTMF detection AT+DDET=1,0,0 //start DDET, interval is 0, report mode is 0 OK Set up a call connection ATD*********; OK If module detected DTMF, URC will be reported via serial port Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 369 2015-08-03 +DTMF:1 //report DTMF value +DTMF:2 +DTMF:3 Receive an incoming call ATA OK If module detected DTMF, URC will be reported via serial port +DTMF:1 //report DTMF value +DTMF:2 +DTMF:3 +DTMF:4 enable DTMF detection AT+DDET=1,1000,1 //start DDET, interval is 1000ms, report mode is 1 OK Set up a call connection ATD***********; OK If module detected DTMF, URC will be reported via serial port, the minimal interval between two identic DTMF is 1000ms. +DTMF:1,160 //report DTMF value and last time +DTMF:2,300 +DTMF:3,200 Receive an incoming call ATA OK If module detected DTMF, URC will be reported via serial port +DTMF:1,160 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 370 2015-08-03 //report DTMF value and last time +DTMF:2,300 +DTMF:3,200 20.17 RECORD Commands Demonstration Syntax Expect Result Start record AT+CREC=1,1,0 //start record OK // the record id is 1, format is AMR Stop record AT+CREC=2 //stop record OK +CREC: 2,1,0,15,16386 //URC will be reported after stopping, which indicate the format,including record id, time in seconds, length in bytes Delete record AT+CREC=3,1 //delete record with id 1 OK Play record file AT+CREC=4,1,0,80 //play record file, channel is 0, the volume is 80 OK Stop play record file AT+CREC=5 //stop play record file +CREC: 0 OK //URC is reported to show statues IDLE Get record status AT+CREC? //get record status +CREC:2 OK //Rrecording ,delete and other play operations are not allowed when playing List record file information AT+CREC=7 //list record file list +CREC: 7,1,7728,0 +CREC: 7,2,53820,1 OK // two record file, one Is Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 371 2015-08-03 Get record file data AT+CREC=6,1,200,0 //get 200 bytes from record file with offset 0 to file head +CREC: 6,1,200 2321414D520A04923231D8 28E7B0E222B6D0B604941 AEC23377C8A442AFC934 40450E0133334D31577CB8 E88FE0450A54AD57AC23 086C24529FC0422434276A B0E88DCF481E23A0419F0 50336489D54CB57224B004 2119466B5B5521D542FF35 4204C0422385A00B20DBC 67DC322049D87084889706 30CECBFE40004C0892EF5 914BD62A234C0B5804334 110F8818197ECA9D7F02E 046EDAD5EBA75928D948 FBB19E046EAF1C3A90168 351C302DF8804460C1409B 18966E0187F88B404CA88F 4F891BFE72BCF45D7 OK //data in Hex format Query free space AT+CREC=8 //query free memory space +CREC: 8,938600 OK //the free memory space is 938600 bytes Create record file directory AT+CREC=9,0 //create record file directory on system FAT OK 20.18 TTS Commands Demonstration Syntax Expect Result Play synthetic speech with UCS2 coding text AT+CTTS=1,"6B228F CE4F7F75288BED97 F3540862107CFB7E DF" // text in UCS2 coding format,context of the text is “欢迎使用语音 OK //speech synthetized successfully, played locally. +CTTS:0 //speech played over Note: User needs to wait thisresponse to play next Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 372 2015-08-03 合成系统”. speech! Play synthetic speech with ASCII coding text AT+CTTS=2,"hello , 欢迎使用语音合成系 统" // text in ASIIC coding format.Chinese in GBK coding format. OK //speech synthetized Successfully played locally. +CTTS:0 //speech played over. Note: User needs to wait thisresponse to play next speech! Stop playing TTS AT+CTTS=0 //Stop playing synthetic speech OK //speech played over. Set parameters of the TTS playing AT+CTTSPARAM=5 0, 0,50,25,1 // set params of the TTS playing OK // set params over. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 373 2015-08-03 21 ATC Differences among SIM800 Series 21.1 AT+SIDET SIM800V, SIM840V,SIM800W, SIM840W,SIM800W16,SIM840W16 SIM800H,SIM800L,SIM800,SIM800M64, SIM808,SIM800C,SIM800A,SIM800F, SIM800C-DS AT+SIDET=? +SIDET: (0,1),(0-16) OK AT+SIDET=? If it is SIM800, SIM800M64,SIM800C, SIM800A,SIM800F +SIDET: (0, 2 ),(0-16) OK If it is SIM800H, SIM800L, SIM808 or SIM800C-DS +SIDET: (0-3),(0-16) OK Difference: 21.2 AT+CMIC SIM800V, SIM840V,SIM800W, SIM840W,SIM800W16,SIM840W16 SIM800H,SIM800L,SIM800,SIM800M64, SIM808,SIM800C,SIM800A,SIM800F, SIM800C-DS AT+CMIC=? +CMIC: (0,1),(0-15) OK AT+CMIC=? If it is SIM800, SIM800M64,SIM800C, SIM800A,SIM800F +CMIC: (0, 2 ),(0-15) OK If it is SIM800H, SIM800L, SIM808 or SIM800C-DS +CMIC: (0-3),(0-15) OK Difference: The default gain level of main audio channel is 10. The default gain level of aux audio channel is 11 in SIM800H, SIM800L, SIM808 and Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 374 2015-08-03 SIM800C-DS. The default gain level of aux audio channel is 9 in SIM800V, SIM840V, SIM800W, SIM840W, SIM800W16 and SIM840W16. The default gain level of aux audio channel is 8 in SIM800C, SIM800A and SIM800F. 21.3 AT+CBAND SIM800V, SIM800W,SIM800W16,SIM800A SIM840V,SIM840W,SIM840W16,SIM800H,SI M800L, SIM800,SIM800M64,SIM800G, SIM808,SIM800C,SIM800F,SIM800C-DS AT+CBAND=? +CBAND: (EGSM_MODE,DCS_MODE,EGSM_DCS _MODE,ALL_BAND) OK AT+CBAND=? +CBAND: (EGSM_MODE,DCS_MODE,GSM850_MOD E,PCS_MODE,EGSM_DCS_MODE,GSM850 _PCS_MODE,EGSM_PCS_MODE,ALL_BAN D) OK Difference: SIM840V, SIM840W, SIM840W16,SIM800H, SIM800L, SIM800, SIM800M64, SIM800G, SIM808, SIM800C, SIM800F and SIM800C-DS support Quad-band. 21.4 AT+CHFA SIM800V, SIM840V,SIM800W, SIM840W,SIM800W16,SIM840W16 SIM800H,SIM800L,SIM800,SIM800M64, SIM808,SIM800C,SIM800A AT+CHFA=? +CHFA: (0 = NORMAL_AUDIO, 1 = AUX_AUDIO) OK AT+CHFA=? If it is SIM800 and SIM800M64 +CHFA: (0 = NORMAL_AUDIO, 2 = HANDFREE_AUDIO,4=PCM_AUDIO) OK If it is SIM800H,SIM800L, SIM808 or SIM800C-DS +CHFA: (0 = NORMAL_AUDIO, 1 = AUX_AUDIO, 2 = HANDFREE_AUDIO, 3 = AUX_HANDFREE_AUDIO, 4 = PCM_AUDIO) OK If it is SIM800C,SIM800A,SIM800F +CHFA: (0 = NORMAL_AUDIO, 2 = Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 375 2015-08-03 HANDFREE_AUDIO) OK Difference: In SIM800H, SIM800L, SIM808 and SIM800C-DS, channel 2 is the same with channel 0, channel 3 is the same with channel 1.channel 4 is multiplexed. SIM800G can not support this AT command. 21.5 AT+SGPIO SIM800V, SIM840V,SIM800W, SIM840W,SIM800W16,SIM840W16 SIM800H,SIM800L,SIM800, SIM808,SIM800M64 AT+SGPIO=? +SGPIO: (0-1),(1-11),(0-1),(0-1) OK AT+SGPIO=? +SGPIO: (0-1),(1-7),(0-1),(0-1) OK Difference: GPIO4 and GPIO5 only support the read operation in SIM800H, SIM800L, SIM800, SIM800M64 and SIM808. SIM800, SIM800M64 and SIM808 do not support GPIO1. SIM800G and SIM800C, SIM800A, SIM800F and SIM800C-DS can not support this command. 21.6 AT+SJDR Jamming detection PIN takes effect only in SIM800H, SIM800L, SIM800, SIM800M64, SIM808, SIM800C, SIM800A, SIM800F and SIM800C-DS.The Jamming detection PIN is defined as follows. Module Type Jamming detection PIN SIM800H/SIM800L PIN5 SIM800/SIM800M64 PIN67 SIM808 PIN63 SIM800C PIN29 SIM800A PIN67 SIM800F PIN67 SIm800C-DS PIN29 SIM800V, SIM840V, SIM800W, SIM840W, SIM800W16 and SIM840W16 have no jamming detection PIN to indicate JD status, only report jamming status via URC from serial port. Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 376 2015-08-03 21.7 AT+CREC Play in call support AMR format in SIM800H, SIM800, SIM800M64, SIM808, SIM800C, SIM800A, SIM800F and SIM800C-DS. The value of parameter is only "0" in SIM800 and SIM800M64. 21.8 AT+CTTSPARAM SIM800V,SIM840V, SIM800W, SIM840W,SIM800W16,SIM840W16 SIM800H,SIM800,SIM800M64 AT+CTTSPARAM? +CTTSPARAM: 50,0,50,50,1 OK AT+CTTSPARAM? +CTTSPARAM: 50,0,50,50,0 OK Difference: Default value of output channel is different. 21.9 AT+CADC SIM800V, SIM840V,SIM800W,SIM840W, SIM800W16,SIM840W16,SIM800H, SIM800L,SIM800,SIM800M64,SIM800C, SIM800A,SIM800F,SIM800C-DS SIM808 AT+CADC? +CADC: 1,603 OK AT+CADC? +CADC: 1,958 +CADC: 1,2223 OK Difference: SIM808 has two ADC channels and others have only one ADC channel. 21.10 AT+CSCLK SIM800V, SIM840V,SIM800W,SIM840W, SIM800W16,SIM840W16,SIM800H, SIM800L,SIM800,SIM800M64,SIM800C, SIM800A,SIM800F,SIM800C-DS SIM808 AT+CSCLK=? +CSCLK: (0-2) AT+CSCLK=? +CSCLK: (0-1) Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 377 2015-08-03 OK OK Difference: SIM808 does not support AT+CSCLK=2. 21.11 AT+CMMSDOWN SIM800V, SIM840V, SIM800W, SIM840W, SIM800W16,SIM840W16,SIM800L,SIM80 0H, SIM800, SIM800M64, SIM800G, SIM800C-DS SIM808,SIM800C,SIM800A,SIM800F AT+SGPIO=? +CMMSDOWN: "PIC", (1-307200), (5000-),"NAME" +CMMSDOWN: "TEXT", (1-15360), (2000-),"NAME" +CMMSDOWN: "TITLE", (1-40), (2000-) OK AT+CMMSDOWN=? +CMMSDOWN: "PIC", (1-307200), (5000-),"NAME" +CMMSDOWN: "TEXT", (1-15360), (2000-),"NAME" +CMMSDOWN: "TITLE", (1-40), (2000-) +CMMSDOWN: "AUDIO_ACC", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_AMR", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_BASIC", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_MID", (1-307200), (5000-),"NAME" +CMMSDOWN: "AUDIO_MPEG", (1-307200), (5000-),"NAME" +CMMSDOWN: "VIDEO_3GPP", (1-307200), (5000-),"NAME" +CMMSDOWN: " VIDEO _MP4", (1-307200), (5000-),"NAME" OK 21.12 AT+CFGRI SIM800V, SIM840V, SIM800W, SIM840W, SIM800W16,SIM840W16,SIM800L,SIM80 0H, SIM800, SIM800M64, SIM800G, SIM800C-DS SIM808, SIM800C, SIM800A, SIM800F AT+CFGRI? +CFGRI: 0 AT+CFGRI? +CFGRI: 2 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 378 2015-08-03 OK OK Difference: Default value is different. 21.13 Only Part of Projects Support Following AT Commands Chapter AT command or function Supported by project 2.2.5 ATD> SIM800V, SIM840V, SIM800W, SIM840W, SIM800W16, SIM840W16, SIM800L, SIM800H, SIM800, SIM800M64, SIM800G, SIM808, SIM800C, SIM800A, SIM800F 2.2.39 AT+ICF SIM800V,SIM840V,SIM800W,SIM840W,SIM800W16, SIM840W16,SIM800L,SIM800H,SIM800, SIM800M64,SIM800G,SIM808 3.2.4 AT+CBST SIM800V,SIM840V,SIM800W,SIM840W,SIM800W16, SIM840W16,SIM800L,SIM800H,SIM800, SIM800M64,SIM800G,SIM808 6.2.10 AT+CMOD SIM800V,SIM840V,SIM800W,SIM840W,SIM800W16, SIM840W16,SIM800L,SIM800H,SIM800, SIM800M64,SIM800G,SIM808 6.2.40 AT+SGPIO SIM800V,SIM840V,SIM800W,SIM840W,SIM800W16, SIM840W16,SIM800L,SIM800H,SIM800, SIM800M64,SIM800G,SIM808 6.2.41 AT+SPWM SIM800V,SIM840V,SIM800W,SIM840W,SIM800W16, SIM840W16,SIM800L,SIM800H,SIM800, SIM800M64,SIM800G,SIM808 6.2.59 AT+CPCMCFG SIM800H,SIM800L,SIM800,SIM800M64,SIM808 6.2.60 AT+CPCMSYNC SIM800H,SIM800L,SIM800, SIM800M64,SIM808 6.2.61 AT+CANT SIM800H,SIM800L,SIM800, SIM800M64,SIM808,SIM800C,SIM800A,SIM800F 6.2.63 AT+SD2PCM SIM800H,SIM800L,SIM800, SIM800M64,SIM808 6.2.64 AT+SKPD SIM800H,SIM800L,SIM800, SIM800M64,SIM808 6.2.68 AT+CMNRP SIM800H,SIM800L,SIM800, SIM800M64 6.2.69 AT+CEGPRS SIM800H,SIM800L,SIM800, SIM800M64,SIM800C-DS 6.2.74 AT+ECHARGE SIM808 6.2.75 AT+SIMTIMER SIM800H,SIM800L,SIM800, SIM800G 6.2.76 AT+SPE SIM800H, SIM800L,SIM800, SIM800G 6.2.77 AT+CCONCINDEX SIM808,SIM800C,SIM800A, SIM800F Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 379 2015-08-03 6.2.78 AT+SDMODE SIM808 6.2.79 AT+SRSPT SIM800H,SIM800L,SIM800,SIM800G,SIM808,SIM800 C, SIM800A,SIM800F 10.2.4 AT+CIPBEIPING SIM800H, SIM800L,SIM800, SIM800M64,SIM808, SIM800C,SIM800A,SIM800F,SIM800C-DS 11.2.9 AT+HTTPHEAD SIM800H,SIM800L,SIM800,SIM800G 17 Record function SIM800V, SIM840V, SIM800W, SIM840W, SIM800H, SIM800, SIM800M64, SIM808,SIM800C,SIM800A, SIM800F,SIM800C-DS 18 TTS function SIM800V,SIM840V, SIM800W, SIM840W,SIM800H, SIM800,SIM800M64,SIM800C Note: SIM800H,SIM800 and SIM800C only support Chinese TTS. 19 AT commands of AOC SIM800V,SIM840V,SIM800W,SIM840W,SIM800W16, SIM840W16,SIM800L,SIM800H,SIM800,SIM800M64, SIM800G,SIM808 Smart Machine Smart Decision SIM800 Series_AT Command Manual_V1.09 380 2015-08-03 Contact us: Shanghai SIMCom wireless solutions Ltd. Address: Building A, SIM Technology Building, No. 633 Jinzhong Road, Shanghai, P. R. China 200335 Tel: +86 21 3252 3300 Fax: +86 21 3252 3020 URL: www.sim.com/wm